USE OF PH-ISFET SENSORS DURING EXTRACORPOREAL-CIRCULATION

被引:0
|
作者
CHAUVEAU, N
MORUCCI, JP
VANDENVLEKKERT, HH
DEROOIJ, NF
BARTHELEMY, R
机构
[1] CHU RANGUEIL,CHIRURG EXPTL LAB,F-31052 TOULOUSE,FRANCE
[2] UNIV NEUCHATEL,INST MICROTECHNOL,CH-2000 NEUCHATEL,SWITZERLAND
关键词
D O I
10.1016/0925-4005(90)80254-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the use of an ISFET sensor during extracoporeal circulation (ECC). Initially, the ISFET time response and stability were measured. The flow rate dependency was also determined. The sensor gave a correct response in a few milliseconds which, compared with presently available sensors, is very good. Stability provided to be as good as with Ingold pH sensors (glass electrode). The sensitivity of the sensor used for the experiment was then evaluated precisely, before installation in the ECC arterial line. An Ag/AgCl reference was used. An Ingold sensor was used simultaneously in order to provide comparative measurements. ECC was then performed on a sheep for 6 h. Flow rate stabilized at approximately 31/min and blood temperature was set and regulated to 37°C. Standard laboratory blood gas measurements were performed every 15 min for the first hour and every 30 min thereafter so as to obtain a good control. The results show that standard measurement, Ingold probe and ISFET sensor values vary in the same way and experimentation is continuing. © 1990.
引用
收藏
页码:481 / 484
页数:4
相关论文
共 50 条
  • [31] PULMONARY SURFACTANT LEVEL DURING EXTRACORPOREAL-CIRCULATION
    YOSHIKAWA, N
    EBARA, Y
    SUGATA, H
    YAMANE, M
    SHIGENOBU, M
    SENOO, Y
    TERAMOTO, S
    SUNADA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1975, 39 (09): : 1010 - 1010
  • [32] VASCULAR EFFECTS OF URAPIDIL DURING EXTRACORPOREAL-CIRCULATION
    LEHOT, JJ
    DURAND, PG
    GEORGE, M
    ZABOT, JM
    VILLARD, J
    ESTANOVE, S
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1992, 11 (06): : 619 - 622
  • [33] SOME EFFECTS OF PROSTACYCLIN DURING EXTRACORPOREAL-CIRCULATION
    AREN, C
    RADEGRAN, K
    TEGERNILSSON, AN
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (02): : 185 - 185
  • [34] FUNCTION OF HUMAN PLATELETS DURING EXTRACORPOREAL-CIRCULATION
    HENNESSY, VL
    HICKS, RE
    NIEWIAROWSKI, S
    EDMUNDS, LH
    COLMAN, RW
    AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (06): : H622 - H628
  • [35] HUMAN NEUTROPHIL DEGRANULATION DURING EXTRACORPOREAL-CIRCULATION
    WACHTFOGEL, YT
    KUCICH, U
    GREENPLATE, J
    GLUSZKO, P
    ABRAMS, W
    WEINBAUM, G
    WENGER, RK
    RUCINSKI, B
    NIEWIAROWSKI, S
    EDMUNDS, LH
    COLMAN, RW
    BLOOD, 1987, 69 (01) : 324 - 330
  • [36] pH-ISFET滞后特性的研究
    虞惇
    张玉良
    王贵华
    传感器技术, 1989, (04) : 12 - 17
  • [37] Behavioral modeling of the pH-ISFET temperature influence
    Haiji, B.
    Naimi, S. E.
    Humenyuk, L.
    Launay, J.
    Temple-Boyer, P.
    2007 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-4, 2007, : 419 - +
  • [38] PLASMA-LIPIDS DURING EXTRACORPOREAL-CIRCULATION
    GHIRARDI, P
    MARZO, A
    ROSSI, C
    RESPIGHI, E
    BRUSONI, B
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1975, 70 (04): : 661 - 665
  • [39] FUNCTIONAL CHANGES IN PLATELETS DURING EXTRACORPOREAL-CIRCULATION
    TAMARI, Y
    ALEDORT, L
    PUSZKIN, E
    DEGNAN, TJ
    WAGNER, N
    KAPLITT, MJ
    PEIRCE, EC
    ANNALS OF THORACIC SURGERY, 1975, 19 (06): : 639 - 647
  • [40] INACTIVATION OF HEPARIN DURING EXTRACORPOREAL-CIRCULATION IN INFANTS
    GREEN, TP
    ISHAMSCHOPF, B
    IRMITER, RJ
    SMITH, C
    UDEN, DL
    STEINHORN, RH
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1990, 48 (02) : 148 - 154