Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer

被引:0
|
作者
Yang, Fan [1 ]
Li, Xinxia [1 ]
机构
[1] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. This study intends to construct an error distribution prediction model and analyze its parameters and analyzes the boundary size of CTV extension to PTV, so as to provide a reference for lung cancer patients to control clinical set-up errors and radiotherapy planning. Methods. The prior SBRT set-up error data of 50 patients with lung cancer treated by medical linear accelerator were selected, the Gaussian mixture model was adopted to construct the error distribution prediction model, and the model parameters were solved, based on which the emission boundary from CTV to PTV was calculated. Results. According to the analysis of the model parameters, the spatial distribution of set-up errors is mainly concentrated in the direction of four central points (mu(1) similar to mu(4)), and the error is smaller in the Vrt direction (-0.991 similar to 2.808 mm) and Lat direction (-0.447 similar to 1.337 mm) and larger in the Lng direction (-1.065 similar to 4,463 mm). The possibility of offset of set-up errors in mu(2) and mu(3) direction (0.4440, 02198) is greater than that of mu(1) and mu(4) (0.1767, 0.1595). The standard deviation of set-up errors can reach 0.538 mm. The theoretical expansion boundary of CTV to PTV in Vrt, Lng, and Lat can be calculated as 1.7963 mm, 2.3749 mm, and 0.6066 mm. Conclusion. The GMM Gaussian mixture model can quantitatively describe and predict the set-up errors distribution of lung cancer patients and can obtain the emission boundary of CTV to PTV, which provides a reference for radiotherapy set-up errors control and tumor planning target expansion of lung cancer patients without SBRT.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Set-up errors in prostate cancer radiotherapy based on cone-beam computed tomography.
    Trignani, M.
    Caponigro, G.
    Di Biase, M.
    Bagala, P.
    Falco, M. D.
    Vinciguerra, A.
    Augurio, A.
    Di Tommaso, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S723 - S723
  • [22] Analysis of interfraction set-up errors during radiotherapy for head and neck cancers
    Kobayashi, H.
    Saito, Y.
    Hibino, Y.
    Egami, K.
    Ito, M.
    Koizumi, M.
    Katada, K.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S297 - S297
  • [23] Definition of the set-up error using 2D radiographic images and 3D computed tomography and dosimetric effect of set-up errors for head and neck/lung radiotherapy patients
    Ceylan, Cemile
    Arslan, Abdulkadir
    Kafkas, Baris
    Cekickesen, Yucel
    Molaoglu, Figen
    Tecik, Abidin
    Korkmaz, Nursad
    Ayata, Hande
    Kilic, Ayhan
    Ugur, Timur
    Guden, Metin
    Engin, Kayihan
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2015, 30 (03): : 118 - 132
  • [24] The effect of breathing and set-up errors on the cumulative dose to a lung tumor
    Engelsmann, M
    Damen, EMF
    De Jaeger, K
    van Ingen, KM
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) : 95 - 105
  • [25] Radiotherapy technicians inter-observer variability on evaluating set-up errors
    Perez Sanchez, JM.
    Costal, C.
    Pelaez, S.
    Cortes, A.
    Davila, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S271 - S271
  • [26] INFLUENCE OF DAILY SET-UP ERRORS ON DOSE DISTRIBUTION DURING PELVIS RADIOTHERAPY
    Kasabasic, Mladen
    Rajevac, Vedran
    Jurkovic, Slaven
    Ivkovic, Ana
    Sobat, Hrvoje
    Faj, Dario
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2011, 62 (03): : 261 - 267
  • [27] Comparison of immobilisation, imaging and set-up errors during head and neck radiotherapy
    Hay, L.
    Devlin, L.
    Duffton, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2044 - S2045
  • [28] ANALYSIS AND MANAGEMENT OF SET-UP UNCERTAINTIES IN GYNAECOLOGICAL CANCER RADIOTHERAPY
    Jurado Bruggeman, D.
    Munoz, C.
    Marruecos, J.
    Vayreda, J.
    Canals, E.
    Anglada, L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S430 - S431
  • [29] ANALYSIS AND MANAGEMENT OF SET-UP UNCERTAINTIES IN RECTAL CANCER RADIOTHERAPY
    Jurado Bruggeman, D.
    Munoz, C.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S178 - S179
  • [30] Set-up error for conformal radiotherapy of prostate cancer - Reply
    Nutting, CM
    RADIOTHERAPY AND ONCOLOGY, 2000, 56 (03) : 355 - 356