DEPTH-DOSE FLATTENING OF ELECTRON-BEAMS USING A WIRE MESH BOLUS

被引:9
|
作者
ALASTI, H
GALBRAITH, DM
机构
[1] Princess Margaret Hospital, Toronto, M4X 1K9
关键词
D O I
10.1118/1.597432
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A common problem with low-energy electron beams (< 15 MeV) is their low surface dose when the incident electrons are monodirectional. This makes it difficult to deliver a uniform dose to tumor with any precision, limiting the clinical usefulness of such beams. A practical method is presented for greatly increasing the tissue depth enclosed by the 95% isodose region, while delivering the entire dose in a single uninterrupted treatment. Beam modification is achieved by placing a wire mesh of high atomic number (Z) on the treatment surface throughout the treatment. Electron beams of energies 6, 9, and 13 MeV are modified to produce a near uniform dose from the surface to the original depth of maximum, approximately doubling the depth enclosed by the 95% isodose. These beams have a step-function-like depth dose and can be arranged to deliver a constant dose to tumor located at varying depths while simultaneously sparing deeper tissues which are also located at varying depths. A single mesh design was found to be suitable for all energies.
引用
收藏
页码:1675 / 1683
页数:9
相关论文
共 50 条
  • [41] Calculation of depth-dose distribution of intermediate energy heavy-ion beams
    Li, Q
    Wei, ZQ
    Li, WJ
    CHINESE SCIENCE BULLETIN, 2002, 47 (20): : 1708 - 1710
  • [42] INFLUENCE OF COLLIMATING DESIGN ON CENTRAL AXIS DEPTH DOSE OF 10-40 MEV ELECTRON-BEAMS
    HAMMOUDAH, M
    OSMAN, G
    JOURNAL OF MEDICINE, 1977, 8 (3-4) : 219 - 238
  • [43] ELECTRON DEPTH-DOSE DISTRIBUTION MEASUREMENTS IN POLYSTYRENE AS A FUNCTION OF ANGLE AND THICKNESS
    ROSENSTE.M
    EISEN, H
    SILVERMA.J
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (01): : 397 - &
  • [44] The depth-dose curve depends on the inhomogeneity of the material irradiated by electron beam
    Nguyen Anh Tuan
    Chau Van Tao
    Rangacharyulu, Chary
    RADIATION PHYSICS AND CHEMISTRY, 2019, 163 : 22 - 25
  • [45] Depth-dose distribution of proton beams using inelastic-collision cross sections of liquid water
    Juan, C. Candela
    Crispin-Ortuzar, M.
    Aslaninejad, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (02): : 189 - 196
  • [46] PARALLEL-WIRE MEANDER LINE DEFLECTION CIRCUIT FOR ELECTRON-BEAMS
    YAMAMOTO, Y
    HAGIWARA, Y
    IWAI, T
    FUJISAWA, K
    ELECTRONICS LETTERS, 1980, 16 (17) : 650 - 656
  • [47] ELECTRON DEPTH-DOSE DISTRIBUTIONS IN WATER, IRON AND LEAD - THE GEPTS SYSTEM
    CHIBANI, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 101 (04): : 357 - 378
  • [48] THE SPECTRAL DEPENDENCE OF ELECTRON CENTRAL-AXIS DEPTH-DOSE CURVES
    DEASY, JO
    ALMOND, PR
    MCELLISTREM, MT
    MEDICAL PHYSICS, 1994, 21 (09) : 1369 - 1376
  • [49] SELECTIVE GROWTH OF WIRE STRUCTURES OF GAAS ON CAF2 USING FOCUSED ELECTRON-BEAMS
    KAWASAKI, K
    TSUTSUI, K
    FURUKAWA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (1B): : 914 - 918
  • [50] ALGORITHM FOR ELECTRON DEPTH-DOSE DISTRIBUTIONS IN MULTILAYER SLAB ABSORBERS.
    Tabata, Tatsuo
    Ito, Rinsuke
    1600, (20):