CCD SOFT-X-RAY IMAGING SPECTROMETER FOR THE ASCA SATELLITE

被引:141
|
作者
BURKE, BE
MOUNTAIN, RW
DANIELS, PJ
COOPER, MJ
DOLAT, VS
机构
[1] The Lincoln Laboratory, Massachusetts Institute of Technology, MA 02173-910, P.O. Box 73
基金
美国国家航空航天局;
关键词
D O I
10.1109/23.281527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe the development of a charge-coupled device (CCD) array for use as a soft X-ray (0.4-12 keV) imaging spectrometer for the ASCA (formerly Astro-D) satellite. The CCDs are 420 x 420-pixel frame-transfer devices designed to be closely abutted. to other chips on three sides of the imaging array. The imagers are made on 6500-OMEGA . cm p-type float-zone silicon for depletion depths of about 50 mum under typical CCD bias conditions. The read noise of the CCD is typically 3-4 e- rms at data rates of 50 kHz resulting in an energy resolution E/deltaE almost-equal-to 50 at 5.9 keV. The complete focal-plane sensor consists of a 2 X 2 array of these devices mounted on a common substrate. Radiation damage from energetic protons is mitigated by the use of a narrow potential trough along the center of the CCD channel to confine the small X-ray event charge to a reduced volume and thereby minimize trapping effects. Charged-particle events from the non-X-ray space background are minimized by using a junction on the back of the chip to deplete most of the neutral bulk and draw background charge away from the CCD. Wafer-level device screening at low temperatures and the focal-plane packaging methods are also de scribed.
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [31] SOFT-X-RAY SPECTROSCOPY (20-150-A) WITH A CONVENTIONAL X-RAY SPECTROMETER
    LUCK, S
    URCH, DS
    PHYSICA SCRIPTA, 1990, 41 (06): : 749 - 753
  • [32] UV AND SOFT-X-RAY IMAGING OF ALCATOR PLASMA
    PETRASSO, R
    SEGUIN, FH
    DAVIS, JM
    KRIEGER, AS
    SILK, JK
    GRANETZ, R
    PARKER, RR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1091 - 1091
  • [33] SOFT-X-RAY IMAGING OF HYDRATED BIOLOGICAL SPECIMENS
    PANESSAWARREN, BJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 447 : 185 - 190
  • [34] IMAGING AT SOFT-X-RAY WAVELENGTHS WITH MICROCHANNEL PLATES
    ZOMBECK, MV
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 58 - 67
  • [35] AMPLIFIED MOS IMAGER FOR SOFT-X-RAY IMAGING
    TAKAYANAGI, I
    NAGAI, K
    TETSUKA, H
    INOUE, Y
    ARAKI, S
    MOCHIMARU, S
    IKETAKI, Y
    HORIKAWA, Y
    MATSUMOTO, K
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1995, 42 (08) : 1425 - 1432
  • [36] AN UNDULATOR SOURCE BEAMLINE FOR SOFT-X-RAY IMAGING
    RARBACK, H
    KRINSKY, S
    MORTAZAVI, P
    SHU, D
    KIRZ, J
    JACOBSEN, C
    HOWELLS, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 159 - 162
  • [37] IMAGING PROPERTIES OF THE SCHWARZSCHILD SOFT-X-RAY MICROSCOPES
    HORIKAWA, Y
    JOURNAL OF MODERN OPTICS, 1993, 40 (10) : 2025 - 2038
  • [38] SOFT-X-RAY IMAGING WITH A NORMAL INCIDENCE MIRROR
    UNDERWOOD, JH
    BARBEE, TW
    NATURE, 1981, 294 (5840) : 429 - 431
  • [39] Soft-X-ray microscopy: Imaging of biological systems
    Jacobsen, C
    BIOMEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 1996, 128 : 91 - 109
  • [40] A SOFT-X-RAY MICROSCOPE USING AN IMAGING DETECTOR
    INOUE, S
    OGAWA, Y
    UEDA, K
    SUMIYA, M
    TAKIGAWA, T
    AOKI, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1990, 29 (01): : L176 - L178