The resolution function of a powder diffractometer at a synchrotron radiation source increases with increasing Bragg angle of the monochromator. Consequently, a monochromator close to backscattering has been designed and built. Two mosaic crystals of beryllium in nondispersive setting serve as optical elements. They are mounted on goniometer heads inside a tube-like housing which may be evacuated. Fine adjustment of one of the crystals is done with a micro-goniometer driven by a magnetostrictive actuator. The fact that the housing is a tube allows the use of the assembly as part of a multi-purpose monochromator system for powder diffraction.
引用
收藏
页码:1091 / 1093
页数:3
相关论文
共 50 条
  • [21] IMPROVED HIGH-RESOLUTION GRASSHOPPER MONOCHROMATOR
    BROWN, FC
    NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2): : 100 - 100
  • [22] A HIGH-RESOLUTION MONOCHROMATOR FOR UNDULATOR RADIATION
    BROWN, FC
    HULBERT, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 42 - 45
  • [23] Crystal structure of melaminium orthophosphate from high-resolution synchrotron powder-diffraction data
    De Ridder, DJA
    Goubitz, K
    Brodski, V
    Peschar, R
    Schenk, H
    HELVETICA CHIMICA ACTA, 2004, 87 (07) : 1894 - 1905
  • [24] THE CRYSTAL-STRUCTURE OF CBRF3 BY HIGH-RESOLUTION POWDER NEUTRON-DIFFRACTION
    JOUANNEAUX, A
    FITCH, AN
    COCKCROFT, JK
    MOLECULAR PHYSICS, 1992, 77 (01) : 45 - 50
  • [25] Disordered crystal structure of pentamethylcyclopentadienylsodium as seen by high-resolution X-ray powder diffraction
    Tedesco, C
    Dinnebier, RE
    Olbrich, F
    van Smaalen, S
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE, 2001, 57 (05): : 673 - 679
  • [26] Influence of defects in monochromator on curves of diffraction reflections of high-resolution two-crystal X-ray diffractometry
    Kyslovs'ky, YM
    Olikhovs'ky, SJ
    Molodkin, VB
    Len', YG
    Vladimirova, TP
    Reshetnyk, OV
    Dzyublenko, MI
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2004, 26 (09): : 1241 - 1254
  • [27] THERMAL BILAYER MONOCHROMATOR CRYSTAL FOR A HIGH-RESOLUTION MULTIWAVELENGTH ANOMALOUS DIFFRACTION BEAMLINE AT THE EUROPEAN SYNCHROTRON-RADIATION FACILITY
    FERRER, JL
    ROTH, M
    FANCHON, E
    POUPON, G
    SAINTLAGER, MC
    BERAR, JF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2089 - 2091
  • [28] HIGH-RESOLUTION POWDER DIFFRACTION STUDIES OF COPPER(II) OXIDE
    LANGFORD, JI
    LOUER, D
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1991, 24 : 149 - 155
  • [29] Cyclopentadienylcaesium by high-resolution X-ray powder diffraction
    Dinnebier, RE
    Olbrich, F
    Bendele, GM
    ACTA CRYSTALLOGRAPHICA SECTION C-CRYSTAL STRUCTURE COMMUNICATIONS, 1997, 53 : 699 - 701
  • [30] HIGH-RESOLUTION POWDER DIFFRACTION BY WHITE SOURCE TRANSMISSION MEASUREMENTS
    JOHNSON, RG
    BOWMAN, CD
    AIP CONFERENCE PROCEEDINGS, 1982, (89) : 53 - 55