Proton CT on biological phantoms for x-ray CT calibration in proton treatment planning

被引:2
|
作者
Fogazzi, Elena [1 ,2 ]
Bruzzi, Mara [3 ,4 ]
D'Amato, Elvira [1 ]
Farace, Paolo [2 ,5 ]
Righetto, Roberto [2 ,5 ]
Scaringella, Monica [4 ]
Scarpa, Marina [1 ,2 ]
Tommasino, Francesco [1 ,2 ]
Civinini, Carlo [4 ]
机构
[1] Univ Trento, Phys Dept, Via Sommar 14, Povo, TN, Italy
[2] Italian Natl Inst Nucl Phys INFN, Trento Inst Fundamental Phys & Applicat TIFPA, Via Sommar 14, Povo, TN, Italy
[3] Univ Florence, Phys & Astron Dept, Via G Sansone 1, Sesto Fiorentino, FI, Italy
[4] Italian Natl Inst Nucl Phys INFN, Florence Sect, Via G Sansone 1, Sesto Fiorentino, FI, Italy
[5] Hosp Trento, Med Phys Unit, Azienda Prov & Serv Sanitari APSS, Via Paolo Orsi 1, Trento, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 13期
关键词
proton therapy; ion imaging; CT calibration; ENERGY COMPUTED-TOMOGRAPHY; STOPPING-POWER PREDICTION; RANGE UNCERTAINTIES; STOICHIOMETRIC CALIBRATION; EXPERIMENTAL-VERIFICATION; THERAPY; NUMBER; TISSUE; RATIO; HU;
D O I
10.1088/1361-6560/ad56f5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To present and characterize a novel method for x-ray computed tomography (xCT) calibration in proton treatment planning, based on proton CT (pCT) measurements on biological phantoms. Approach. A pCT apparatus was used to perform direct measurements of 3D stopping power relative to water (SPR) maps on stabilized, biological phantoms. Two single-energy xCT calibration curves-i.e. tissue substitutes and stoichiometric-were compared to pCT data. Moreover, a new calibration method based on these data was proposed, and verified against intra- and inter-species variability, dependence on stabilization, beam-hardening conditions, and analysis procedures. Main results. Biological phantoms were verified to be stable in time, with a dependence on temperature conditions, especially in the fat region: (-2.5 (sic) 0.5) HU degrees C-1. The pCT measurements were compared with standard xCT calibrations, revealing an average SPR discrepancy within +/- 1.60% for both fat and muscle regions. In the bone region the xCT calibrations overestimated the pCT-measured SPR of the phantom, with a maximum discrepancy of about +3%. As a result, a new cross-calibration curve was directly extracted from the pCT data. Overall, the SPR uncertainty margin associated with this curve was below 3%; fluctuations in the uncertainty values were observed across the HU range. Cross-calibration curves obtained with phantoms made of different animal species and anatomical parts were reproducible with SPR discrepancies within 3%. Moreover, the stabilization procedure did not affect the resulting curve within a 2.2% SPR deviation. Finally, the cross-calibration curve was affected by the beam-hardening conditions on xCTs, especially in the bone region, while dependencies below 2% resulted from the image registration procedure. Significance. Our results showed that pCT measurements on biological phantoms may provide an accurate method for the verification of current xCT calibrations and may represent a tool for the implementation of a new calibration method for proton treatment planning.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Validation of the Implementation of Different CT Scanners in Proton Treatment Planning
    Fuentes, C. Llina
    Geismer, D.
    Christiaens, M.
    Vermeren, X.
    Ding, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3226 - 3226
  • [32] Impact of CT Metal Artifacts on Proton Radiotherapy Treatment Planning
    Verburg, J. M.
    Joshi, M. C.
    Madden, T. M.
    Kooy, H. M.
    Seco, J. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S809 - S810
  • [33] Assessment of the impact of CT calibration procedures for proton therapy planning on pediatric treatments
    Bar, Esther
    Collins-Fekete, Charles-Antoine
    Rompokos, Vasilis
    Zhang, Ying
    Gaze, Mark N.
    Warry, Alison
    Poynter, Andrew
    Royle, Gary
    MEDICAL PHYSICS, 2021, 48 (09) : 5202 - 5218
  • [34] Experimental comparison of relative stopping power evaluation between proton CT and x-ray CT for pre-clinical proton irradiation studies of small animals
    Terakawa, Atsuki
    Hosokawa, Hibiki
    Nogami, Mitsuhiro
    Hitomi, Keitaro
    Ishii, Keizo
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (09):
  • [35] Patient Specific Proton Stopping Powers Estimation by Combining Proton Radiography and Prior-Knowledge X-Ray CT Information
    Collins-Fekete, C. A.
    Brousmiche, S.
    Hansen, D.
    Beaulieu, L.
    Seco, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3199 - 3200
  • [36] MCNPX simulation of proton dose distribution in homogeneous and CT phantoms
    Lee, C. C.
    Lee, Y. J.
    Tung, C. J.
    Cheng, H. W.
    Chao, T. C.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 302 - 304
  • [37] Deformable image registration of the treatment planning CT with proton radiographies in perspective of adaptive proton therapy
    Palaniappan, Prasannakumar
    Meyer, Sebastian
    Kamp, Florian
    Belka, Claus
    Riboldi, Marco
    Parodi, Katia
    Gianoli, Chiara
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04):
  • [38] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [39] A direct comparison of multi-energy x-ray and proton CT for imaging and relative stopping power estimation of plastic and ex-vivo phantoms
    Fogazzi, Elena
    Hu, Guyue
    Bruzzi, Mara
    Farace, Paolo
    Kroencke, Thomas
    Niepel, Katharina
    Ricke, Jens
    Risch, Franka
    Sabel, Bastian
    Scaringella, Monica
    Schwarz, Florian
    Tommasino, Francesco
    Landry, Guillaume
    Civinini, Carlo
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (17):
  • [40] A new imaging mode based on X-ray CT as prior image and sparsely sampled projections for rapid clinical proton CT
    Yu-Qing Yang
    Wen-Cheng Fang
    Xiao-Xia Huang
    Qiang Du
    Ming Li
    Jian Zheng
    Zhen-Tang Zhao
    Nuclear Science and Techniques, 2023, 34