USE OF PH-ISFET SENSORS DURING EXTRACORPOREAL-CIRCULATION

被引:0
|
作者
CHAUVEAU, N
MORUCCI, JP
VANDENVLEKKERT, HH
DEROOIJ, NF
BARTHELEMY, R
机构
[1] CHU RANGUEIL,CHIRURG EXPTL LAB,F-31052 TOULOUSE,FRANCE
[2] UNIV NEUCHATEL,INST MICROTECHNOL,CH-2000 NEUCHATEL,SWITZERLAND
关键词
D O I
10.1016/0925-4005(90)80254-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the use of an ISFET sensor during extracoporeal circulation (ECC). Initially, the ISFET time response and stability were measured. The flow rate dependency was also determined. The sensor gave a correct response in a few milliseconds which, compared with presently available sensors, is very good. Stability provided to be as good as with Ingold pH sensors (glass electrode). The sensitivity of the sensor used for the experiment was then evaluated precisely, before installation in the ECC arterial line. An Ag/AgCl reference was used. An Ingold sensor was used simultaneously in order to provide comparative measurements. ECC was then performed on a sheep for 6 h. Flow rate stabilized at approximately 31/min and blood temperature was set and regulated to 37°C. Standard laboratory blood gas measurements were performed every 15 min for the first hour and every 30 min thereafter so as to obtain a good control. The results show that standard measurement, Ingold probe and ISFET sensor values vary in the same way and experimentation is continuing. © 1990.
引用
收藏
页码:481 / 484
页数:4
相关论文
共 50 条
  • [21] REDUCTION OF HEMOLYSIS DURING EXTRACORPOREAL-CIRCULATION
    DIDLAKE, RH
    MARKOV, AR
    CLINICAL RESEARCH, 1984, 32 (05): : A860 - A860
  • [22] ULTRAPORE HEMOFILTRATION DURING EXTRACORPOREAL-CIRCULATION
    GERVIN, AS
    MCNEER, JF
    WOLFE, WG
    PUCKETT, CL
    SILVER, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1974, 67 (02): : 237 - 242
  • [23] BRAIN PROTECTION DURING EXTRACORPOREAL-CIRCULATION
    LENZI, GL
    DIPIERO, V
    IACOBONI, M
    PADOVANI, A
    RICCI, M
    BRAGONI, M
    PANTANO, P
    ANNALS OF NEUROLOGY, 1991, 30 (02) : 246 - 246
  • [24] COMPLEMENT ACTIVATION DURING EXTRACORPOREAL-CIRCULATION
    BILFINGER, TV
    ADVANCES IN NEUROIMMUNOLOGY, 1993, 3 (04): : 269 - 276
  • [25] pH-ISFET based urea biosensor
    Pijanowska, DG
    Torbicz, W
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) : 370 - 376
  • [26] INTRAVASCULAR PH-ISFET, A METHOD OF THE FUTURE
    OESEBURG, B
    LIGTENBERG, HCG
    SCHEPEL, SJ
    ZIJLSTRA, WG
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1987, 47 : 31 - 35
  • [27] INVIVO EXPERIMENTS WITH A PH-ISFET ELECTRODE
    SCHEPEL, SJ
    DEROOIJ, NF
    KONING, G
    OESEBURG, B
    ZIJLSTRA, WG
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (01) : 6 - 11
  • [28] pH-ISFET based urea biosensor
    Polish Acad of Sciences, Warsaw, Poland
    Sens Actuators, B Chem, 1 -3 pt 5 (370-376):
  • [29] SOS型pH-ISFET的研制
    汪正孝
    陈克铭
    孙安纳
    张智宏
    李淑英
    化学传感器, 1988, (04) : 40 - 43
  • [30] LEUKOCYTE AND PLATELET ACTIVATION DURING EXTRACORPOREAL-CIRCULATION
    VANOEVEREN, W
    CELLS AND MATERIALS, 1994, 4 (02): : 187 - 195