Proton CT on biological phantoms for x-ray CT calibration in proton treatment planning

被引:2
|
作者
Fogazzi, Elena [1 ,2 ]
Bruzzi, Mara [3 ,4 ]
D'Amato, Elvira [1 ]
Farace, Paolo [2 ,5 ]
Righetto, Roberto [2 ,5 ]
Scaringella, Monica [4 ]
Scarpa, Marina [1 ,2 ]
Tommasino, Francesco [1 ,2 ]
Civinini, Carlo [4 ]
机构
[1] Univ Trento, Phys Dept, Via Sommar 14, Povo, TN, Italy
[2] Italian Natl Inst Nucl Phys INFN, Trento Inst Fundamental Phys & Applicat TIFPA, Via Sommar 14, Povo, TN, Italy
[3] Univ Florence, Phys & Astron Dept, Via G Sansone 1, Sesto Fiorentino, FI, Italy
[4] Italian Natl Inst Nucl Phys INFN, Florence Sect, Via G Sansone 1, Sesto Fiorentino, FI, Italy
[5] Hosp Trento, Med Phys Unit, Azienda Prov & Serv Sanitari APSS, Via Paolo Orsi 1, Trento, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 13期
关键词
proton therapy; ion imaging; CT calibration; ENERGY COMPUTED-TOMOGRAPHY; STOPPING-POWER PREDICTION; RANGE UNCERTAINTIES; STOICHIOMETRIC CALIBRATION; EXPERIMENTAL-VERIFICATION; THERAPY; NUMBER; TISSUE; RATIO; HU;
D O I
10.1088/1361-6560/ad56f5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To present and characterize a novel method for x-ray computed tomography (xCT) calibration in proton treatment planning, based on proton CT (pCT) measurements on biological phantoms. Approach. A pCT apparatus was used to perform direct measurements of 3D stopping power relative to water (SPR) maps on stabilized, biological phantoms. Two single-energy xCT calibration curves-i.e. tissue substitutes and stoichiometric-were compared to pCT data. Moreover, a new calibration method based on these data was proposed, and verified against intra- and inter-species variability, dependence on stabilization, beam-hardening conditions, and analysis procedures. Main results. Biological phantoms were verified to be stable in time, with a dependence on temperature conditions, especially in the fat region: (-2.5 (sic) 0.5) HU degrees C-1. The pCT measurements were compared with standard xCT calibrations, revealing an average SPR discrepancy within +/- 1.60% for both fat and muscle regions. In the bone region the xCT calibrations overestimated the pCT-measured SPR of the phantom, with a maximum discrepancy of about +3%. As a result, a new cross-calibration curve was directly extracted from the pCT data. Overall, the SPR uncertainty margin associated with this curve was below 3%; fluctuations in the uncertainty values were observed across the HU range. Cross-calibration curves obtained with phantoms made of different animal species and anatomical parts were reproducible with SPR discrepancies within 3%. Moreover, the stabilization procedure did not affect the resulting curve within a 2.2% SPR deviation. Finally, the cross-calibration curve was affected by the beam-hardening conditions on xCTs, especially in the bone region, while dependencies below 2% resulted from the image registration procedure. Significance. Our results showed that pCT measurements on biological phantoms may provide an accurate method for the verification of current xCT calibrations and may represent a tool for the implementation of a new calibration method for proton treatment planning.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Technical Note: CT calibration for proton treatment planning by cross-calibration with proton CT data
    Farace, Paolo
    Tommasino, Francesco
    Righetto, Roberto
    Fracchiolla, Francesco
    Scaringella, Monica
    Bruzzi, Mara
    Civinini, Carlo
    MEDICAL PHYSICS, 2021, 48 (03) : 1349 - 1355
  • [2] Characterization of the INFN proton CT scanner for cross-calibration of x-ray CT
    Fogazzi, Elena
    Trevisan, Diego
    Farace, Paolo
    Righetto, Roberto
    Rit, Simon
    Scaringella, Monica
    Bruzzi, Mara
    Tommasino, Francesco
    Civinini, Carlo
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (12):
  • [3] Proton Beam X-Ray Fluorescence CT
    Bazalova, M.
    Ahmad, M.
    Fahrig, R.
    Xing, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 449 - 449
  • [4] Comparison of x-ray CT and proton based CT planning in the presence of titanium dental implants
    Oancea, C.
    Shipulin, K.
    Mytsin, G.
    Gao, M.
    Pankuch, M.
    Coutrakon, G.
    Ordonez, C.
    Johnson, R. P.
    Bashkirov, V.
    Schulte, R.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S470 - S471
  • [5] Comparison of Proton Stopping Power Measurements of Animal Tissues From Proton CT and X-Ray CT Systems
    DeJongh, D.
    DeJongh, E.
    Rykalin, V.
    Pankuch, M.
    Kreydick, B.
    Welsh, J.
    Schulte, R.
    Karonis, N.
    Ordonez, C.
    Duffin, K.
    Winans, J.
    Coutrakon, G.
    Sarosiek, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E592 - E592
  • [6] A comparison of proton stopping power measured with proton CT and x-ray CT in fresh postmortem porcine structures
    DeJongh, Don F.
    DeJongh, Ethan A.
    Rykalin, Victor
    DeFillippo, Greg
    Pankuch, Mark
    Best, Andrew W.
    Coutrakon, George
    Duffin, Kirk L.
    Karonis, Nicholas T.
    Ordonez, Caesar E.
    Sarosiek, Christina
    Schulte, Reinhard W.
    Winans, John R.
    Block, Alec M.
    Hentz, Courtney L.
    Welsh, James S.
    MEDICAL PHYSICS, 2021, 48 (12) : 7998 - 8009
  • [7] Proton computed tomography as a tool for proton therapy planning: preliminary computer simulations and comparisons with x-ray CT basics
    de Assis, JT
    Yevseyeva, O
    Evseev, I
    Lopes, RT
    Schelin, HR
    Klock, WCL
    Paschuk, SA
    Schulte, RW
    Williams, DC
    X-RAY SPECTROMETRY, 2005, 34 (06) : 481 - 492
  • [8] Proton radiography to calibrate relative proton stopping power from X-ray CT in proton radiotherapy
    Biegun, A. K.
    Marin, K. Ortega
    Brandenburg, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S817 - S818
  • [9] Stopping power measurement for proton therapy by combining proton radiography and X-ray CT
    Kataura, R.
    Izumikawa, T.
    Konno, T.
    Kawasaki, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [10] Proton-induced x-ray fluorescence CT imaging
    Bazalova-Carter, Magdalena
    Ahmad, Moiz
    Matsuura, Taeko
    Takao, Seishin
    Matsuo, Yuto
    Fahrig, Rebecca
    Shirato, Hiroki
    Umegaki, Kikuo
    Xing, Lei
    MEDICAL PHYSICS, 2015, 42 (02) : 900 - 907