Characterization of a commercial plastic scintillator for electron FLASH dosimetry

被引:0
|
作者
Oh, Kyuhak [1 ]
Hyun, Megan A. [1 ]
Gallagher, Kyle J. [1 ]
Yan, Ying [1 ]
Zhou, Sumin [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE 68198 USA
来源
关键词
dosimetry; electron ultra-high dose rate (eFLASH); FLASH research extension (FLEX); plastic scintillator; BEAM DOSIMETRY; ION RECOMBINATION;
D O I
10.1002/acm2.14451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems.Methods and materialsWe assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film.ResultsWe observed that the 1 x 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 x 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of similar to 1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies.ConclusionsThis study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Characterization of a non-contact imaging scintillator-based dosimetry system for total skin electron therapy
    Tendler, Irwin I.
    Bruza, Petr
    Jermyn, Mike
    Cao, Xu
    Williams, Benjamin B.
    Jarvis, Lesley A.
    Pogue, Brian W.
    Gladstone, David J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [42] Dosimetry with a clinical linac adapted to FLASH electron beams
    Szpala, Stanislaw
    Huang, Vicky
    Zhao, Yingli
    Kyle, Alastair
    Minchinton, Andrew
    Karan, Tania
    Kohli, Kirpal
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 50 - 59
  • [43] Radiation Induced Acoustic Dosimetry of Electron Flash Radiotherapy
    Bjegovic, K.
    Sun, L.
    Pandey, P. K.
    Gonzalez, G.
    Vozenin, M. C.
    Limoli, C.
    Xiang, L.
    MEDICAL PHYSICS, 2024, 51 (10) : 7749 - 7749
  • [44] Alanine/electron spin resonance dosimetry for FLASH radiotherapy
    Gu, Runqiu
    Wang, Jianlin
    Wang, Pan
    Mao, Xin
    Lin, Binwei
    Tan, Wanchao
    Du, Xiaobo
    Gao, Feng
    Wang, Tingting
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [45] Characterization of plastic scintillator detector prototypes for the HERD experiment
    Serini, D.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2021, 44 (2-3):
  • [46] Along-away table with a plastic scintillator detector for in vivo dosimetry in HDR brachytherapy
    Tarrats-Rosell, J.
    Herreros, A.
    Neves, J.
    Melo, J.
    Moutinho, L.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1500 - S1502
  • [47] Plastic Scintillator Dosimetry of Ultrahigh Dose-Rate 200 MeV Electrons at CLEAR
    Hart, Alexander
    Giguere, Cloe
    Bateman, Joseph
    Korysko, Pierre
    Farabolini, Wilfrid
    Rieker, Vilde
    Esplen, Nolan
    Corsini, Roberto
    Dosanjh, Manjit
    Beaulieu, Luc
    Bazalova-Carter, Magdalena
    IEEE SENSORS JOURNAL, 2024, 24 (09) : 14229 - 14237
  • [48] Dose verification of radiotherapy for lung cancer by using plastic scintillator dosimetry and a heterogeneous phantom
    Ottosson, W.
    Behrens, C. F.
    Andersen, C. E.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [49] Proton Beam Dosimetry: a Comparison between a Plastic Scintillator, Ionization Chamber and Faraday Cup
    Ghergherehchi, Mitra
    Afarideh, Hossein
    Ghannadi, Mohammad
    Mohammadzadeh, Ahmad
    Aslani, Golam Reza
    Boghrati, Behzad
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 423 - 430
  • [50] CyberKnife multi-site small beam dosimetry with a new plastic scintillator detector
    Russo, S.
    Masi, L.
    Bergantin, A.
    De Martin, E.
    Doro, R.
    Frassanito, C.
    Fumagalli, M. L.
    Martinotti, A. S.
    Rondi, E.
    Vigorito, S.
    Mancosu, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S733 - S733