DEPTH-DOSE FLATTENING OF ELECTRON-BEAMS USING A WIRE MESH BOLUS

被引:9
|
作者
ALASTI, H
GALBRAITH, DM
机构
[1] Princess Margaret Hospital, Toronto, M4X 1K9
关键词
D O I
10.1118/1.597432
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A common problem with low-energy electron beams (< 15 MeV) is their low surface dose when the incident electrons are monodirectional. This makes it difficult to deliver a uniform dose to tumor with any precision, limiting the clinical usefulness of such beams. A practical method is presented for greatly increasing the tissue depth enclosed by the 95% isodose region, while delivering the entire dose in a single uninterrupted treatment. Beam modification is achieved by placing a wire mesh of high atomic number (Z) on the treatment surface throughout the treatment. Electron beams of energies 6, 9, and 13 MeV are modified to produce a near uniform dose from the surface to the original depth of maximum, approximately doubling the depth enclosed by the 95% isodose. These beams have a step-function-like depth dose and can be arranged to deliver a constant dose to tumor located at varying depths while simultaneously sparing deeper tissues which are also located at varying depths. A single mesh design was found to be suitable for all energies.
引用
收藏
页码:1675 / 1683
页数:9
相关论文
共 50 条
  • [31] ELECTRON DEPTH-DOSE DISTRIBUTION MEASUREMENTS IN FINITE POLYSTYRENE SLABS
    ROSENSTE.M
    SILVERMA.J
    EISEN, H
    JOURNAL OF APPLIED PHYSICS, 1972, 43 (07) : 3191 - &
  • [32] ELECTRON-BEAM CENTRAL AXIS DEPTH-DOSE MEASUREMENTS
    KIRBY, TH
    GASTORF, RJ
    HANSON, WF
    SHALEK, RJ
    HAZLE, JD
    MEDICAL PHYSICS, 1984, 11 (03) : 399 - 400
  • [33] MEDULLOBLASTOMA THERAPY USING ELECTRON-BEAMS
    VIJAYAKUMAR, S
    MULLERRUNKEL, R
    RADIOLOGY, 1985, 157 (02) : 541 - 542
  • [34] DOSE DISTRIBUTIONS IN HIGH-ENERGY ELECTRON-BEAMS
    BOAG, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 671 - &
  • [35] CONVOLUTION METHOD OF DOSE CALCULATION APPLIED TO ELECTRON-BEAMS
    WOO, MK
    CUNNINGHAM, JR
    MEDICAL PHYSICS, 1987, 14 (04) : 705 - 705
  • [36] Characterization of a multilayer ionization chamber for relative depth-dose curves in particle beams
    Vai, A.
    Maestri, D.
    Magro, G.
    Mairani, A.
    Mastella, E.
    Mirandola, A.
    Molinelli, S.
    Russo, S.
    Togno, M.
    La Civita, S.
    Ciocca, M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S473 - S473
  • [37] CONTROLLED DEPTH APPLICATIONS OF MEDIUM-ENERGY ELECTRON-BEAMS
    NABLO, SV
    CLEGHORN, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 389 - POLY
  • [39] Role of the interaction processes in the depth-dose distribution of proton beams in liquid water
    Garcia-Molina, Rafael
    Abril, Isabel
    de Vera, Pablo
    Kyriakou, Ioanna
    Emfietzoglou, Dimitris
    1ST NANO-IBCT CONFERENCE 2011 - RADIATION DAMAGE OF BIOMOLECULAR SYSTEMS: NANOSCALE INSIGHTS INTO ION BEAM CANCER THERAPY, 2012, 373
  • [40] A depth-dose measuring device using a multichannel scintillating fiber array for electron beam therapy
    Aoyama, T
    Koyama, S
    Tsuzaka, M
    Maekoshi, H
    MEDICAL PHYSICS, 1997, 24 (08) : 1235 - 1239