PRELIMINARY EXPERIENCE WITH INTRAPARTUM FETAL PULSE OXIMETRY IN HUMANS

被引:0
|
作者
DILDY, GA
CLARK, SL
LOUCKS, CA
机构
[1] UNIV UTAH,SCH MED,DEPT OBSTET & GYNECOL,DIV MATERNAL FETAL MED,SALT LAKE CITY,UT 84112
[2] INTERMT HLTH CARE PERINATAL CTR,SALT LAKE CITY,UT
来源
OBSTETRICS AND GYNECOLOGY | 1993年 / 81卷 / 04期
关键词
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Electronic fetal heart rate (FHR) monitoring is commonly used to assess fetal well-being during labor. Nonreassuring patterns in many cases are associated with normal fetal acid-base condition, leading to unnecessary operative intervention. Fetal pulse oximetry has several potential advantages over FHR monitoring because it assesses not only pulse, but also arterial oxygen saturation and tissue perfusion. We describe our preliminary experience with the Nellcor N-400 Fetal Oxygen Saturation Monitor and FS-10 Oxisensor in 73 subjects during active labor at term. The mean (+/- standard deviation) duration of monitoring was 161.4 +/- 106.0 minutes, with sensor contact achieved 67.3 +/- 22.5% of the time during labor. Data were successfully recorded in all patients, with a reliable signal obtained 50.1 +/- 21.6% of the time during labor. The mean fetal oxygen saturation was 57.9 +/- 10.0%. The potential for research and clinical applications appears promising with further sensor and monitor development.
引用
收藏
页码:630 / 635
页数:6
相关论文
共 50 条
  • [41] Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review
    Uchida, Toshiyuki
    Kanayama, Naohiro
    Kawai, Kenta
    Mukai, Mari
    Suzuki, Kazunao
    Itoh, Hiroaki
    Niwayama, Masatsugu
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2018, 44 (12) : 2127 - 2134
  • [42] INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME
    DILDY, GA
    VANDENBERG, PP
    KATZ, M
    CLARK, SL
    JONGSMA, HW
    NIJHUIS, JG
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) : 679 - 684
  • [43] Effects of maternal oxygen administration on fetal pulse oximetry measured by fetal pulse oximetry
    Haydon, Michael L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 196 (04)
  • [44] The unresolved role of cardiotocography (CTG), fetal ECG (STAN) and intrapartum fetal pulse oximetry (IFPO) as diagnostic methods for fetal hypoxia
    Sholapurkar, S. L.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2014, 34 (08) : 757 - 757
  • [45] Fetal transmission pulse oximetry
    Masin, DI
    Paulsen, AW
    Brouillard, RG
    Iyer, VK
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2326 - 2329
  • [46] Antepartum fetal pulse oximetry
    Lewinsky, RM
    Fine, I
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S81 - S85
  • [47] Fetal pulse oximetry - In reply
    Lockwood, CJ
    Artal, R
    OBSTETRICS AND GYNECOLOGY, 2002, 99 (03): : 515 - 516
  • [48] FETAL MONITORING WITH PULSE OXIMETRY
    JOHNSON, N
    JOHNSON, VA
    FISHER, J
    JOBBINGS, B
    BANNISTER, J
    LILFORD, RJ
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (01): : 36 - 41
  • [49] Accuracy of fetal pulse oximetry
    Luttkus, AK
    Lübke, M
    Büscher, U
    Porath, M
    Dudenhausen, JW
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2002, 81 (05) : 417 - 423
  • [50] Reusable sensors in intrapartum foetal reflection pulse oximetry
    Arikan, MG
    Haas, J
    Giuliani, A
    Haeusler, M
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7): : 457 - 462