A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS

被引:59
|
作者
BLUESTEIN, D
EINAV, S
HWANG, NHC
机构
[1] UNIV MIAMI,DEPT BIOMED ENGN,CORAL GABLES,FL 33124
[2] TEL AVIV UNIV,DEPT FLUID MECH & HEAT TRANSFER,IL-69978 TEL AVIV,ISRAEL
关键词
D O I
10.1016/0021-9290(94)90046-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In vivo cavitation in cardiovascular flow fields may occur under very unusual circumstances as a localized transient phenomenon which are confined to very small legions in the vicinity of the valve body or leaflet surface. The violent collapse of cavitation bubbles induces local erosion that may lead to structural damage. The fluid mechanical factors that may cause in vivo cavitation inception in mechanical heart valve (MHV) prostheses are investigated. It is established that the closing velocity of the leaflet holds the key to MHV cavitation. During the final phase of valve closing, the fluid mass in the gap space between the closing occluder and the valve's body is squeezed into motion by the rapidly approaching boundaries. The flow pattern created by this motion (termed 'squeeze flow'), is found to be related to the valve geometry, and the impact velocity of the closing leaflet. Given the closing velocity of the leaflet and the geometry of the MHV, computational flow dynamics (CFD) are made to determine the velocity distributions in the gap flow field of a bileaflet MHV in the mitral position. A two dimensional, time dependent model of the gap space show that flow velocity in the gap space can reach values as high as 30 m s(-1) in regions near the edge of the inflow surface of the Edwards Duromedics (ED) MHV leaflet. This high speed stream ejected from the gap channel can create the conditions that characterize cavitation. The location of the isolated high speed region corresponds to the surface erosion that was observed in a number of damaged ED-MHV explants.
引用
收藏
页码:1369 / 1378
页数:10
相关论文
共 50 条
  • [31] CONTROL OF PATIENTS WITH HEART-VALVE PROSTHESIS
    ENGLERT, M
    MINERVA MEDICA, 1977, 68 (60) : 4053 - 4058
  • [32] Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis
    Bagno, Andrea
    Anzil, Federico
    Buselli, Roberto
    Pesavento, Elena
    Tarzia, Vincenzo
    Pengo, Vittorio
    Bottio, Tomaso
    Gerosa, Gino
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (03) : 172 - 181
  • [33] TRIPLE HEART-VALVE PROSTHESIS AND PREGNANCY
    ANDRINOPOULOS, GC
    ARIAS, F
    OBSTETRICS AND GYNECOLOGY, 1980, 55 (06): : 762 - 764
  • [34] PERICARDIAL PROSTHESIS FOR HEART-VALVE REPLACEMENT
    AUPART, M
    MEURISSE, Y
    DREYFUS, X
    SIRINELLI, A
    NEVILLE, P
    ROUCHET, S
    MARCHAND, M
    PRESSE MEDICALE, 1995, 24 (13): : 647 - 650
  • [35] Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis
    Andrea Bagno
    Federico Anzil
    Roberto Buselli
    Elena Pesavento
    Vincenzo Tarzia
    Vittorio Pengo
    Tomaso Bottio
    Gino Gerosa
    Journal of Artificial Organs, 2009, 12 : 172 - 181
  • [36] PREGNANCY AND TRIPLE HEART-VALVE PROSTHESIS
    DUFFY, BL
    ANAESTHESIA AND INTENSIVE CARE, 1982, 10 (01) : 59 - 61
  • [37] INCIDENCE AND FREQUENCY OF CEREBRAL EMBOLIC SIGNALS IN PATIENTS WITH A SIMILAR BILEAFLET MECHANICAL HEART-VALVE
    BRAEKKEN, SK
    RUSSELL, D
    BRUCHER, R
    SVENNEVIG, J
    STROKE, 1995, 26 (07) : 1225 - 1230
  • [38] Experimental investigation of flow through a bileaflet mechanical heart valve
    Mejia, J.
    Oshkai, P.
    ADVANCES IN FLUID MECHANICS VI, 2006, 52 : 593 - +
  • [39] Passive flow control of bileaflet mechanical heart valve leakage flow
    Dasi, Lakshmi P.
    Murphy, David W.
    Glezer, An
    Yoganathan, Ajit P.
    JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1166 - 1173
  • [40] The Apex bileaflet mechanical heart valve
    Mohammadi H.
    Bhullar A.
    Journal of Medical Engineering and Technology, 2021, 45 (01): : 41 - 51