Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes

被引:0
|
作者
Liangpin Li
Liyun Yuan
Kun Yang
Yanan Wu
Simayilijiang Alafati
Xia Hua
Yan Wang
Xiaoyong Yuan
机构
[1] Tianjin Medical University,Clinical College of Ophthalmology
[2] Tianjin Eye Institute,Tianjin Key Laboratory of Ophthalmology and Visual Science
[3] Nankai University,School of Medicine
[4] Tianjin University,Tianjin Aier Eye Hospital
关键词
D O I
暂无
中图分类号
学科分类号
摘要
As of 2021, over 2.8 million small-incision lenticule extraction (SMILE) procedures have been performed in China. However, knowledge regarding the selection of intraocular lens (IOL) power calculation formula for post-SMILE cataract patients remains limited. This study included 52 eyes of 26 myopic patients from northern China who underwent SMILE at Tianjin Eye Hospital from September 2022 to February 2023 to investigate the suitability of multiple IOL calculation formulas in post-SMILE patients using a theoretical surgical model. We compared the postoperative results obtained from three artificial intelligence (AI)-based formulas and six conventional formulas provided by the American Society of Cataract and Refractive Surgery (ASCRS). These formulas were applied to calculate IOL power using both total keratometry (TK) and keratometry (K) values, and the results were compared to the preoperative results obtained from the Barrett Universal II (BUII) formula for the SMILE patients. Among the evaluated formulas, the results obtained from the Emmetropia Verifying Optical 2.0 Formula with TK (EVO-TK) (0.40 ± 0.29 D, range 0–1.23 D), Barrett True K with K formula (BTK-K, 0.41 ± 0.26 D, range 0.01–1.19 D), and Masket with K formula (Masket-K, 0.44 ± 0.33 D, range 0.02–1.39 D) demonstrated the closest proximity to BUII. Notably, the highest proportion of prediction errors within 0.5 D was observed with the BTK-K (71.15%), EVO-TK (69.23%), and Masket-K (67.31%), with the BTK-K showing a significantly higher proportion than the Masket-K (p < 0.001). Our research indicates that in post-SMILE patients, the EVO-TK, BTK-K, and Masket-K may yield more accurate calculation results. At their current stage in development, AI-based formulas do not demonstrate significant advantages over conventional formulas. However, the application of historical data can enhance the performance of these formulas.
引用
收藏
相关论文
共 50 条
  • [11] Accuracy of Intraocular Lens Power Calculation Formulas in Myopic Eyes with Target Refractions of Emmetropia and Intentional Myopia
    Sakai, Daiki
    Hiranni, Yasuhiko
    Nakamura, Makoto
    Kurinnoto, Yasuo
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4535 - 4541
  • [12] The comparison of the intraocular lens power calculation formulas in long eyes
    Yildiz, Aydin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (07) : 1173 - 1176
  • [13] Comparison of 9 intraocular lens power calculation formulas
    Cooke, David L.
    Cooke, Timothy L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1157 - 1164
  • [14] Efficacy of corneal curvature on the accuracy of 8 intraocular lens power calculation formulas in 302 highly myopic eyes
    Mo, Er
    Feng, Ke
    Li, Qiyuan
    Xu, Jingyuan
    Cen, Jiaying
    Li, Jin
    Zhao, Yun-e
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (12): : 1195 - 1200
  • [15] Accuracy of Modified Axial Length Adjustment for Intraocular Lens Power Calculation in Chinese Axial Myopic Eyes
    Cheng, Huanhuan
    Liu, Liangping
    Sun, Ao
    Wu, Mingxing
    CURRENT EYE RESEARCH, 2020, 45 (07) : 827 - 833
  • [16] Comparison of the accuracy of 11 intraocular lens power calculation formulas
    Carmona-Gonzalez, David
    Castillo-Gomez, Alfredo
    Palomino-Bautista, Carlos
    Romero-Dominguez, Marta
    Gutierrez-Moreno, Maria Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2370 - 2376
  • [17] Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE
    Elotmani, Anouar Meziane
    Messerschmidt-Roth, Anke
    Nehme, Alexandra
    Mueller, Hans-Helge
    Sekundo, Walter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (05): : 467 - 473
  • [18] Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes
    Li, Xinxin
    Song, Chunyuan
    Wang, Yong
    Wang, Jing
    Tang, Qiongyan
    Wu, Zheming
    Zhou, Yanwen
    Sun, Juan
    Jia, Yanhong
    Lin, Zhenlin
    Li, Shaowei
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) : 3619 - 3628
  • [19] Comparison of 9 modern intraocular lens power calculation formulas for a quadrifocal intraocular lens
    Shajari, Mehdi
    Kolb, Carolin M.
    Petermann, Kerstin
    Boehm, Myriam
    Herzog, Michael
    de'Lorenzo, Nina
    Schoenbrunn, Sabrina
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08): : 942 - 948
  • [20] Comparison of six methods for the intraocular lens power calculation in high myopic eyes
    Ji, Jiali
    Liu, Yan
    Zhang, Jing
    Wu, Xinhua
    Shao, Wanyu
    Ma, Bo
    Luo, Min
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (01) : 96 - 102