Proton CT on biological phantoms for x-ray CT calibration in proton treatment planning

被引:2
|
作者
Fogazzi, Elena [1 ,2 ]
Bruzzi, Mara [3 ,4 ]
D'Amato, Elvira [1 ]
Farace, Paolo [2 ,5 ]
Righetto, Roberto [2 ,5 ]
Scaringella, Monica [4 ]
Scarpa, Marina [1 ,2 ]
Tommasino, Francesco [1 ,2 ]
Civinini, Carlo [4 ]
机构
[1] Univ Trento, Phys Dept, Via Sommar 14, Povo, TN, Italy
[2] Italian Natl Inst Nucl Phys INFN, Trento Inst Fundamental Phys & Applicat TIFPA, Via Sommar 14, Povo, TN, Italy
[3] Univ Florence, Phys & Astron Dept, Via G Sansone 1, Sesto Fiorentino, FI, Italy
[4] Italian Natl Inst Nucl Phys INFN, Florence Sect, Via G Sansone 1, Sesto Fiorentino, FI, Italy
[5] Hosp Trento, Med Phys Unit, Azienda Prov & Serv Sanitari APSS, Via Paolo Orsi 1, Trento, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 13期
关键词
proton therapy; ion imaging; CT calibration; ENERGY COMPUTED-TOMOGRAPHY; STOPPING-POWER PREDICTION; RANGE UNCERTAINTIES; STOICHIOMETRIC CALIBRATION; EXPERIMENTAL-VERIFICATION; THERAPY; NUMBER; TISSUE; RATIO; HU;
D O I
10.1088/1361-6560/ad56f5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To present and characterize a novel method for x-ray computed tomography (xCT) calibration in proton treatment planning, based on proton CT (pCT) measurements on biological phantoms. Approach. A pCT apparatus was used to perform direct measurements of 3D stopping power relative to water (SPR) maps on stabilized, biological phantoms. Two single-energy xCT calibration curves-i.e. tissue substitutes and stoichiometric-were compared to pCT data. Moreover, a new calibration method based on these data was proposed, and verified against intra- and inter-species variability, dependence on stabilization, beam-hardening conditions, and analysis procedures. Main results. Biological phantoms were verified to be stable in time, with a dependence on temperature conditions, especially in the fat region: (-2.5 (sic) 0.5) HU degrees C-1. The pCT measurements were compared with standard xCT calibrations, revealing an average SPR discrepancy within +/- 1.60% for both fat and muscle regions. In the bone region the xCT calibrations overestimated the pCT-measured SPR of the phantom, with a maximum discrepancy of about +3%. As a result, a new cross-calibration curve was directly extracted from the pCT data. Overall, the SPR uncertainty margin associated with this curve was below 3%; fluctuations in the uncertainty values were observed across the HU range. Cross-calibration curves obtained with phantoms made of different animal species and anatomical parts were reproducible with SPR discrepancies within 3%. Moreover, the stabilization procedure did not affect the resulting curve within a 2.2% SPR deviation. Finally, the cross-calibration curve was affected by the beam-hardening conditions on xCTs, especially in the bone region, while dependencies below 2% resulted from the image registration procedure. Significance. Our results showed that pCT measurements on biological phantoms may provide an accurate method for the verification of current xCT calibrations and may represent a tool for the implementation of a new calibration method for proton treatment planning.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] CT Calibration for Proton Therapy Planning of Pediatric Patients
    Baer, E.
    Collins-Fekete, C. A.
    Rompokos, V.
    Warry, A.
    Poynter, A.
    Royle, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E258 - E259
  • [12] CT calibration for precise proton therapy planning in children
    Baer, E.
    Collins-Fekete, C.
    Rompokos, V.
    Zhang, Y.
    Gaze, M.
    Warry, A.
    Poynter, A.
    Royle, G.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S404 - S406
  • [13] Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy
    Dedes, George
    Dickmann, Jannis
    Niepel, Katharina
    Wesp, Philipp
    Johnson, Robert P.
    Pankuch, Mark
    Bashkirov, Vladimir
    Rits, Simon
    Volz, Lennart
    Schulte, Reinhard W.
    Landry, Guillaume
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):
  • [14] Monte Carlo evaluation of X-ray and proton CT for the prediction of the range of proton therapy beams
    Arbor, N.
    Dauvergne, D.
    Dedes, G.
    Letang, J. M.
    Parodi, K.
    Quinones, C. T.
    Testa, E.
    Rit, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S66 - S66
  • [15] Monte Carlo comparison of x-ray and proton CT for range calculations of proton therapy beams
    Arbor, N.
    Dauvergne, D.
    Dedes, G.
    Letang, J. M.
    Parodi, K.
    Quinones, C. T.
    Testa, E.
    Rit, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19): : 7585 - 7599
  • [16] Static superconducting gantry-based proton CT combined with X-ray CT as prior image for FLASH proton therapy
    Yu-Qing Yang
    Wen-Cheng Fang
    Xiao-Xia Huang
    Jian-Hao Tan
    Cheng Wang
    Chao-Peng Wang
    Zhen-Tang Zhao
    Nuclear Science and Techniques, 2023, 34
  • [17] Static superconducting gantry-based proton CT combined with X-ray CT as prior image for FLASH proton therapy
    Yu-Qing Yang
    Wen-Cheng Fang
    Xiao-Xia Huang
    Jian-Hao Tan
    Cheng Wang
    Chao-Peng Wang
    Zhen-Tang Zhao
    Nuclear Science and Techniques, 2023, 34 (01) : 127 - 137
  • [18] Static superconducting gantry-based proton CT combined with X-ray CT as prior image for FLASH proton therapy
    Yang, Yu-Qing
    Fang, Wen-Cheng
    Huang, Xiao-Xia
    Tan, Jian-Hao
    Wang, Cheng
    Wang, Chao-Peng
    Zhao, Zhen-Tang
    NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (01)
  • [19] Registration of pencil beam proton radiography data with X-ray CT
    Deffet, Sylvain
    Macq, Benoit
    Righetto, Roberto
    Stappen, Francois Vander
    Farace, Paolo
    MEDICAL PHYSICS, 2017, 44 (10) : 5393 - 5401
  • [20] X-Ray Fluorescence CT Induced by Proton Beam: Experiments and Simulations
    Bazalova-Carter, M.
    Ahmad, M.
    Matsuura, T.
    Takao, S.
    Matsuo, Y.
    Fahrig, R.
    Shirato, H.
    Umegaki, K.
    Xing, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3716 - 3716