Characterization of a commercial plastic scintillator for electron FLASH dosimetry

被引:0
|
作者
Oh, Kyuhak [1 ]
Hyun, Megan A. [1 ]
Gallagher, Kyle J. [1 ]
Yan, Ying [1 ]
Zhou, Sumin [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE 68198 USA
来源
关键词
dosimetry; electron ultra-high dose rate (eFLASH); FLASH research extension (FLEX); plastic scintillator; BEAM DOSIMETRY; ION RECOMBINATION;
D O I
10.1002/acm2.14451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems.Methods and materialsWe assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film.ResultsWe observed that the 1 x 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 x 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of similar to 1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies.ConclusionsThis study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry
    Geso M.
    Robinson N.
    Schumer W.
    Williams K.
    Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (1): : 5 - 10
  • [32] Towards two-dimensional brachytherapy dosimetry using plastic scintillator: New highly efficient water equivalent plastic scintillator materials
    Kirov, AS
    Hurlbut, C
    Dempsey, JF
    Shrinivas, SB
    Epstein, JW
    Binns, WR
    Dowkontt, PF
    Williamson, JF
    MEDICAL PHYSICS, 1999, 26 (08) : 1515 - 1523
  • [33] Characterization of Plastic Scintillator Detectors for Radiation Therapy
    Liu, H.
    Lin, H.
    Darafsheh, A.
    Finlay, J.
    Both, S.
    Zhu, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 355 - 355
  • [34] Evaluation of a novel plastic scintillator dosimeter for in vivo dosimetry in an Elekta Unity Linac
    Ferrer, C.
    Huertas, C.
    Garcia, D.
    Saez, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1520 - S1521
  • [35] Nonproportionality of electron response using CCT: Plastic scintillator
    Limkitjaroenporrn, P.
    Kaewkhao, J.
    Limsuwan, P.
    Chewpraditkul, W.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (09) : 1780 - 1784
  • [36] DOSIMETRY WITH SCINTILLATOR SPECTACLES
    REISER, W
    KERNTECHNIK ISOTOPENTECHNIK UND CHEMIE, 1966, 8 (07): : 301 - &
  • [37] PL characterization of GaN scintillator for radioluminescence-based dosimetry
    Pittet, Patrick
    Lu, Guo-Neng
    Galvan, Jean-Marc
    Bluet, Jean-Marie
    Anas, Ismail
    Giraud, Jean-Yves
    Balosso, Jacques
    OPTICAL MATERIALS, 2009, 31 (10) : 1421 - 1424
  • [38] In-Vivo Dosimetry for Ultra-High Dose Rate (UHDR) Electron Beam FLASH Radiotherapy Using an Organic (Plastic), an Organic-Inorganic Hybrid and an Inorganic Point Scintillator System
    Vanreusel, Verdi
    Vallet, Hugo
    Wijnen, Jordi
    Cote, Benjamin
    Leblans, Paul
    Sterckx, Paul
    Vandenbroucke, Dirk
    Verellen, Dirk
    Nascimento, Luana de Freitas
    PHOTONICS, 2024, 11 (09)
  • [39] Investigation of the HyperscintTM plastic scintillation dosimetry system performance in a 15 MeV electron beam at FLASH dose rates
    Duzenli, Cheryl
    Mendez, Claudia
    Petric, Peter
    Karan, Tania
    MEDICAL PHYSICS, 2021, 48 (08) : 4666 - 4666
  • [40] Evaluation of commercial silicon diode for electron dosimetry
    Khoury, H. J.
    Schelin, H.
    Soboll, D.
    Lunelli, N.
    Baptista, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 537 - 539