Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study

被引:9
|
作者
Prabhudesai, Sumant [1 ]
Kanjani, Amruta [2 ]
Bhagat, Isha [3 ]
Ravikumar, Karnam G. [4 ]
Ramachandran, Bala [4 ]
机构
[1] Royal Manchester Childrens Hosp, Oxford Rd, Manchester M13 9WL, Lancs, England
[2] Columbia Asia Hosp, Ahmedebad, Gujrat, India
[3] PD Hinduja Natl Hosp & Med Res Ctr, Bombay, Maharashtra, India
[4] Kanchi Kamakoti CHILDS Trust Hosp, Madras, Tamil Nadu, India
关键词
Children; continuous glucose monitoring system; septic shock;
D O I
10.4103/0972-5229.169331
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. Subjects and Methods: Children aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG). Results: Nineteen children were included, and 235 pairs of BG-CGMS readings were obtained. BG and CGMS had a correlation coefficient of 0.61 (P < 0.001) and a median relative absolute difference of 17.29%. On Clarke's error grid analysis, 222 ( 94.5%) readings were in the clinically acceptable zones (A and B). When BG was < 70, 70-180, and > 180 mg/dL, 44%, 100%, and 76.9% readings were in zones A and B, respectively (P < 0.001). The accuracy of CGMS was not affected by the presence of edema, acidosis, vasopressors, steroids, or renal replacement therapy. On receiver operating characteristics curve analysis, a CGMS reading < 97 mg/dL predicted hypoglycemia (sensitivity 85.2%, specificity 75%, area under the curve [AUC] =0.85). A reading > 141 mg/dL predicted hyperglycemia (sensitivity 84.6%, specificity 89.6%, AUC =0.87). Conclusion: CGMS provides a fairly, accurate estimate of BG in children with septic shock. It is unaffected by a variety of clinical variables. The accuracy over extremes of blood sugar may be a concern. We recommend larger studies to evaluate its use for the early detection of hypoglycemia and hyperglycemia.
引用
收藏
页码:642 / 647
页数:6
相关论文
共 50 条
  • [41] UTILISATION OF INTERMITTENT AND REAL-TIME CONTINUOUS BLOOD GLUCOSE MONITORING IN THE IRISH HEALTHCARE SYSTEM
    Gorry, C.
    Smith, A.
    Doran, S.
    Clarke, S.
    Barry, M.
    VALUE IN HEALTH, 2023, 26 (12) : S265 - S265
  • [42] Real-time monitoring system for accuracy of precision seeder
    Song, Peng
    Zhang, Junxiong
    Li, Wei
    Zhang, Xiaochao
    Fang, Xianfa
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2011, 42 (02): : 71 - 74
  • [43] Postprandial instead of preprandial calibration allows better accuracy of real-time continuous glucose monitoring (CGM)
    Capel, I.
    Pons, B.
    Hernando, M. E.
    Garcia, G.
    Brugues, E.
    de Leiva, A.
    Gomez, E.
    Prados, A.
    Erdozain, L.
    Rigla, M.
    DIABETOLOGIA, 2007, 50 : S419 - S419
  • [44] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Mohammed Abdul Wasiq
    Sushree Smita Behura
    Swaranjika Sahoo
    Santosh Kumar Panda
    European Journal of Pediatrics, 2023, 182 : 1083 - 1087
  • [45] ASSESSMENT OF THE ACCURACY OF REAL-TIME CONTINUOUS GLUCOSE MONITORING AND ITS CORRELATED FACTORS IN CRITICALLY ILL PATIENTS
    MZ Lu
    Y Kang
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [46] Accuracy to detect neonatal hyperglycaemia using real-time continuous glucose monitoring during postoperative period
    Wasiq, Mohammed Abdul
    Behura, Sushree Smita
    Sahoo, Swaranjika
    Panda, Santosh Kumar
    EUROPEAN JOURNAL OF PEDIATRICS, 2023, 182 (03) : 1083 - 1087
  • [47] Assessment of glucose kinetics with real-time continuous glucose monitoring during labor
    Maki, Jota
    Eto, Eriko
    Tamada, Shoko
    Mitsui, Takashi
    Hayata, Kei
    Nakamura, Keiichiro
    Hiramatsu, Yuji
    Masuyama, Hisashi
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2019, 45 (09) : 1851 - 1859
  • [48] Continuous real-time monitoring and recording of glycemia during scuba diving: pilot study
    Pieri, Massimo
    Cialoni, Danilo
    Marroni, Alessandro
    UNDERSEA AND HYPERBARIC MEDICINE, 2016, 43 (03) : 265 - 272
  • [49] Caregivers of Children with Type 1 Diabetes Value Real-Time Functions of Continuous Glucose Monitoring
    Wong, Jenise C.
    Abdulhussein, Fatema
    Yeung, Brittany J.
    Velazquez, Edgar J.
    DIABETES, 2019, 68
  • [50] Real-Time Continuous Glucose Monitoring in the Hospital: A Real-World Experience
    Bagsic, Samantha R. Spierling R.
    Fortmann, Addie L. L.
    Belasco, Rebekah
    Bastian, Alessandra
    Lohnes, Suzanne
    Ritko, Anna
    Sandoval, Haley
    Chichmarenko, Mariya
    Soriano, Emily C. C.
    Talavera, Laura
    Philis-Tsimikas, Athena
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03): : 656 - 666