CCD SOFT-X-RAY IMAGING SPECTROMETER FOR THE ASCA SATELLITE

被引:141
|
作者
BURKE, BE
MOUNTAIN, RW
DANIELS, PJ
COOPER, MJ
DOLAT, VS
机构
[1] The Lincoln Laboratory, Massachusetts Institute of Technology, MA 02173-910, P.O. Box 73
基金
美国国家航空航天局;
关键词
D O I
10.1109/23.281527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe the development of a charge-coupled device (CCD) array for use as a soft X-ray (0.4-12 keV) imaging spectrometer for the ASCA (formerly Astro-D) satellite. The CCDs are 420 x 420-pixel frame-transfer devices designed to be closely abutted. to other chips on three sides of the imaging array. The imagers are made on 6500-OMEGA . cm p-type float-zone silicon for depletion depths of about 50 mum under typical CCD bias conditions. The read noise of the CCD is typically 3-4 e- rms at data rates of 50 kHz resulting in an energy resolution E/deltaE almost-equal-to 50 at 5.9 keV. The complete focal-plane sensor consists of a 2 X 2 array of these devices mounted on a common substrate. Radiation damage from energetic protons is mitigated by the use of a narrow potential trough along the center of the CCD channel to confine the small X-ray event charge to a reduced volume and thereby minimize trapping effects. Charged-particle events from the non-X-ray space background are minimized by using a junction on the back of the chip to deplete most of the neutral bulk and draw background charge away from the CCD. Wafer-level device screening at low temperatures and the focal-plane packaging methods are also de scribed.
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [21] SOFT-X-RAY GRAZING-INCIDENCE GRATING SPECTROMETER
    RUSTGI, OP
    BROWN, FC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1974, 64 (04) : 538 - 538
  • [22] ABSOLUTE SOFT-X-RAY MEASUREMENTS WITH A TRANSMISSION GRATING SPECTROMETER
    EIDMANN, K
    KISHIMOTO, T
    HERRMANN, P
    MIZUI, J
    PAKULA, R
    SIGEL, R
    WITKOWSKI, S
    LASER AND PARTICLE BEAMS, 1986, 4 : 521 - 530
  • [23] SOFT-X-RAY PHOTOEMISSION WITH THE SSX-100 SPECTROMETER
    HECHT, MH
    GRUNTHANER, FJ
    PATE, BB
    PIANETTA, P
    ENGELHARDT, M
    JANSEN, W
    BRYSON, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 806 - 809
  • [24] USE OF AN ELECTRON SPECTROMETER AS DETECTOR FOR SOFT-X-RAY SPECTRA
    EBEL, MF
    X-RAY SPECTROMETRY, 1975, 4 (01) : 43 - 46
  • [25] TOWARD A SOFT-X-RAY FOURIER-TRANSFORM SPECTROMETER
    HOWELLS, MR
    FRANK, K
    HUSSAIN, Z
    MOLER, EJ
    REICH, T
    MOLLER, D
    SHIRLEY, DA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3): : 182 - 191
  • [26] Soft X-ray response of a CCD with a grating spectrometer
    Shouho, M
    Katayama, K
    Katayama, H
    Kohmura, T
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Hashimotodani, K
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 85 - 90
  • [27] CCD SOFT-X-RAY OBSERVATIONS OF THE PUPPIS-A SUPERNOVA REMNANT
    BERTHIAUME, GD
    BURROWS, DN
    GARMIRE, GP
    NOUSEK, JA
    ASTROPHYSICAL JOURNAL, 1994, 425 (01): : 132 - 141
  • [28] Soft-x-ray Gabor holography by use of a backilluminated CCD camera
    Univ of Tsukuba, Tsukuba, Japan
    Appl Opt, 29 (7433-7436):
  • [29] Soft-x-ray Gabor holography by use of a backilluminated CCD camera
    Watanabe, N
    Sakurai, K
    Takeuchi, A
    Aoki, S
    APPLIED OPTICS, 1997, 36 (29): : 7433 - 7436
  • [30] Flight X-ray CCD selection for the AXAF CCD imaging spectrometer
    Pivovaroff, M
    Kissel, S
    Bautz, MW
    Prigozhin, GY
    Isobe, T
    Woo, J
    Gregory, JA
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 182 - 193