Conductive glucose sensor using glucose oxidase immobilized macro porous silicon has been studied in this paper. Macro porous silicon layer is grown on p-type silicon substrate by electrochemical etching process. Two electrodes have been made with silver on front side of the macro porous silicon layer. Then the macro porous silicon surface has been functionalized for efficient glucose sensing by physisorption of glucose oxidase. Current–voltage characteristics have been studied at different glucose concentrations. Current value initially increases due to adsorption of glucose molecules upto 1 mM glucose concentration, after that current value decreases with increasing glucose concentration. Sensor response has been analysed with the help of different types of conduction mechanisms like hopping, Poole–Frenkel, trap-assisted and Fowler–Nordheim tunneling. Different conduction mechanisms are dominating at different applied field ranges. The sensor shows good response, high sensitivity and excellent repetitive behavior.
引用
收藏
相关论文
共 50 条
  • [21] Glucose biosensing based on a hydrogel optical fiber immobilized with glucose oxidase
    Bian Zhenglan
    Qi Yue
    Xue Liang
    Hu Anduo
    Yang Hui
    Chu Fenghong
    OPTIK, 2022, 255
  • [22] AMPEROMETRIC GLUCOSE SENSORS BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN NAFION
    RISHPON, J
    GOTTESFELD, S
    CAMPBELL, C
    DAVEY, J
    ZAWODZINSKI, TA
    ELECTROANALYSIS, 1994, 6 (01) : 17 - 21
  • [23] STUDIES ON THE CATALYTIC LIFETIME OF IMMOBILIZED GLUCOSE-OXIDASE FOR A POTENTIALLY IMPLANTABLE GLUCOSE SENSOR
    GOUGH, DA
    LEYPOLDT, JK
    ARMOUR, JC
    ANDERMAN, J
    FEDERATION PROCEEDINGS, 1981, 40 (03) : 467 - 467
  • [24] Novel optical solid-state glucose sensor using immobilized glucose oxidase
    White, BJ
    Harmon, HJ
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2002, 296 (05) : 1069 - 1071
  • [25] CHARACTERISTICS OF GLUCOSE SENSOR WITH IMMOBILIZED GLUCOSE-OXIDASE SUPPORTED BY RECONSTITUTED COLLAGEN MEMBRANE
    MORISHITA, M
    OSAKI, T
    GONDO, S
    KAGAKU KOGAKU RONBUNSHU, 1981, 7 (03) : 320 - 323
  • [26] INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM
    CENTONZE, D
    GUERRIERI, A
    MALITESTA, C
    PALMISANO, F
    ZAMBONIN, PG
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09): : 729 - 733
  • [27] GLUCOSE-OXIDASE IMMOBILIZED POLYETHYLENE-G-ACRYLIC ACID MEMBRANE FOR GLUCOSE-OXIDASE SENSOR
    HSIUE, GH
    WANG, CC
    BIOTECHNOLOGY AND BIOENGINEERING, 1990, 36 (08) : 811 - 815
  • [28] IMPROVED ENZYME SENSOR FOR GLUCOSE WITH AN ULTRA-FILTRATION MEMBRANE AND IMMOBILIZED GLUCOSE-OXIDASE
    KOYAMA, M
    SATO, Y
    AIZAWA, M
    SUZUKI, S
    ANALYTICA CHIMICA ACTA, 1980, 116 (02) : 307 - 314
  • [29] DETERMINATION OF GLUCOSE IN ENZYMATIC ANALYZER BASED ON MINIREACTORS WITH IMMOBILIZED GLUCOSE-OXIDASE
    KOVALENKO, GA
    SOKOLOVSKII, VD
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1989, 44 (07): : 1082 - 1086
  • [30] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zaide Zhou
    Lina Qiao
    Peng Zhang
    Dan Xiao
    Martin M. F. Choi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 673 - 679