VERIFICATION OF A 2-DIMENSIONAL PENCIL BEAM ARC ELECTRON DOSE CALCULATION ALGORITHM

被引:7
|
作者
ANTOLAK, JA
ELKHATIB, E
SCRIMGER, JW
机构
关键词
ELECTRONS; DOSIMETRY; ARC THERAPY; PENCIL BEAMS; LUNG PHANTOM;
D O I
10.1118/1.596960
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry of arced electron beams is of increasing importance because of the increased capabilities of modern linear accelerators. A practical pencil beam algorithm has been developed for arc electron beams and is capable of using computed tomography information for heterogeneity corrections. For homogeneous phantoms, the maximum dose and bremsstrahlung components are predicted very accurately, that is, within 1% of the maximum dose. However, the depth of maximum dose (treatment depth) is predicted to be deeper than measurement, as much as 0.7 cm deeper. For a heterogeneous lung phantom, the discrepancies are as high as 30%, but the accuracy of dose calculation is consistent with conventional stationary pencil beam algorithms. It was concluded that improvements in the dose prediction are possible with more accurate calculations of the pencil beam widths and the incorporation of range straggling into the algorithm.
引用
收藏
页码:1735 / 1742
页数:8
相关论文
共 50 条
  • [1] A TWO-DIMENSIONAL PENCIL-BEAM ALGORITHM FOR CALCULATION OF ARC ELECTRON DOSE DISTRIBUTIONS
    HOGSTROM, KR
    KURUP, RG
    SHIU, AS
    STARKSCHALL, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (03): : 315 - 341
  • [2] DOSIMETRIC EVALUATION OF A 2-DIMENSIONAL, ARC ELECTRON, PENCIL-BEAM ALGORITHM IN WATER AND PMMA
    KURUP, RG
    HOGSTROM, KR
    OTTE, VA
    MOYERS, MF
    TUNG, S
    SHIU, AS
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01): : 127 - 144
  • [3] DOSIMETRIC VERIFICATION OF A 3-D ELECTRON PENCIL BEAM DOSE CALCULATION ALGORITHM
    MCSHAN, DL
    FRAASS, BA
    TENHAKEN, RK
    MEDICAL PHYSICS, 1994, 21 (01) : 13 - 23
  • [4] Systematic verification of a three-dimensional electron beam dose calculation algorithm
    Cheng, A
    Harms, WB
    Gerber, RL
    Wong, JW
    Purdy, JA
    MEDICAL PHYSICS, 1996, 23 (05) : 685 - 693
  • [5] Calculation of physical parameters in pencil beam dose calculation algorithm
    School of Information Science and Engineering, Northeastern University, Shenyang 110004, China
    不详
    不详
    Dongbei Daxue Xuebao, 2008, 3 (437-440): : 437 - 440
  • [6] A PENCIL BEAM ALGORITHM FOR HELIUM ION BEAM DOSE CALCULATION
    Fuchs, H.
    Stroebele, J.
    Schreiner, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S39 - S40
  • [7] Application of the electron pencil beam redefinition algorithm to electron arc therapy
    Chi, Pai-Chun M.
    Hogstrom, Kenneth R.
    Starkschall, George
    Boyd, Robert A.
    Tucker, Susan L.
    Antolak, John A.
    MEDICAL PHYSICS, 2006, 33 (07) : 2369 - 2383
  • [8] A PENCIL BEAM REDEFINITION ALGORITHM FOR ELECTRON DOSE DISTRIBUTIONS
    SHIU, AS
    HOGSTROM, KR
    MEDICAL PHYSICS, 1987, 14 (03) : 473 - 474
  • [9] Dosimetric verification of a pencil beam algorithm for photon dose calculation in the presence of low-density inhomogeneities
    Malisan, MR
    Del Frate, S
    Foti, C
    PHYSICA MEDICA, 1997, 13 : 122 - 125
  • [10] VERIFICATION OF PHOTON DOSE CALCULATION ACCURACY BY THE PENCIL BEAM AND ANALYTICAL ANISOTROPIC ALGORITHM USING MOSFET DETECTORS
    Swinnen, A.
    Nulens, A.
    Verstraete, J.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S414 - S414