Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer

被引:0
|
作者
Yang, Fan [1 ]
Li, Xinxia [1 ]
机构
[1] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. This study intends to construct an error distribution prediction model and analyze its parameters and analyzes the boundary size of CTV extension to PTV, so as to provide a reference for lung cancer patients to control clinical set-up errors and radiotherapy planning. Methods. The prior SBRT set-up error data of 50 patients with lung cancer treated by medical linear accelerator were selected, the Gaussian mixture model was adopted to construct the error distribution prediction model, and the model parameters were solved, based on which the emission boundary from CTV to PTV was calculated. Results. According to the analysis of the model parameters, the spatial distribution of set-up errors is mainly concentrated in the direction of four central points (mu(1) similar to mu(4)), and the error is smaller in the Vrt direction (-0.991 similar to 2.808 mm) and Lat direction (-0.447 similar to 1.337 mm) and larger in the Lng direction (-1.065 similar to 4,463 mm). The possibility of offset of set-up errors in mu(2) and mu(3) direction (0.4440, 02198) is greater than that of mu(1) and mu(4) (0.1767, 0.1595). The standard deviation of set-up errors can reach 0.538 mm. The theoretical expansion boundary of CTV to PTV in Vrt, Lng, and Lat can be calculated as 1.7963 mm, 2.3749 mm, and 0.6066 mm. Conclusion. The GMM Gaussian mixture model can quantitatively describe and predict the set-up errors distribution of lung cancer patients and can obtain the emission boundary of CTV to PTV, which provides a reference for radiotherapy set-up errors control and tumor planning target expansion of lung cancer patients without SBRT.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Set-up accuracy of an external immobilisation system for patients receiving radical radiotherapy for prostate cancer
    d'Aquino, Ashley
    Harrison, Shalini
    Helyer, Sarah
    Dearnaley, David
    McNair, Helen
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2012, 11 (03) : 155 - 161
  • [42] Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
    Erridge, SC
    Seppenwoolde, Y
    Muller, SH
    van Herk, M
    De Jaeger, K
    Belderbos, JSA
    Boersma, LJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) : 75 - 85
  • [43] Alterations of the lymphocytic set-up in elderly patients with cancer
    Motta, M
    Ferlito, L
    Malaguarnera, L
    Vinci, E
    Bosco, S
    Maugeri, D
    Malaguarnera, M
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2003, 36 (01) : 7 - 14
  • [44] Impact of two different Immobilization devices in reducing set-up errors during pelvic radiotherapy
    Al Ajmi, Amna Abdullah
    Cheerathuvalappil, Devisree
    Mirza, Abid Ali
    Vidhyadharan, Abishek
    Pervez, Nadeem
    Al Mandhari, Zahid
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5477 - S5478
  • [45] Set-up errors in radiotherapy for oesophageal cancers - Is electronic portal imaging or conebeam more accurate?
    Hawkins, Maria A.
    Aitken, Alexandra
    Hansen, Vibeke N.
    McNair, Helen A.
    Tait, Diana M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) : 249 - 254
  • [46] Evaluation of set-up errors using CBCT in Head and Neck cancer patients treated with IMRT in UMMC
    Ramachandran, Rangasamy
    Satar, Nur Fadhlina Abdul
    Jamalludin, Zulaikha
    Jong, Wei Loong
    Yuin, Jasmin Loh Pei
    RADIOTHERAPY AND ONCOLOGY, 2024, 197 : S324 - S325
  • [47] THE EFFECT OF SET-UP ERROR ON DELIVERED DOSE IN CURATIVE RADIOTHERAPY FOR NON-SMALL CELL LUNG CANCER
    Xing, Aitang
    Holloway, Lois
    Kumar, Shivani
    Ochoa, Cesar
    Vinod, Shalini K.
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S803 - S804
  • [48] Analysis of set-up errors in 70 consecutive patients treated for rectal carcinoma
    Doeller, C.
    Howischer, P.
    Winkler, P.
    Guss, H.
    Kapp, K. S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 56 - 57
  • [49] Image Guidance Derived Set-up Errors for Head and Neck IMRT Patients
    Richmond, N.
    Pilling, K.
    Thompson, E.
    Walker, C.
    Dunlop, P.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S50 - S51
  • [50] RETRACTED: Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy (Retracted Article)
    Zhu, Luchao
    Liu, Jun
    Li, Yimin
    Yang, Qiaolu
    Wu, Qiong
    Lin, Qing
    Chen, Sijia
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022