Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes

被引:0
|
作者
Liangpin Li
Liyun Yuan
Kun Yang
Yanan Wu
Simayilijiang Alafati
Xia Hua
Yan Wang
Xiaoyong Yuan
机构
[1] Tianjin Medical University,Clinical College of Ophthalmology
[2] Tianjin Eye Institute,Tianjin Key Laboratory of Ophthalmology and Visual Science
[3] Nankai University,School of Medicine
[4] Tianjin University,Tianjin Aier Eye Hospital
关键词
D O I
暂无
中图分类号
学科分类号
摘要
As of 2021, over 2.8 million small-incision lenticule extraction (SMILE) procedures have been performed in China. However, knowledge regarding the selection of intraocular lens (IOL) power calculation formula for post-SMILE cataract patients remains limited. This study included 52 eyes of 26 myopic patients from northern China who underwent SMILE at Tianjin Eye Hospital from September 2022 to February 2023 to investigate the suitability of multiple IOL calculation formulas in post-SMILE patients using a theoretical surgical model. We compared the postoperative results obtained from three artificial intelligence (AI)-based formulas and six conventional formulas provided by the American Society of Cataract and Refractive Surgery (ASCRS). These formulas were applied to calculate IOL power using both total keratometry (TK) and keratometry (K) values, and the results were compared to the preoperative results obtained from the Barrett Universal II (BUII) formula for the SMILE patients. Among the evaluated formulas, the results obtained from the Emmetropia Verifying Optical 2.0 Formula with TK (EVO-TK) (0.40 ± 0.29 D, range 0–1.23 D), Barrett True K with K formula (BTK-K, 0.41 ± 0.26 D, range 0.01–1.19 D), and Masket with K formula (Masket-K, 0.44 ± 0.33 D, range 0.02–1.39 D) demonstrated the closest proximity to BUII. Notably, the highest proportion of prediction errors within 0.5 D was observed with the BTK-K (71.15%), EVO-TK (69.23%), and Masket-K (67.31%), with the BTK-K showing a significantly higher proportion than the Masket-K (p < 0.001). Our research indicates that in post-SMILE patients, the EVO-TK, BTK-K, and Masket-K may yield more accurate calculation results. At their current stage in development, AI-based formulas do not demonstrate significant advantages over conventional formulas. However, the application of historical data can enhance the performance of these formulas.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Li, Liangpin
    Yuan, Liyun
    Yang, Kun
    Wu, Yanan
    Alafati, Simayilijiang
    Hua, Xia
    Wang, Yan
    Yuan, Xiaoyong
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [2] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [3] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [5] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Jia-Qing
    Zou, Xu-Yuan
    Zheng, Dan-Ying
    Chen, Wei-Rong
    Sun, Ao
    Luo, Li-Xia
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 943 - 948
  • [6] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Jia-Qing Zhang
    Xu-Yuan Zou
    Dan-Ying Zheng
    Wei-Rong Chen
    Ao Sun
    Li-Xia Luo
    International Journal of Ophthalmology, 2019, (06) : 943 - 948
  • [7] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [8] Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia
    Liu, Jiewei
    Wang, Li
    Chai, Feiyan
    Han, Yu
    Qian, Suqin
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 725 - 731
  • [9] Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes
    Zhu, Wei
    Zhang, Feng-Ju
    Li, Yu
    Song, Yan-Zheng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (04) : 560 - +
  • [10] Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes
    Wei Zhu
    Feng-Ju Zhang
    Yu Li
    Yan-Zheng Song
    International Journal of Ophthalmology, 2020, 13 (04) : 560 - 566