A MOSAIC CRYSTAL BACKSCATTERING MONOCHROMATOR FOR HIGH-RESOLUTION POWDER DIFFRACTION

被引:2
|
作者
WROBLEWSKI, T
TERNES, W
机构
[1] Hamburger Synchrotronstrahlungslabor (HASYLAB), Deutsches Elektronensynchrotron (DESY), 2000 Hamburg 52
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1143105
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The resolution function of a powder diffractometer at a synchrotron radiation source increases with increasing Bragg angle of the monochromator. Consequently, a monochromator close to backscattering has been designed and built. Two mosaic crystals of beryllium in nondispersive setting serve as optical elements. They are mounted on goniometer heads inside a tube-like housing which may be evacuated. Fine adjustment of one of the crystals is done with a micro-goniometer driven by a magnetostrictive actuator. The fact that the housing is a tube allows the use of the assembly as part of a multi-purpose monochromator system for powder diffraction.
引用
收藏
页码:1091 / 1093
页数:3
相关论文
共 50 条
  • [32] Disorder determined by high-resolution powder diffraction: structure of pentamethylcyclopentadienyllithium
    Dinnebier, RE
    Schneider, M
    van Smaalen, S
    Olbrich, F
    Behrens, U
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE, 1999, 55 : 35 - 44
  • [33] A REINVESTIGATION OF THE STRUCTURE OF TETRAHYDROFURAN BY HIGH-RESOLUTION NEUTRON POWDER DIFFRACTION
    DAVID, WIF
    IBBERSON, RM
    ACTA CRYSTALLOGRAPHICA SECTION C-CRYSTAL STRUCTURE COMMUNICATIONS, 1992, 48 : 301 - 303
  • [34] Disorder determined by high-resolution powder diffraction: Structure of pentamethylcyclopentadienyllithium
    Dinnebier, R.E.
    Schneider, M.
    Van Smaalen, S.
    Olbrich, F.
    Behrens, U.
    Acta Crystallographica, Section B: Structural Science, 1999, 55 (pt 1):
  • [35] ECHIDNA: a decade of high-resolution neutron powder diffraction at OPAL
    Avdeev, Maxim
    Hester, James R.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2018, 51 : 1597 - 1604
  • [36] A NOVEL BEAM-CONDITIONING MONOCHROMATOR FOR HIGH-RESOLUTION X-RAY-DIFFRACTION
    LOXLEY, N
    TANNER, BK
    BOWEN, DK
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1995, 28 (pt 3) : 314 - 317
  • [37] THE AB-INITIO CRYSTAL-STRUCTURE DETERMINATION OF PERDEUTERODIMETHYLACETYLENE BY HIGH-RESOLUTION NEUTRON POWDER DIFFRACTION
    IBBERSON, RM
    PRAGER, M
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE, 1995, 51 : 71 - 76
  • [38] Temperature-dependent crystal structure analysis of methyl iodide by high-resolution neutron powder diffraction
    Ibberson, Richard M.
    Prager, Michael
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 2007, 222 (08): : 416 - 419
  • [39] Crystal structure of propylthiouracil determined using high-resolution synchrotron X-ray powder diffraction
    Ferreira, Fabio Furlan
    Trindade, Antonio Carlos
    Antonio, Selma Gutierrez
    Paiva-Santos, Carlos de Oliveira
    CRYSTENGCOMM, 2011, 13 (17): : 5474 - 5479
  • [40] CAN A GRADIENT CRYSTAL COMPETE WITH A MOSAIC CRYSTAL AS A MONOCHROMATOR IN NEUTRON-DIFFRACTION OR X-RAY-DIFFRACTION
    LISS, KD
    MAGERL, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (01): : 90 - 98