Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study

被引:9
|
作者
Prabhudesai, Sumant [1 ]
Kanjani, Amruta [2 ]
Bhagat, Isha [3 ]
Ravikumar, Karnam G. [4 ]
Ramachandran, Bala [4 ]
机构
[1] Royal Manchester Childrens Hosp, Oxford Rd, Manchester M13 9WL, Lancs, England
[2] Columbia Asia Hosp, Ahmedebad, Gujrat, India
[3] PD Hinduja Natl Hosp & Med Res Ctr, Bombay, Maharashtra, India
[4] Kanchi Kamakoti CHILDS Trust Hosp, Madras, Tamil Nadu, India
关键词
Children; continuous glucose monitoring system; septic shock;
D O I
10.4103/0972-5229.169331
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. Subjects and Methods: Children aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG). Results: Nineteen children were included, and 235 pairs of BG-CGMS readings were obtained. BG and CGMS had a correlation coefficient of 0.61 (P < 0.001) and a median relative absolute difference of 17.29%. On Clarke's error grid analysis, 222 ( 94.5%) readings were in the clinically acceptable zones (A and B). When BG was < 70, 70-180, and > 180 mg/dL, 44%, 100%, and 76.9% readings were in zones A and B, respectively (P < 0.001). The accuracy of CGMS was not affected by the presence of edema, acidosis, vasopressors, steroids, or renal replacement therapy. On receiver operating characteristics curve analysis, a CGMS reading < 97 mg/dL predicted hypoglycemia (sensitivity 85.2%, specificity 75%, area under the curve [AUC] =0.85). A reading > 141 mg/dL predicted hyperglycemia (sensitivity 84.6%, specificity 89.6%, AUC =0.87). Conclusion: CGMS provides a fairly, accurate estimate of BG in children with septic shock. It is unaffected by a variety of clinical variables. The accuracy over extremes of blood sugar may be a concern. We recommend larger studies to evaluate its use for the early detection of hypoglycemia and hyperglycemia.
引用
收藏
页码:642 / 647
页数:6
相关论文
共 50 条
  • [32] First experiences with the continuous real-time glucose monitoring system (Guardian REAL-time CGMS) in a cat with Diabetes mellitus
    Moretti, S.
    Zini, E.
    Tschuor, F.
    Reusch, C. E.
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2009, 151 (01): : 27 - 30
  • [33] New perspectives on real-time continuous glucose monitoring Comment
    Stechova, Katerina
    LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (04): : 235 - 236
  • [34] Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System
    Ji, Linong
    Guo, Lixin
    Zhang, Junqing
    Li, Yufeng
    Chen, Zhiyan
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 208 - 213
  • [35] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [36] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [37] Is reimbursement for alerts and real-time continuous glucose monitoring needed?
    Norgaard, Kirsten
    Schmidt, Signe
    LANCET, 2021, 397 (10291): : 2230 - 2232
  • [38] Design and implementation of real-time continuous glucose monitoring instrument
    实时动态血糖监测器的设计与实现
    Liu, Hongying (liu_hongying@163.com), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [39] Sustainable Use of a Real-Time Continuous Glucose Monitoring System from 2018 to 2020
    van der Linden, Joost
    Welsh, John B.
    Walker, Tomas C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (07) : 508 - 511
  • [40] Evaluation of a Novel Real-Time Continuous Glucose-Monitoring System for Use in Cats
    Moretti, S.
    Tschuor, F.
    Osto, M.
    Franchini, M.
    Wichert, B.
    Ackermann, M.
    Lutz, T. A.
    Reusch, C. E.
    Zini, E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (01): : 120 - 126