USE OF PH-ISFET SENSORS DURING EXTRACORPOREAL-CIRCULATION

被引:0
|
作者
CHAUVEAU, N
MORUCCI, JP
VANDENVLEKKERT, HH
DEROOIJ, NF
BARTHELEMY, R
机构
[1] CHU RANGUEIL,CHIRURG EXPTL LAB,F-31052 TOULOUSE,FRANCE
[2] UNIV NEUCHATEL,INST MICROTECHNOL,CH-2000 NEUCHATEL,SWITZERLAND
关键词
D O I
10.1016/0925-4005(90)80254-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the use of an ISFET sensor during extracoporeal circulation (ECC). Initially, the ISFET time response and stability were measured. The flow rate dependency was also determined. The sensor gave a correct response in a few milliseconds which, compared with presently available sensors, is very good. Stability provided to be as good as with Ingold pH sensors (glass electrode). The sensitivity of the sensor used for the experiment was then evaluated precisely, before installation in the ECC arterial line. An Ag/AgCl reference was used. An Ingold sensor was used simultaneously in order to provide comparative measurements. ECC was then performed on a sheep for 6 h. Flow rate stabilized at approximately 31/min and blood temperature was set and regulated to 37°C. Standard laboratory blood gas measurements were performed every 15 min for the first hour and every 30 min thereafter so as to obtain a good control. The results show that standard measurement, Ingold probe and ISFET sensor values vary in the same way and experimentation is continuing. © 1990.
引用
收藏
页码:481 / 484
页数:4
相关论文
共 50 条
  • [41] RELEASE OF LYSOSOMAL HYDROLASES DURING EXTRACORPOREAL-CIRCULATION
    ADDONIZIO, VP
    CHANG, LK
    STRAUSS, JR
    COLMAN, RW
    EDMUNDS, LH
    BRITISH JOURNAL OF SURGERY, 1979, 66 (12) : 884 - 885
  • [42] MONITORING OF HEPARIN ACTIVITY DURING EXTRACORPOREAL-CIRCULATION
    GOMPERTS, ED
    BETHLEHEM, B
    HOCKLEY, J
    SOUTH AFRICAN MEDICAL JOURNAL, 1977, 51 (26): : 973 - 976
  • [43] GLOMERULAR AND TUBULAR CLEARANCE DURING EXTRACORPOREAL-CIRCULATION
    LARCAN, A
    BOULANGE, M
    LAPREVOT.MC
    FONTENAILLE, C
    PABST, JC
    JOURNAL D UROLOGIE ET DE NEPHROLOGIE, 1974, 80 (4-5): : 418 - 424
  • [44] MICROEMBOLI (ME) DURING EXTRACORPOREAL-CIRCULATION (ECC)
    KREBBER, HJ
    HILL, JD
    OSBORN, JJ
    LATRIDIS, A
    THORACIC AND CARDIOVASCULAR SURGEON, 1980, 28 : 29 - 29
  • [45] COAGULATION DEFECTS DURING EXTRACORPOREAL-CIRCULATION IN THE DOG
    ALVAREZ, L
    ESCUDERO, C
    RODRIGUEZ, V
    ORTIZ, J
    CASTILLOOLIVARES, JL
    EUROPEAN SURGICAL RESEARCH, 1987, 19 (02) : 118 - 123
  • [46] HEMODYNAMICS DURING PARTIAL EXTRACORPOREAL-CIRCULATION IN DOG
    SCHRIJEN, F
    GILLE, JP
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1977, 367 (03): : 229 - 233
  • [47] LUNG-MECHANICS DURING EXTRACORPOREAL-CIRCULATION
    GREEN, M
    KELMAN, G
    HANSEN, L
    DRINKER, P
    THORAX, 1974, 29 (02) : 268 - 269
  • [48] PULSATILE EXTRACORPOREAL-CIRCULATION
    KAGE, H
    MERTIG, D
    METZ, H
    KEMSMANN, U
    HELLBERG, K
    HASPER, B
    ARTIFICIAL ORGANS, 1977, 1 (02) : 124 - 124
  • [49] Study on the hysteresis effect of pH-ISFET based on Beckman Φ™ 110 (Si3N4 gate pH-ISFET)
    Chou, JC
    Tseng, YN
    OPTOELECTRONIC MATERIALS AND DEVICES II, 2000, 4078 : 793 - 800
  • [50] PROSTAGLANDINS AND EXTRACORPOREAL-CIRCULATION
    STARLING, MB
    NEUTZE, JM
    PROSTAGLANDINS LEUKOTRIENES AND ESSENTIAL FATTY ACIDS, 1990, 40 (01): : 1 - 8