A novel aptasensor platform for the detection of carcinoembryonic antigen using quartz crystal microbalance

被引:1
|
作者
Erkal-Aytemur, Asli [1 ]
Mulazimog, Ibrahim Ender [2 ]
Ustundag, Zafer [3 ]
Caglayan, Mustafa Oguzhan [4 ]
机构
[1] Alanya Alaaddin Keykubat Univ, RK Fac Engn, Fundamental Sci, Antalya, Turkiye
[2] Necmettin Erbakan Univ, AK Educ Fac, Chem Dept, Konya, Turkiye
[3] Kutahya Dumlupinar Univ, Fac Arts & Sci, Dept Chem, Kutahya, Turkiye
[4] Bilecik Seyh Edebali Univ, Fac Engn, Dept BioEngn, Bilecik, Turkiye
关键词
Carcinoembryonic antigen; Electrochemical modification; Quartz crystal microbalance; Aptasensor; GLASSY-CARBON ELECTRODE; FLUORESCENCE DETECTION; BREAST-CANCER; GOLD; NANOPARTICLES; BIOSENSOR; CEA; AU; SURFACE; AMPLIFICATION;
D O I
10.1016/j.talanta.2024.126376
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a quartz crystal microbalance (QCM) aptasensor for carcinoembryonic antigen (CEA), a well-known biomarker for various cancer types, was reported, utilizing two different aptamers. To achieve this, a nanofilm of 4-mercaptophenyl was electrochemically attached to gold-coated QCM crystal surfaces via the reduction of 4mercaptobenzenediazonium salt (4 MB-DAT) using cyclic voltammetry. Subsequently, gold nanoparticles (AuNP) were affixed to this structure, and then aptamers (antiCEA1 and antiCEA2) modified with SH-functional ends bound to AuNPs completed the modification. The analytical performance of the CEA sensor was evaluated through simultaneous QCM measurements employing CEA solutions ranging from 0.1 ng/mL to 25 ng/mL. The detection limit (LOD) for CEA was determined to be 102 pg/mL for antiCEA1 and 108 pg/mL for antiCEA2 aptamers. Interday and intraday precision and accuracy tests yielded maximum results of 4.3 and + 3.8, respectively, for both aptasensors, as measured by relative standard deviation (RSD%) and relative error (RE%). The kinetic data of the aptasensors resulted in affinity values (KD) of 0.43 +/- 0.14 nM for antiCEA1 and 0.75 +/- 0.42 nM for antiCEA2. These values were lower than the reported values of 3.9 nM and 37.8 nM for both aptamers, respectively. The selectivity of the aptasensor was evaluated by measuring the signal changes caused by alpha-fetoprotein (AFP), cancer antigen (CA-125), and vascular endothelial growth factor (VEGF-165) individually and together at a concentration of 500 ng/mL, resulting in a maximum 4.1 % change, which was comparable to precision and accuracy values reported in the literature. After confirming the selectivity of the aptamers, recovery experiments were conducted using spiked commercial serum samples to simulate real samples, and the lowest recovery value obtained was 95.4 %. It was determined that two different aptasensors could be successfully used for the QCM-based detection of CEA in this study.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Optimisation of an electrochemical impedance spectroscopy aptasensor by exploiting quartz crystal microbalance with dissipation signals
    Formisano, Nello
    Jolly, Pawan
    Bhalla, Nikhil
    Cromhout, Mary
    Flanagan, Shane P.
    Fogel, Ronen
    Limson, Janice L.
    Estrela, Pedro
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 369 - 375
  • [32] Aptasensor for lead(II) based on the use of a quartz crystal microbalance modified with gold nanoparticles
    Yuan, Min
    Song, Zhihong
    Fei, Jiayu
    Wang, Xinglong
    Xu, Fei
    Cao, Hui
    Yu, Jinsong
    MICROCHIMICA ACTA, 2017, 184 (05) : 1397 - 1403
  • [33] The quantification of potassium using a quartz crystal microbalance
    Teresa, M
    Gomes, SR
    Tavares, KS
    Oliveira, JABP
    ANALYST, 2000, 125 (11) : 1983 - 1986
  • [34] Aptasensor for lead(II) based on the use of a quartz crystal microbalance modified with gold nanoparticles
    Min Yuan
    Zhihong Song
    Jiayu Fei
    Xinglong Wang
    Fei Xu
    Hui Cao
    Jinsong Yu
    Microchimica Acta, 2017, 184 : 1397 - 1403
  • [35] Human cytomegalovirus detection by a quartz crystal microbalance immunosensor
    Susmel, S
    O'Sullivan, CK
    Guilbault, GG
    ENZYME AND MICROBIAL TECHNOLOGY, 2000, 27 (09) : 639 - 645
  • [36] Graphene oxide-Au nano particle coated quartz crystal microbalance biosensor for the real time analysis of carcinoembryonic antigen
    Jandas, P. J.
    Luo, Jingting
    Quan, Aojie
    Li, Chong
    Fu, Chen
    Fu, Y. Q.
    RSC ADVANCES, 2020, 10 (07) : 4118 - 4128
  • [37] A quartz crystal microbalance biosensor for the detection of total IgE
    Fahrullin, R.
    Fassakhov, R.
    Sukmanskaya, E.
    Konovalova, O.
    ALLERGY, 2007, 62 : 146 - 146
  • [38] QUARTZ CRYSTAL MICROBALANCE USED AS SENSOR FOR PESTICIDES DETECTION
    Dulama, Ioana Daniela
    Radulescu, Cristiana
    Bucurica, Ioan Alin
    Teodorescu, Sofia
    Stirbescu, Raluca Maria
    Cimpoca, Gheorghe Valerica
    Let, Dorin Dacian
    Gurgu, Ion Valentin
    JOURNAL OF SCIENCE AND ARTS, 2018, (02): : 445 - 452
  • [39] Aptasensor based on tripetalous cadmium sulfidegraphene electrochemiluminescence for the detection of carcinoembryonic antigen
    Shi, Gui-Fang
    Cao, Jun-Tao
    Zhang, Jing-Jing
    Huang, Ke-Jing
    Liu, Yan-Ming
    Chen, Yong-Hong
    Ren, Shu-Wei
    ANALYST, 2014, 139 (22) : 5827 - 5834
  • [40] Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors
    Eun, AJC
    Huang, LQ
    Chew, FT
    Li, SFY
    Wong, SM
    JOURNAL OF VIROLOGICAL METHODS, 2002, 99 (1-2) : 71 - 79