PRELIMINARY EXPERIENCE WITH INTRAPARTUM FETAL PULSE OXIMETRY IN HUMANS

被引:0
|
作者
DILDY, GA
CLARK, SL
LOUCKS, CA
机构
[1] UNIV UTAH,SCH MED,DEPT OBSTET & GYNECOL,DIV MATERNAL FETAL MED,SALT LAKE CITY,UT 84112
[2] INTERMT HLTH CARE PERINATAL CTR,SALT LAKE CITY,UT
来源
OBSTETRICS AND GYNECOLOGY | 1993年 / 81卷 / 04期
关键词
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Electronic fetal heart rate (FHR) monitoring is commonly used to assess fetal well-being during labor. Nonreassuring patterns in many cases are associated with normal fetal acid-base condition, leading to unnecessary operative intervention. Fetal pulse oximetry has several potential advantages over FHR monitoring because it assesses not only pulse, but also arterial oxygen saturation and tissue perfusion. We describe our preliminary experience with the Nellcor N-400 Fetal Oxygen Saturation Monitor and FS-10 Oxisensor in 73 subjects during active labor at term. The mean (+/- standard deviation) duration of monitoring was 161.4 +/- 106.0 minutes, with sensor contact achieved 67.3 +/- 22.5% of the time during labor. Data were successfully recorded in all patients, with a reliable signal obtained 50.1 +/- 21.6% of the time during labor. The mean fetal oxygen saturation was 57.9 +/- 10.0%. The potential for research and clinical applications appears promising with further sensor and monitor development.
引用
收藏
页码:630 / 635
页数:6
相关论文
共 50 条
  • [11] Fetal pulse oximetry: Duration of desaturation and intrapartum outcome
    Bloom, SL
    Swindle, RG
    Mcintire, DD
    Leveno, KJ
    OBSTETRICS AND GYNECOLOGY, 1999, 93 (06): : 1036 - 1040
  • [12] The relevance of intrapartum fetal pulse oximetry in the presence of fetal cardiac arrhythmia
    Afriat, R
    Bercau, G
    Bidat, L
    Lesobre, R
    Sauvanet, E
    Freund, M
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1999, 78 (09) : 827 - 828
  • [13] INTRAPARTUM FETAL PULSE OXIMETRY IN THE PRESENCE OF FETAL CARDIAC-ARRHYTHMIA
    DILDY, GA
    LOUCKS, CA
    CLARK, SL
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (06) : 1609 - 1611
  • [14] Evaluation of intrapartum fetal well-being by fetal pulse oximetry
    Amano, K
    Hirano, S
    Nishijima, M
    LABOR AND DELIVERY, 1998, : 396 - 399
  • [15] Intrapartum fetal oximetry
    Sato, I
    Izumi, A
    LABOR AND DELIVERY, 1998, : 140 - 143
  • [16] Intrapartum surveillance of IUGR fetuses with cardiotocography and fetal pulse oximetry
    Siristatidis, C
    Salamalekis, E
    Vitoratos, N
    Loghis, C
    Salloum, J
    Kassanos, D
    Panayotopoulos, N
    Creatsas, G
    BIOLOGY OF THE NEONATE, 2003, 83 (03): : 162 - 165
  • [17] Fetal pulse oximetry:: clinical evaluation during intrapartum surveillance
    Kühnert, M
    Seelbach-Göbel, B
    2ND INTERNATIONAL CONGRESS ON NEW TECHNOLOGIES IN REPRODUCTIVE MEDICINE, NEONATOLOGY AND GYNECOLOGY, 1999, : 103 - 110
  • [18] The efficacy of intrapartum fetal surveillance when fetal pulse oximetry is added to cardiotocography
    vandenBerg, PP
    Dildy, GA
    Luttkus, A
    Mason, GC
    Harvey, CJ
    Nijhuis, JG
    Jongsma, HW
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S67 - S71
  • [19] Intrapartum fetal pulse oximetry. Part 2: Clinical application
    Yam, J
    Chua, S
    Arulkumaran, S
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2000, 55 (03) : 173 - 183
  • [20] Advances in intrapartum fetal pulse oximetry: New generation sensors.
    Davies, MG
    Greene, KR
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1996, 103 (11): : 1166 - 1166