A new calibration method of an array of plastic scintillating fibers for dosimetry in electron FLASH Radiotherapy

被引:0
|
作者
Ravera, E. [1 ,2 ]
Cavalieri, A. [1 ,2 ]
Ciarrocchi, E. [1 ]
Del Sarto, D. [2 ,4 ,5 ,6 ]
Di Martino, F. [2 ,3 ,4 ]
Massa, M. [2 ]
Masturzo, L. [1 ,3 ,4 ]
Moggi, A. [2 ]
Morrocchi, M. [1 ,2 ]
Pensavalle, J. H. [1 ,3 ,4 ]
Bisogni, M. G. [1 ,2 ,4 ]
机构
[1] Univ Pisa, Dept Phys, Pisa, Italy
[2] Natl Inst Nucl Phys, Sect Pisa, Pisa, Italy
[3] Azienda Univ Osped Pisana, UO Fis Sanit, Pisa, Italy
[4] Ctr Pisano Ricerca & Implementaz Clin Flash Radio, Pisa, Italy
[5] Univ Pisa, Ctr Instrument Sharing Univ Pisa CISUP, Pisa, Italy
[6] SIT Sordina IORT Technol, Aprilia, Italy
关键词
FLASH radiotherapy; Ultra-high dose rate; Dosimetry; Plastic scintillating fiber; Cerenkov radiation; BEAM DOSIMETRY; DETECTORS; RADIATION; PHOTON;
D O I
10.1016/j.radmeas.2024.107254
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The challenge of saturation at the high dose rate employed in FLASH radiotherapy and the lack of realtime 2D and 3D dosimeters create an opportunity for the use of plastic scintillators. This study presents the development of an online dosimetric system designed for electron FLASH radiotherapy applications: an array of dosimeters, made by plastic scintillating fibers, each one coupled to an optical fiber, was evaluated as a proof- of-concept using a LINAC providing 9 MeV electrons, at the Centro Pisano Flash Radiotherapy. Signal linearity was established up to 10 Gy/pulse, with a pulse duration of 4 mu s. We also measured the signal variation across the beam profile using different applicators (30 mm, 50 mm and 100 mm in diameters) and we developed a geometrical model that accounts for the different amount of dose absorbed by the plastic scintillating fibers and the optical fibers. By fitting this model to the data, we estimated both the inter-calibration factors of the dosimeters, as well as the intrinsic ratio (i.e. for equal irradiated volumes) of spurious light in the optical fiber respect to the scintillation, which is equal to (4.7 +/- 0 . 1. +/- 1 . 0 . ) %.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A high DQE water-equivalent EPID employing an array of plastic-scintillating fibers for simultaneous imaging and dosimetry in radiotherapy
    Blake, Samuel J.
    Cheng, Zhangkai
    McNamara, Aimee
    Lu, Minghui
    Vial, Philip
    Kuncic, Zdenka
    MEDICAL PHYSICS, 2018, 45 (05) : 2154 - 2168
  • [2] Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators
    Archambault, L
    Arsenault, J
    Gingras, L
    Beddar, AS
    Roy, R
    Beaulieu, L
    MEDICAL PHYSICS, 2005, 32 (07) : 2271 - 2278
  • [3] Towards a next-generation plastic scintillating fiber array with improved sensitivity for radiotherapy imaging and dosimetry
    Blake, S. J.
    Cheng, Z.
    Atakaramians, S.
    Lu, M.
    Vial, P.
    Kuncic, Z.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [4] Development of a plastic scintillating optical fibers array dosimeter for radiobiology
    Guerreiro, D. R.
    Saraiva, J. G.
    Borges, M. J.
    Sampaio, J. M.
    Peralta, L.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05)
  • [5] A prototype ASIC for APD array readout of scintillating plastic fibers
    Macri, JR
    Wintenberg, A
    Widholm, M
    Jagadish, U
    Ledoux, J
    McConnell, ML
    Frank, SS
    Cutlip, H
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 106 - 110
  • [6] Readout of scintillating plastic fibers with an APD array and prototype ASIC
    Macri, JR
    Wintenberg, AL
    Widholm, M
    Jagadish, U
    Ledoux, J
    McConnell, ML
    Frank, SS
    Cutlip, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 928 - 935
  • [7] Characterization of a commercial plastic scintillator for electron FLASH dosimetry
    Oh, Kyuhak
    Hyun, Megan A.
    Gallagher, Kyle J.
    Yan, Ying
    Zhou, Sumin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [8] Radiation Induced Acoustic Dosimetry of Electron Flash Radiotherapy
    Bjegovic, K.
    Sun, L.
    Pandey, P. K.
    Gonzalez, G.
    Vozenin, M. C.
    Limoli, C.
    Xiang, L.
    MEDICAL PHYSICS, 2024, 51 (10) : 7749 - 7749
  • [9] Alanine/electron spin resonance dosimetry for FLASH radiotherapy
    Gu, Runqiu
    Wang, Jianlin
    Wang, Pan
    Mao, Xin
    Lin, Binwei
    Tan, Wanchao
    Du, Xiaobo
    Gao, Feng
    Wang, Tingting
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [10] FLASH radiotherapy: A promising new method for radiotherapy
    Lv, Yinghao
    Lv, Yue
    Wang, Zhen
    Lan, Tian
    Feng, Xuping
    Chen, Hao
    Zhu, Jiang
    Ma, Xiao
    Du, Jinpeng
    Hou, Guimin
    Liao, Wenwei
    Yuan, Kefei
    Wu, Hong
    ONCOLOGY LETTERS, 2022, 24 (06)