CCD SOFT-X-RAY IMAGING SPECTROMETER FOR THE ASCA SATELLITE

被引:141
|
作者
BURKE, BE
MOUNTAIN, RW
DANIELS, PJ
COOPER, MJ
DOLAT, VS
机构
[1] The Lincoln Laboratory, Massachusetts Institute of Technology, MA 02173-910, P.O. Box 73
基金
美国国家航空航天局;
关键词
D O I
10.1109/23.281527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe the development of a charge-coupled device (CCD) array for use as a soft X-ray (0.4-12 keV) imaging spectrometer for the ASCA (formerly Astro-D) satellite. The CCDs are 420 x 420-pixel frame-transfer devices designed to be closely abutted. to other chips on three sides of the imaging array. The imagers are made on 6500-OMEGA . cm p-type float-zone silicon for depletion depths of about 50 mum under typical CCD bias conditions. The read noise of the CCD is typically 3-4 e- rms at data rates of 50 kHz resulting in an energy resolution E/deltaE almost-equal-to 50 at 5.9 keV. The complete focal-plane sensor consists of a 2 X 2 array of these devices mounted on a common substrate. Radiation damage from energetic protons is mitigated by the use of a narrow potential trough along the center of the CCD channel to confine the small X-ray event charge to a reduced volume and thereby minimize trapping effects. Charged-particle events from the non-X-ray space background are minimized by using a junction on the back of the chip to deplete most of the neutral bulk and draw background charge away from the CCD. Wafer-level device screening at low temperatures and the focal-plane packaging methods are also de scribed.
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [41] SOFT-X-RAY IMAGING OF IMPLODED LINER PLASMAS
    KIUTTU, GF
    DEGNAN, JH
    NUTTELMAN, RA
    REINOVSKY, RE
    WOODALL, DM
    BAKER, WL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 1057 - 1058
  • [42] SOFT-X-RAY IMAGING DIAGNOSTIC ON THE TDEV TOKAMAK
    JANICKI, C
    DECOSTE, R
    NOEL, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10): : 4410 - 4417
  • [43] GAS-TUBE AS RADIATION SOURCE FOR SOFT-X-RAY SPECTROMETER
    VANHATALO, J
    KAIHOLA, L
    SUONINEN, E
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1976, 9 (12): : 1156 - 1157
  • [44] SOFT-X-RAY DOSIMETRY - CALIBRATING THE SOFT-X-RAY CONTACT MICROSCOPY STATION
    GUTTMANN, GD
    HENKE, B
    HOWELLS, MR
    KERNER, JA
    MEDICAL PHYSICS, 1987, 14 (03) : 455 - 455
  • [45] FIRST PLASMON SATELLITE IN SOFT-X-RAY EMISSION SPECTRA OF METALS
    TING, CS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (03): : 271 - &
  • [46] THE X-RAY ASTRONOMY SATELLITE ASCA
    TANAKA, Y
    INOUE, H
    HOLT, SS
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 1994, 46 (03) : L37 - &
  • [47] SOFT-X-RAY MICROSCOPY
    BAEZ, AV
    PHYSICS TODAY, 1986, 39 (05) : 11 - &
  • [48] SOFT-X-RAY CALORIMETER
    PAK, VS
    CHISTYAKOV, SA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (04) : 958 - 961
  • [49] SOFT-X-RAY LASERS
    MATTHEWS, DL
    ROSEN, MD
    SCIENTIFIC AMERICAN, 1988, 259 (06) : 86 - 91
  • [50] SOFT-X-RAY COLLIMATION
    ANANIN, OB
    BYKOVSKII, YA
    ZVERKOV, AK
    FRONDZEI, IY
    KVANTOVAYA ELEKTRONIKA, 1987, 14 (03): : 617 - 618