Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes

被引:0
|
作者
Liangpin Li
Liyun Yuan
Kun Yang
Yanan Wu
Simayilijiang Alafati
Xia Hua
Yan Wang
Xiaoyong Yuan
机构
[1] Tianjin Medical University,Clinical College of Ophthalmology
[2] Tianjin Eye Institute,Tianjin Key Laboratory of Ophthalmology and Visual Science
[3] Nankai University,School of Medicine
[4] Tianjin University,Tianjin Aier Eye Hospital
关键词
D O I
暂无
中图分类号
学科分类号
摘要
As of 2021, over 2.8 million small-incision lenticule extraction (SMILE) procedures have been performed in China. However, knowledge regarding the selection of intraocular lens (IOL) power calculation formula for post-SMILE cataract patients remains limited. This study included 52 eyes of 26 myopic patients from northern China who underwent SMILE at Tianjin Eye Hospital from September 2022 to February 2023 to investigate the suitability of multiple IOL calculation formulas in post-SMILE patients using a theoretical surgical model. We compared the postoperative results obtained from three artificial intelligence (AI)-based formulas and six conventional formulas provided by the American Society of Cataract and Refractive Surgery (ASCRS). These formulas were applied to calculate IOL power using both total keratometry (TK) and keratometry (K) values, and the results were compared to the preoperative results obtained from the Barrett Universal II (BUII) formula for the SMILE patients. Among the evaluated formulas, the results obtained from the Emmetropia Verifying Optical 2.0 Formula with TK (EVO-TK) (0.40 ± 0.29 D, range 0–1.23 D), Barrett True K with K formula (BTK-K, 0.41 ± 0.26 D, range 0.01–1.19 D), and Masket with K formula (Masket-K, 0.44 ± 0.33 D, range 0.02–1.39 D) demonstrated the closest proximity to BUII. Notably, the highest proportion of prediction errors within 0.5 D was observed with the BTK-K (71.15%), EVO-TK (69.23%), and Masket-K (67.31%), with the BTK-K showing a significantly higher proportion than the Masket-K (p < 0.001). Our research indicates that in post-SMILE patients, the EVO-TK, BTK-K, and Masket-K may yield more accurate calculation results. At their current stage in development, AI-based formulas do not demonstrate significant advantages over conventional formulas. However, the application of historical data can enhance the performance of these formulas.
引用
收藏
相关论文
共 50 条
  • [21] Intraocular lens power calculation formulas in Chinese eyes with high axial myopia
    Tsang, CSL
    Chong, GSL
    Yiu, EPF
    Ho, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1358 - 1364
  • [22] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Wei, Ling
    Cheng, Kaiwen
    He, Wenwen
    Zhu, Xiangjia
    Lu, Yi
    EYE AND VISION, 2022, 9 (01)
  • [23] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Ling Wei
    Kaiwen Cheng
    Wenwen He
    Xiangjia Zhu
    Yi Lu
    Eye and Vision, 9
  • [24] Accuracy of new intraocular lens calculation formulas in Chinese eyes with short axial lengths
    Ma, Yueting
    Lin, Yongdong
    Li, Yuancun
    Hu, Zhuoyi
    Qiu, Kunliang
    FRONTIERS IN MEDICINE, 2023, 10
  • [25] Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes
    Wang, Qiwei
    Jiang, Wu
    Lin, Tiao
    Wu, Xiaohang
    Lin, Haotian
    Chen, Weirong
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (04): : 356 - 363
  • [26] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial myopia
    Stopyra, Wiktor
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (02) : 225 - 230
  • [27] Accuracy of 20 Intraocular Lens Power Calculation Formulas in Medium-Long Eyes
    Stopyra, Wiktor
    Voytsekhivskyy, Oleksiy
    Grzybowski, Andrzej
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (07) : 1893 - 1907
  • [28] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial hyperopia
    Stopyra, Wiktor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [29] Accuracy of 12 Intraocular Lens Power Formulas After Corneal Myopic Refractive Surgery
    Rong, Xin
    Liu, Jiewei
    Jiang, Lin
    Wang, Xiaogang
    Feng, Tianfeng
    Lu, Zhenyang
    Fan, Zeqi
    Yan, Hua
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (06) : e354 - e361
  • [30] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988