Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes

被引:0
|
作者
Liangpin Li
Liyun Yuan
Kun Yang
Yanan Wu
Simayilijiang Alafati
Xia Hua
Yan Wang
Xiaoyong Yuan
机构
[1] Tianjin Medical University,Clinical College of Ophthalmology
[2] Tianjin Eye Institute,Tianjin Key Laboratory of Ophthalmology and Visual Science
[3] Nankai University,School of Medicine
[4] Tianjin University,Tianjin Aier Eye Hospital
关键词
D O I
暂无
中图分类号
学科分类号
摘要
As of 2021, over 2.8 million small-incision lenticule extraction (SMILE) procedures have been performed in China. However, knowledge regarding the selection of intraocular lens (IOL) power calculation formula for post-SMILE cataract patients remains limited. This study included 52 eyes of 26 myopic patients from northern China who underwent SMILE at Tianjin Eye Hospital from September 2022 to February 2023 to investigate the suitability of multiple IOL calculation formulas in post-SMILE patients using a theoretical surgical model. We compared the postoperative results obtained from three artificial intelligence (AI)-based formulas and six conventional formulas provided by the American Society of Cataract and Refractive Surgery (ASCRS). These formulas were applied to calculate IOL power using both total keratometry (TK) and keratometry (K) values, and the results were compared to the preoperative results obtained from the Barrett Universal II (BUII) formula for the SMILE patients. Among the evaluated formulas, the results obtained from the Emmetropia Verifying Optical 2.0 Formula with TK (EVO-TK) (0.40 ± 0.29 D, range 0–1.23 D), Barrett True K with K formula (BTK-K, 0.41 ± 0.26 D, range 0.01–1.19 D), and Masket with K formula (Masket-K, 0.44 ± 0.33 D, range 0.02–1.39 D) demonstrated the closest proximity to BUII. Notably, the highest proportion of prediction errors within 0.5 D was observed with the BTK-K (71.15%), EVO-TK (69.23%), and Masket-K (67.31%), with the BTK-K showing a significantly higher proportion than the Masket-K (p < 0.001). Our research indicates that in post-SMILE patients, the EVO-TK, BTK-K, and Masket-K may yield more accurate calculation results. At their current stage in development, AI-based formulas do not demonstrate significant advantages over conventional formulas. However, the application of historical data can enhance the performance of these formulas.
引用
收藏
相关论文
共 50 条
  • [41] Accuracy of intraocular lens power calculation formulae after laser refractive surgery in myopic eyes: a meta-analysis
    Li, Hongyu
    Nan, Li
    Li, Jun
    Song, Hui
    EYE AND VISION, 2020, 7 (01)
  • [42] Comparison of Different Intraocular Lens Power Calculation Formulas in Eyes With Primary Angle Closure
    Liu, Jinkun
    Wang, Yuhong
    Huang, Weiyi
    Wang, Fei
    Xu, Yazhang
    Xue, Yingying
    Zhao, Zhimin
    Huang, Luping
    Gao, Ruxin
    JOURNAL OF GLAUCOMA, 2024, 33 (09) : 665 - 670
  • [43] ACCURACY OF THE NEWER GENERATION INTRAOCULAR-LENS POWER CALCULATION FORMULAS IN LONG AND SHORT EYES
    OLSEN, T
    THIM, K
    CORYDON, L
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (02): : 187 - 193
  • [44] Analysis of Intraocular lens power calculation for eyes with previous myopic LASIK
    Jin, GJC
    Crandall, AS
    Jin, Y
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (04) : 387 - 395
  • [45] Intraocular lens power calculation for eyes with previous myopic LASIK - Reply
    Lin, George I. C.
    Crandall, Alan S.
    Jin, Yian
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : 847 - 848
  • [46] Intraocular lens power calculation and optimized constants for highly myopic eyes
    Petermeier, Katrin
    Gekeler, Florian
    Messias, Andre
    Spitzer, Martin S.
    Haigis, Wolfgang
    Szurman, Peter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1575 - 1581
  • [47] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [48] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [49] Accuracy of Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Holladay, Jack T.
    Chang, William J.
    OPHTHALMOLOGY, 2018, 125 (02) : 169 - 178
  • [50] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208