A novel aptasensor platform for the detection of carcinoembryonic antigen using quartz crystal microbalance

被引:1
|
作者
Erkal-Aytemur, Asli [1 ]
Mulazimog, Ibrahim Ender [2 ]
Ustundag, Zafer [3 ]
Caglayan, Mustafa Oguzhan [4 ]
机构
[1] Alanya Alaaddin Keykubat Univ, RK Fac Engn, Fundamental Sci, Antalya, Turkiye
[2] Necmettin Erbakan Univ, AK Educ Fac, Chem Dept, Konya, Turkiye
[3] Kutahya Dumlupinar Univ, Fac Arts & Sci, Dept Chem, Kutahya, Turkiye
[4] Bilecik Seyh Edebali Univ, Fac Engn, Dept BioEngn, Bilecik, Turkiye
关键词
Carcinoembryonic antigen; Electrochemical modification; Quartz crystal microbalance; Aptasensor; GLASSY-CARBON ELECTRODE; FLUORESCENCE DETECTION; BREAST-CANCER; GOLD; NANOPARTICLES; BIOSENSOR; CEA; AU; SURFACE; AMPLIFICATION;
D O I
10.1016/j.talanta.2024.126376
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a quartz crystal microbalance (QCM) aptasensor for carcinoembryonic antigen (CEA), a well-known biomarker for various cancer types, was reported, utilizing two different aptamers. To achieve this, a nanofilm of 4-mercaptophenyl was electrochemically attached to gold-coated QCM crystal surfaces via the reduction of 4mercaptobenzenediazonium salt (4 MB-DAT) using cyclic voltammetry. Subsequently, gold nanoparticles (AuNP) were affixed to this structure, and then aptamers (antiCEA1 and antiCEA2) modified with SH-functional ends bound to AuNPs completed the modification. The analytical performance of the CEA sensor was evaluated through simultaneous QCM measurements employing CEA solutions ranging from 0.1 ng/mL to 25 ng/mL. The detection limit (LOD) for CEA was determined to be 102 pg/mL for antiCEA1 and 108 pg/mL for antiCEA2 aptamers. Interday and intraday precision and accuracy tests yielded maximum results of 4.3 and + 3.8, respectively, for both aptasensors, as measured by relative standard deviation (RSD%) and relative error (RE%). The kinetic data of the aptasensors resulted in affinity values (KD) of 0.43 +/- 0.14 nM for antiCEA1 and 0.75 +/- 0.42 nM for antiCEA2. These values were lower than the reported values of 3.9 nM and 37.8 nM for both aptamers, respectively. The selectivity of the aptasensor was evaluated by measuring the signal changes caused by alpha-fetoprotein (AFP), cancer antigen (CA-125), and vascular endothelial growth factor (VEGF-165) individually and together at a concentration of 500 ng/mL, resulting in a maximum 4.1 % change, which was comparable to precision and accuracy values reported in the literature. After confirming the selectivity of the aptamers, recovery experiments were conducted using spiked commercial serum samples to simulate real samples, and the lowest recovery value obtained was 95.4 %. It was determined that two different aptasensors could be successfully used for the QCM-based detection of CEA in this study.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Ochratoxin A Detection by an Immunosensor Using Impedance Spectroscopy Coupled with Quartz Crystal Microbalance
    Cheap, H.
    Sanchez, M.
    Vivier, V.
    Perrot, H.
    Marty, J. L.
    SENSOR LETTERS, 2011, 9 (06) : 2312 - 2315
  • [42] Immobilization, Hybridization and Amperometric Detection of DNA Sensor Using Quartz Crystal Microbalance
    Lee, Dong-Yun
    Choi, Won-Suk
    Kafi, A. K. M.
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (09) : 4553 - 4556
  • [43] Polymer-Plasticizer Coatings for BTEX Detection Using Quartz Crystal Microbalance
    Iyer, Abhijeet
    Mitevska, Veselinka
    Samuelson, Jonathan
    Campbell, Scott
    Bhethanabotla, Venkat R.
    SENSORS, 2021, 21 (16)
  • [44] Detection of biofilm activities using chip calorimetry and quartz crystal microbalance technology
    Wolf, A.
    Lerchner, J.
    Huettl, R.
    Seidel, J.
    Mertens, F.
    Buchholz, F.
    Maskow, T.
    Neu, T.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 298 : 33 - 33
  • [45] CHARACTERISTICS OF A SIMPLE DETECTION LOGGING SYSTEM FOR MERCURY USING QUARTZ CRYSTAL MICROBALANCE
    Noda, Kazutoshi
    Aizawa, Hidenobu
    Marumoto, Kohji
    2019 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2019), 2019, : 278 - 280
  • [46] Rapid detection of bacterial spores using a quartz crystal microbalance (QCM) immunoassay
    Lee, SH
    Stubbs, DD
    Cairney, J
    Hunt, WD
    IEEE SENSORS JOURNAL, 2005, 5 (04) : 737 - 743
  • [47] The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance
    Hewa, Thamara M. Peduru
    Tannock, Gregory A.
    Mainwaring, David E.
    Harrison, Sally
    Fecondo, John V.
    JOURNAL OF VIROLOGICAL METHODS, 2009, 162 (1-2) : 14 - 21
  • [48] DETECTION OF INTERCALATION BEHAVIORS OF DYES IN DNAS USING A QUARTZ-CRYSTAL MICROBALANCE
    OKAHATA, Y
    MATSUZAKI, Y
    IJIRO, K
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 380 - 383
  • [49] DETECTION OF CELL-ADHESION BEHAVIORS BY USING A QUARTZ-CRYSTAL MICROBALANCE
    EBATO, H
    OKAHATA, Y
    MATSUDA, T
    KOBUNSHI RONBUNSHU, 1993, 50 (06) : 463 - 469
  • [50] Dimethyl Methylphosphonate Detection Using a Quartz Crystal Microbalance as Chemical Warfare Sensor
    Lee, Young-Jun
    Kim, Gwang-Hoon
    Jung, Dongsoo
    Kim, Joo-Hyung
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2015, 7 (12) : 1015 - 1018