Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer

被引:0
|
作者
Yang, Fan [1 ]
Li, Xinxia [1 ]
机构
[1] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. This study intends to construct an error distribution prediction model and analyze its parameters and analyzes the boundary size of CTV extension to PTV, so as to provide a reference for lung cancer patients to control clinical set-up errors and radiotherapy planning. Methods. The prior SBRT set-up error data of 50 patients with lung cancer treated by medical linear accelerator were selected, the Gaussian mixture model was adopted to construct the error distribution prediction model, and the model parameters were solved, based on which the emission boundary from CTV to PTV was calculated. Results. According to the analysis of the model parameters, the spatial distribution of set-up errors is mainly concentrated in the direction of four central points (mu(1) similar to mu(4)), and the error is smaller in the Vrt direction (-0.991 similar to 2.808 mm) and Lat direction (-0.447 similar to 1.337 mm) and larger in the Lng direction (-1.065 similar to 4,463 mm). The possibility of offset of set-up errors in mu(2) and mu(3) direction (0.4440, 02198) is greater than that of mu(1) and mu(4) (0.1767, 0.1595). The standard deviation of set-up errors can reach 0.538 mm. The theoretical expansion boundary of CTV to PTV in Vrt, Lng, and Lat can be calculated as 1.7963 mm, 2.3749 mm, and 0.6066 mm. Conclusion. The GMM Gaussian mixture model can quantitatively describe and predict the set-up errors distribution of lung cancer patients and can obtain the emission boundary of CTV to PTV, which provides a reference for radiotherapy set-up errors control and tumor planning target expansion of lung cancer patients without SBRT.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] IMPACT OF DAILY VOLUMETRIC IMAGING IN REDUCING SET-UP MARGINS FOR LUNG CANCER PATIENTS TREATED WITH CONVENTIONALLY FRACTIONATED RADIOTHERAPY
    Higgins, J.
    Bezjak, A.
    Hope, A.
    Panzarella, T.
    Li, W.
    Craig, T.
    Brade, A.
    Sun, A.
    Cho, J.
    Bissonnette, J. P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S5 - S5
  • [32] Evaluation of set-up verification with the analysis of systematic and random errors in radiotherapy - a study of the Great Poland Cancer Centre
    Szczurek, Lukasz
    Skrobala, Agnieszka
    Piotrowski, Tomasz
    Jodda, Agata
    NUKLEONIKA, 2008, 53 (04) : 167 - 171
  • [33] INFLUENCE OF COMPUTER-SIMULATED SET-UP ERRORS ON DOSE DISTRIBUTIONS IN EXTERNAL RADIOTHERAPY
    ROSENOW, U
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 135 - 135
  • [34] Robustness to set-up errors for treatment plans for superficial tumors in head and neck radiotherapy
    Den Boer, D.
    Slooten, E.
    Wortel, G.
    Lamers-Kuijper, E.
    Hamming-Vrieze, O.
    Van Vliet-Vroegindeweij, C.
    Damen, E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S773 - S773
  • [35] The potential impact of the tension of the pelvic muscles on set-up errors in radiotherapy for pelvic malignancies
    Bujko, K
    Czuchraniuk, P
    Zólciak, A
    Kukolowicz, P
    Kepka, L
    Bielik, A
    ACTA ONCOLOGICA, 2004, 43 (08) : 740 - 743
  • [36] Evaluation of set-up errors in head and neck radiotherapy using electronic portal imaging
    Strbac, Bojan
    Jokic, Vesna Spasic
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (05): : 531 - 536
  • [37] The importance of communication skills required to reduce set-up errors in the radiotherapy planning phase
    Merlotti, A.
    Reali, A.
    Russi, E.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (04) : 395 - 396
  • [38] QA program for IGRT and the role of the RTT: Detection of set-up errors for breast cancer patients
    Goudschaal, K.
    Kamphuis, M.
    Van Kesteren, Z.
    De Jong, R.
    Frank, M.
    Bel, A.
    Van Wieringen, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S186 - S186
  • [39] SET-UP ERRORS IN PROSTATE CANCER PATIENTS TREATED WITH IMRT: RESULTS OF A MONOISTITUTIONAL EXPERIENCE.
    Lupattelli, M.
    Saccia, S.
    Romagnoli, E.
    Milletti, A.
    Pallottini, S.
    Russo, S.
    Paglione, F.
    Tamburi, F.
    Trinari, S.
    Cusco, S.
    Bellavita, R.
    Aristei, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S513 - S513
  • [40] Extended Analysis of Hypofractionated Radiotherapy Set-up Parameters for Breast Cancer Patients on the FAST Trial
    Thomson, A. H.
    Culley, M.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 279 - 279