Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study

被引:9
|
作者
Prabhudesai, Sumant [1 ]
Kanjani, Amruta [2 ]
Bhagat, Isha [3 ]
Ravikumar, Karnam G. [4 ]
Ramachandran, Bala [4 ]
机构
[1] Royal Manchester Childrens Hosp, Oxford Rd, Manchester M13 9WL, Lancs, England
[2] Columbia Asia Hosp, Ahmedebad, Gujrat, India
[3] PD Hinduja Natl Hosp & Med Res Ctr, Bombay, Maharashtra, India
[4] Kanchi Kamakoti CHILDS Trust Hosp, Madras, Tamil Nadu, India
关键词
Children; continuous glucose monitoring system; septic shock;
D O I
10.4103/0972-5229.169331
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. Subjects and Methods: Children aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG). Results: Nineteen children were included, and 235 pairs of BG-CGMS readings were obtained. BG and CGMS had a correlation coefficient of 0.61 (P < 0.001) and a median relative absolute difference of 17.29%. On Clarke's error grid analysis, 222 ( 94.5%) readings were in the clinically acceptable zones (A and B). When BG was < 70, 70-180, and > 180 mg/dL, 44%, 100%, and 76.9% readings were in zones A and B, respectively (P < 0.001). The accuracy of CGMS was not affected by the presence of edema, acidosis, vasopressors, steroids, or renal replacement therapy. On receiver operating characteristics curve analysis, a CGMS reading < 97 mg/dL predicted hypoglycemia (sensitivity 85.2%, specificity 75%, area under the curve [AUC] =0.85). A reading > 141 mg/dL predicted hyperglycemia (sensitivity 84.6%, specificity 89.6%, AUC =0.87). Conclusion: CGMS provides a fairly, accurate estimate of BG in children with septic shock. It is unaffected by a variety of clinical variables. The accuracy over extremes of blood sugar may be a concern. We recommend larger studies to evaluate its use for the early detection of hypoglycemia and hyperglycemia.
引用
收藏
页码:642 / 647
页数:6
相关论文
共 50 条
  • [21] Practical Aspects of Real-Time Continuous Glucose Monitoring
    Gilliam, Lisa K.
    Hirsch, Irl B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S75 - S82
  • [22] Real-Time Continuous Glucose Monitoring in Preterm Infants
    Joseph, Rachel
    Rosa, Jenna Hope-Altomari
    NEONATAL NETWORK, 2022, 41 (06): : 376 - 376
  • [23] Reliability of real-time continuous glucose monitoring in infants
    Tomotaki, Seiichi
    Toyoshima, Katsuaki
    Shimokaze, Tomoyuki
    Kawai, Masahiko
    PEDIATRICS INTERNATIONAL, 2019, 61 (10) : 1001 - 1006
  • [24] Clinical Use of Real-Time Continuous Glucose Monitoring
    Battelino, Tadej
    Bolinder, Jan
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 218 - 222
  • [25] Benefits of Real-Time Continuous Glucose Monitoring in Pregnancy
    Yamamoto, Jennifer M.
    Murphy, Helen R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S8 - S14
  • [26] The benefits and accuracy of real-time continuous glucose monitoring in children and adolescents with type 1 diabetes attending a summer camp
    Kondo, Tatsuya
    Senokuchi, Takafumi
    Morinaga, Jun
    Miyashita, Azusa
    Yano, Mayumi
    Takeda, Haruo
    Nishida, Kenro
    Kubota, Naoto
    JOURNAL OF DIABETES INVESTIGATION, 2025, 16 (01) : 154 - 162
  • [27] Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review
    Hoeks, L. B. E. A.
    Greven, W. L.
    de Valk, H. W.
    DIABETIC MEDICINE, 2011, 28 (04) : 386 - 394
  • [28] A Pilot Study of the Feasibility and Accuracy of Inpatient Continuous Glucose Monitoring
    Nair, Bala G.
    Dellinger, E. Patchen
    Flum, David R.
    Rooke, G. Alec
    Hirsch, Irl B.
    DIABETES CARE, 2020, 43 (11) : E168 - E169
  • [29] The accuracy and efficacy of Real-Time Continuous Glucose Monitoring sensor in patients with type 1 diabetes
    Mastrototaro, John
    Shin, John
    Marcus, Alan
    Sulur, Giri
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (05) : 385 - 390
  • [30] Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring (CGM) System during Elective Abdominal Surgery
    Tripyla, Afroditi
    Herzig, David
    Nakas, Christos
    Dehais, Joachim
    Andreou, Andreas
    Amiet, Franziska
    Gloor, Beat
    Vogt, Andreas
    Bally, Lia
    DIABETES, 2020, 69