Optimum Radius Size between Cylindrical Ion Trap and Quadrupole Ion Trap

被引:3
|
作者
Chaharborj, Sarkhosh Seddighi [1 ,2 ,3 ]
Kiai, Seyyed Mahmod Sadat [3 ]
Arifin, Norihan Md [1 ]
Gheisari, Yousof [2 ]
机构
[1] Univ Purta Malaysia UPM, Fac Sci, Dept Math, Serdang 43400, Malaysia
[2] Islamic Azad Univ, Dept Math, Bushehr Branch, Bushehr, Iran
[3] Nucl Sci & Technol Res Inst NSTRI, Plasma Phys & Nucl Fus Res Sch, POB 14395, Tehran, Iran
关键词
Quadrupole ion trap; cylindrical ion trap; optimum radius size; fifth order Runge Kutta method; stability regions; ion trajectory; fractional mass resolution;
D O I
10.5478/MSL.2015.6.3.59
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Quadrupole ion trap mass analyzer with a simplified geometry, namely, the cylindrical ion trap (CIT), has been shown to be well-suited using in miniature mass spectrometry and even in mass spectrometer arrays. Computation of stability regions is of particular importance in designing and assembling an ion trap. However, solving CIT equations are rather more difficult and complex than QIT equations, so, analytical and matrix methods have been widely used to calculate the stability regions. In this article we present the results of numerical simulations of the physical properties and the fractional mass resolutions of the confined ions in the first stability region was analyzed by the fifth order Runge-Kutta method (RKM5) at the optimum radius size for both ion traps. Because of similarity the both results, having determining the optimum radius, we can make much easier to design CIT. Also, the simulated results has been performed a high precision in the resolution of trapped ions at the optimum radius size.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [41] Nondestructive Tandem Mass Spectrometry Using a Linear Quadrupole Ion Trap Coupled to a Linear Electrostatic Ion Trap
    Hilger, Ryan T.
    Santini, Robert E.
    McLuckey, Scott A.
    ANALYTICAL CHEMISTRY, 2013, 85 (10) : 5226 - 5232
  • [42] Oligonucleotide mixture, analysis via electrospray and ion/ion reactions in a quadrupole ion trap
    McLuckey, SA
    Wu, J
    Bundy, JL
    Stephenson, JL
    Hurst, GB
    ANALYTICAL CHEMISTRY, 2002, 74 (05) : 976 - 984
  • [43] Performance of a quadrupole ion trap mass spectrometer adapted for ion/ion reaction studies
    Reid, GE
    Wells, JM
    Badman, ER
    McLuckey, SA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 222 (1-3) : 243 - 258
  • [44] Parametric stabilization and cooling of microparticles in a quadrupole ion trap
    Nagornykh, Pavel
    Kane, Bruce E.
    OPTICAL TRAPPING AND OPTICAL MICROMANIPULATION XI, 2014, 9164
  • [45] ONLINE TRAPPING OF IONS INJECTED INTO A QUADRUPOLE ION TRAP
    O, CS
    SCHUESSLER, HA
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1981, 14 (06) : 953 - 960
  • [46] Microfabricated quadrupole ion trap for mass spectrometer applications
    Pau, S
    Pai, CS
    Low, YL
    Moxom, J
    Reilly, PTA
    Whitten, WB
    Ramsey, JM
    PHYSICAL REVIEW LETTERS, 2006, 96 (12)
  • [47] In situ optimization of the electrode geometry of the quadrupole ion trap
    Gill, LA
    Amy, JW
    Vaughn, WE
    Cooks, RG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 188 (1-2) : 87 - 93
  • [48] QUADRUPOLE ION TRAP MASS-SPECTROMETRY OF FULLERENES
    MORAND, KL
    HOKE, SH
    EBERLIN, MN
    PAYNE, G
    COOKS, RG
    ORGANIC MASS SPECTROMETRY, 1992, 27 (03): : 284 - 288
  • [49] NEUTRALIZATION OF SPACE CHARGE IN A QUADRUPOLE RF ION TRAP
    MAJOR, FG
    SCHERMAN.JP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (08): : 838 - &
  • [50] HIGH-PRESSURE CHARACTERISTICS OF QUADRUPOLE ION TRAP
    DAWSON, PH
    LAMBERT, C
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1975, 12 (04): : 941 - 942