A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS

被引:59
|
作者
BLUESTEIN, D
EINAV, S
HWANG, NHC
机构
[1] UNIV MIAMI,DEPT BIOMED ENGN,CORAL GABLES,FL 33124
[2] TEL AVIV UNIV,DEPT FLUID MECH & HEAT TRANSFER,IL-69978 TEL AVIV,ISRAEL
关键词
D O I
10.1016/0021-9290(94)90046-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In vivo cavitation in cardiovascular flow fields may occur under very unusual circumstances as a localized transient phenomenon which are confined to very small legions in the vicinity of the valve body or leaflet surface. The violent collapse of cavitation bubbles induces local erosion that may lead to structural damage. The fluid mechanical factors that may cause in vivo cavitation inception in mechanical heart valve (MHV) prostheses are investigated. It is established that the closing velocity of the leaflet holds the key to MHV cavitation. During the final phase of valve closing, the fluid mass in the gap space between the closing occluder and the valve's body is squeezed into motion by the rapidly approaching boundaries. The flow pattern created by this motion (termed 'squeeze flow'), is found to be related to the valve geometry, and the impact velocity of the closing leaflet. Given the closing velocity of the leaflet and the geometry of the MHV, computational flow dynamics (CFD) are made to determine the velocity distributions in the gap flow field of a bileaflet MHV in the mitral position. A two dimensional, time dependent model of the gap space show that flow velocity in the gap space can reach values as high as 30 m s(-1) in regions near the edge of the inflow surface of the Edwards Duromedics (ED) MHV leaflet. This high speed stream ejected from the gap channel can create the conditions that characterize cavitation. The location of the isolated high speed region corresponds to the surface erosion that was observed in a number of damaged ED-MHV explants.
引用
收藏
页码:1369 / 1378
页数:10
相关论文
共 50 条
  • [41] 1ST CLINICAL-EXPERIENCE WITH A NEW ALL PYROLYTIC CARBON BILEAFLET HEART-VALVE PROSTHESIS
    HEHRLEIN, FW
    GOTTWIK, M
    FRAEDRICH, G
    MULCH, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1980, 79 (04): : 632 - 636
  • [42] Numerical comparison of the closing dynamics of a new trileaflet and a bileaflet mechanical aortic heart valve
    Li, Chi-Pei
    Lu, Po-Chien
    JOURNAL OF ARTIFICIAL ORGANS, 2012, 15 (04) : 364 - 374
  • [43] 6-YEAR FOLLOW-UP AFTER HEART-VALVE REPLACEMENT WITH THE EDWARDS DUROMEDICS BILEAFLET PROSTHESIS
    MORITZ, A
    KLEPETKO, W
    RODLER, S
    FOGER, A
    SCHREINER, W
    GRABENWOGER, F
    WOLNER, E
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1993, 7 (02) : 84 - 90
  • [44] Transient thrombosis of mechanical bileaflet aortic valve prosthesis
    Bouabdallaoui, Nadia
    Achouh, Paul
    Macron, Laurent
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2015, 4 (03) : 298 - +
  • [45] Numerical comparison of the closing dynamics of a new trileaflet and a bileaflet mechanical aortic heart valve
    Chi-Pei Li
    Po-Chien Lu
    Journal of Artificial Organs, 2012, 15 : 364 - 374
  • [46] SYSTOLIC SEQUENTIAL FLOW VELOCITY PROFILES IN 4 CURRENTLY USED BILEAFLET HEART-VALVE PROSTHESES
    VANSON, JAM
    REUL, H
    STEINSEIFER, U
    SCHMITZ, B
    SCHMID, A
    SCHMITZ, C
    RAU, G
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1993, 7 (02) : 107 - 108
  • [47] HEART-VALVE PROSTHESIS AFTER MITRAL COMMISSUROTOMY
    AMOSOV, NM
    DATSENKO, NY
    KHIRURGIYA, 1983, (12): : 5 - &
  • [48] RESULTS OF HEART-VALVE REPLACEMENT WITH THE SORIN PROSTHESIS
    COLOMBO, T
    DONATELLI, F
    QUAINI, E
    VITALI, E
    PELLEGRINI, A
    TEXAS HEART INSTITUTE JOURNAL, 1987, 14 (01) : 77 - 87
  • [49] STEREOSCOPIC PIV OF STEADY FLOW THROUGH A BILEAFLET MECHANICAL HEART VALVE
    Hutchison, C.
    Sullivan, P. E.
    Ethier, C. R.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 1095 - 1096
  • [50] Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve
    Li, Wen-qing
    Gao, Zhi-xin
    Jin, Zhi-jiang
    Qian, Jin-yuan
    APPLIED SCIENCES-BASEL, 2020, 10 (07):