CCD SOFT-X-RAY IMAGING SPECTROMETER FOR THE ASCA SATELLITE

被引:141
|
作者
BURKE, BE
MOUNTAIN, RW
DANIELS, PJ
COOPER, MJ
DOLAT, VS
机构
[1] The Lincoln Laboratory, Massachusetts Institute of Technology, MA 02173-910, P.O. Box 73
基金
美国国家航空航天局;
关键词
D O I
10.1109/23.281527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe the development of a charge-coupled device (CCD) array for use as a soft X-ray (0.4-12 keV) imaging spectrometer for the ASCA (formerly Astro-D) satellite. The CCDs are 420 x 420-pixel frame-transfer devices designed to be closely abutted. to other chips on three sides of the imaging array. The imagers are made on 6500-OMEGA . cm p-type float-zone silicon for depletion depths of about 50 mum under typical CCD bias conditions. The read noise of the CCD is typically 3-4 e- rms at data rates of 50 kHz resulting in an energy resolution E/deltaE almost-equal-to 50 at 5.9 keV. The complete focal-plane sensor consists of a 2 X 2 array of these devices mounted on a common substrate. Radiation damage from energetic protons is mitigated by the use of a narrow potential trough along the center of the CCD channel to confine the small X-ray event charge to a reduced volume and thereby minimize trapping effects. Charged-particle events from the non-X-ray space background are minimized by using a junction on the back of the chip to deplete most of the neutral bulk and draw background charge away from the CCD. Wafer-level device screening at low temperatures and the focal-plane packaging methods are also de scribed.
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [11] DIELECTRONIC SATELLITE SPECTRA IN SOFT-X-RAY REGION
    GABRIEL, AH
    SPACE SCIENCE REVIEWS, 1972, 13 (4-6) : 655 - &
  • [12] DEVELOPMENTS IN IMAGING IN SOFT-X-RAY MICROSCOPY
    MICHETTE, AG
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1984, 32 (01): : 45 - 48
  • [13] SOFT-X-RAY AND XUV IMAGING WITH A CHARGE-COUPLED DEVICE (CCD)-BASED DETECTOR
    LOTER, NG
    BURSTEIN, P
    KRIEGER, A
    ROSS, D
    HARRISON, D
    MICHELS, DJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 290 : 58 - 61
  • [14] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Pivovaroff, M
    Baganoff, F
    Isobe, T
    Jones, S
    Kissel, S
    LaMarr, B
    Manning, H
    Prigozhin, G
    Ricker, G
    Nousek, J
    Grant, C
    Nishikida, K
    Scholze, F
    Thornagel, R
    Ulm, G
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 210 - 224
  • [15] SOFT-X-RAY IMAGING WITH TOROIDAL MIRRORS
    SAKAYANAGI, Y
    AOKI, S
    APPLIED OPTICS, 1978, 17 (04): : 601 - 603
  • [16] SUBMICRON, SOFT-X-RAY FLUORESCENCE IMAGING
    LAFONTAINE, B
    MACDOWELL, AA
    TAN, ZQ
    WHITE, DL
    TAYLOR, GN
    WOOD, OR
    BJORKHOLM, JE
    TENNANT, DM
    HULBERT, SL
    APPLIED PHYSICS LETTERS, 1995, 66 (03) : 282 - 284
  • [17] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Kissel, S
    Prigozhin, G
    Jones, S
    Isobe, T
    Manning, H
    Pivovaroff, M
    Ricker, G
    Woo, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 170 - 181
  • [18] PROGRESS IN UV SOFT-X-RAY IMAGING
    SCHIRMANN, D
    BOCHER, JL
    LEBRETON, JP
    MENS, A
    SAUNEUF, R
    LASER AND PARTICLE BEAMS, 1992, 10 (04) : 827 - 839
  • [19] A SOFT-X-RAY SPECTROMETER FOR RESONANT INVERSE-PHOTOEMISSION
    WEIBEL, P
    GRIONI, M
    HECHE, C
    BAER, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (07): : 3755 - 3761
  • [20] A NEW TOROIDAL GRATING SPECTROMETER FOR THE SOFT-X-RAY REGION
    ATON, T
    FRANCK, C
    KALLNE, E
    SCHNATTERLY, S
    ZUTAVERN, F
    NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2): : 173 - 175