A novel aptasensor platform for the detection of carcinoembryonic antigen using quartz crystal microbalance

被引:1
|
作者
Erkal-Aytemur, Asli [1 ]
Mulazimog, Ibrahim Ender [2 ]
Ustundag, Zafer [3 ]
Caglayan, Mustafa Oguzhan [4 ]
机构
[1] Alanya Alaaddin Keykubat Univ, RK Fac Engn, Fundamental Sci, Antalya, Turkiye
[2] Necmettin Erbakan Univ, AK Educ Fac, Chem Dept, Konya, Turkiye
[3] Kutahya Dumlupinar Univ, Fac Arts & Sci, Dept Chem, Kutahya, Turkiye
[4] Bilecik Seyh Edebali Univ, Fac Engn, Dept BioEngn, Bilecik, Turkiye
关键词
Carcinoembryonic antigen; Electrochemical modification; Quartz crystal microbalance; Aptasensor; GLASSY-CARBON ELECTRODE; FLUORESCENCE DETECTION; BREAST-CANCER; GOLD; NANOPARTICLES; BIOSENSOR; CEA; AU; SURFACE; AMPLIFICATION;
D O I
10.1016/j.talanta.2024.126376
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a quartz crystal microbalance (QCM) aptasensor for carcinoembryonic antigen (CEA), a well-known biomarker for various cancer types, was reported, utilizing two different aptamers. To achieve this, a nanofilm of 4-mercaptophenyl was electrochemically attached to gold-coated QCM crystal surfaces via the reduction of 4mercaptobenzenediazonium salt (4 MB-DAT) using cyclic voltammetry. Subsequently, gold nanoparticles (AuNP) were affixed to this structure, and then aptamers (antiCEA1 and antiCEA2) modified with SH-functional ends bound to AuNPs completed the modification. The analytical performance of the CEA sensor was evaluated through simultaneous QCM measurements employing CEA solutions ranging from 0.1 ng/mL to 25 ng/mL. The detection limit (LOD) for CEA was determined to be 102 pg/mL for antiCEA1 and 108 pg/mL for antiCEA2 aptamers. Interday and intraday precision and accuracy tests yielded maximum results of 4.3 and + 3.8, respectively, for both aptasensors, as measured by relative standard deviation (RSD%) and relative error (RE%). The kinetic data of the aptasensors resulted in affinity values (KD) of 0.43 +/- 0.14 nM for antiCEA1 and 0.75 +/- 0.42 nM for antiCEA2. These values were lower than the reported values of 3.9 nM and 37.8 nM for both aptamers, respectively. The selectivity of the aptasensor was evaluated by measuring the signal changes caused by alpha-fetoprotein (AFP), cancer antigen (CA-125), and vascular endothelial growth factor (VEGF-165) individually and together at a concentration of 500 ng/mL, resulting in a maximum 4.1 % change, which was comparable to precision and accuracy values reported in the literature. After confirming the selectivity of the aptamers, recovery experiments were conducted using spiked commercial serum samples to simulate real samples, and the lowest recovery value obtained was 95.4 %. It was determined that two different aptasensors could be successfully used for the QCM-based detection of CEA in this study.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] DETECTION OF CO2 USING A QUARTZ-CRYSTAL MICROBALANCE
    GOMES, MT
    DUARTE, AC
    OLIVEIRA, JP
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) : 191 - 194
  • [22] Detection of linalool in black tea using a quartz crystal microbalance sensor
    Sharma, Prolay
    Ghosh, Arunangshu
    Tudu, Bipan
    Bhuyan, Lakshi Prasad
    Tamuly, Pradip
    Bhattacharyya, Nabarun
    Bandyopadhyay, Rajib
    Chatterjee, Anutosh
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 318 - 325
  • [23] Detection of Liquid Penetration of a Micropillar Surface Using the Quartz Crystal Microbalance
    Wang, Pengtao
    Su, Junwei
    Shen, Mengyan
    Ruths, Marina
    Sun, Hongwei
    LANGMUIR, 2017, 33 (02) : 638 - 644
  • [24] Detection of Cadmium Ion in Potable Water Using Quartz Crystal Microbalance
    Taneja, Parul
    Manjuladevi, V.
    Gupta, Rajiv
    Gupta, Rajiv K.
    MACROMOLECULAR SYMPOSIA, 2017, 376 (01)
  • [25] Quartz Crystal Microbalance Sensor Using Ionophore for Ammonium Ion Detection
    Kosaki, Yasuhiro
    Takano, Kosuke
    Citterio, Daniel
    Suzuki, Koji
    Shiratori, Seimei
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (01) : 563 - 567
  • [26] Detection of Cartilage Oligomeric Matrix Protein Using a Quartz Crystal Microbalance
    Wang, Shih-Han
    Shen, Chi-Yen
    Weng, Ting-Chan
    Lin, Pin-Hsuan
    Yang, Jia-Jyun
    Chen, I-Fen
    Kuo, Shyh-Ming
    Chang, Shwu-Jen
    Tu, Yuan-Kun
    Kao, Yu-Hsien
    Hung, Chih-Hsin
    SENSORS, 2010, 10 (12): : 11633 - 11643
  • [27] Detection of surfactants in rinse water using a quartz crystal microbalance technique
    Lee, KT
    Raghavan, S
    Mathew, V
    PROCEEDINGS OF THE SYMPOSIUM ON ENVIRONMENTAL ASPECTS OF ELECTROCHEMICAL TECHNOLOGY: APPLICATIONS IN ELECTRONICS, 1997, 96 (21): : 126 - 139
  • [28] A Novel Electrochemical Aptasensor for Carcinoembryonic Antigen Detection Based on Target-induced Bridge Assembly
    Taghdisi, Seyed Mohammad
    Danesh, Noor Mohammad
    Ramezani, Mohammad
    Emrani, Ahmad Sarreshtehdar
    Abnous, Khalil
    ELECTROANALYSIS, 2018, 30 (08) : 1726 - 1731
  • [29] A novel aptasensor based on HCR and G-quadruplex DNAzyme for fluorescence detection of Carcinoembryonic Antigen
    Bai, Yunfeng
    Zhang, Huilin
    Zhao, Lu
    Wang, Yuzhen
    Chen, Xiaoliang
    Zhai, Hong
    Tian, Maozhong
    Zhao, Ruirui
    Wang, Tao
    Xu, Hui
    Feng, Feng
    TALANTA, 2021, 221
  • [30] Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method
    Yao, Jia
    Feng, Bin
    Zhang, Zhiqi
    Li, Chuanyu
    Zhang, Wei
    Guo, Zhen
    Zhao, Heming
    Zhou, Lianqun
    SENSORS, 2018, 18 (09)