Glucose oxidase immobilized macro porous silicon based conductive glucose sensor

被引:0
|
作者
Tanusree Sarkar
Nandini Mukherjee
Jayoti Das
机构
[1] Jadavpur University,Department of Computer Science and Engineering
[2] Jadavpur University,Department of Physics
来源
Applied Physics A | 2022年 / 128卷
关键词
Biosensor; Conductivity measurement; Glucose oxidase; Glucose sensor; Macro porous silicon;
D O I
暂无
中图分类号
学科分类号
摘要
Conductive glucose sensor using glucose oxidase immobilized macro porous silicon has been studied in this paper. Macro porous silicon layer is grown on p-type silicon substrate by electrochemical etching process. Two electrodes have been made with silver on front side of the macro porous silicon layer. Then the macro porous silicon surface has been functionalized for efficient glucose sensing by physisorption of glucose oxidase. Current–voltage characteristics have been studied at different glucose concentrations. Current value initially increases due to adsorption of glucose molecules upto 1 mM glucose concentration, after that current value decreases with increasing glucose concentration. Sensor response has been analysed with the help of different types of conduction mechanisms like hopping, Poole–Frenkel, trap-assisted and Fowler–Nordheim tunneling. Different conduction mechanisms are dominating at different applied field ranges. The sensor shows good response, high sensitivity and excellent repetitive behavior.
引用
收藏
相关论文
共 50 条
  • [41] A METHOD FOR MEASURING GLUCOSE OXIDASE-IMMOBILIZED GLUCOSE
    IVANOV, IP
    DANEV, SI
    DIMITROV, DG
    LABORATORNOE DELO, 1991, (10): : 28 - 30
  • [42] IMMOBILIZED GLUCOSE OXIDASE USED TO MEASURE GLUCOSE IN SERUM
    KUNZ, HJ
    STASTNY, M
    CLINICAL CHEMISTRY, 1974, 20 (08) : 1018 - 1022
  • [43] An Enzyme-Chemically Modified Carbon Paste Electrode as a Glucose Sensor Based on Glucose Oxidase Immobilized in a Polyaniline Film
    Shengshui Hu
    Jun Luo
    Dafu Cui
    Analytical Sciences, 1999, 15 : 585 - 588
  • [44] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [45] Catalytic effects of magnetic and conductive nanoparticles on immobilized glucose oxidase in skin sensors
    Alarcon-Segovia, Lilian C.
    Bandodkar, Amay J.
    Rogers, John A.
    Rintoul, Ignacio
    NANOTECHNOLOGY, 2021, 32 (37)
  • [46] Mechanical control of the activity of glucose oxidase immobilized on porous polyvinylchloride membrane
    Ishimori, Yoshio
    Karube, Isao
    Suzuki, Shuichi
    1600, John Wiley and Sons Inc (23):
  • [47] A glucose oxidase immobilized electrode based on modified graphite
    Dimcheva, N
    Horozova, E
    Jordanova, Z
    ZEITSCHRIFT FUR NATURFORSCHUNG C-A JOURNAL OF BIOSCIENCES, 2002, 57 (7-8): : 705 - 711
  • [48] Silicon-Based Glucose Oxidase Working Electrode for Glucose Sensing
    Soto, Jacqueline
    Hughes, Tyler
    Li, Yize Stephanie
    ACS OMEGA, 2019, 4 (19): : 18312 - 18316
  • [49] Functionalization of nanostructured porous silicon microcavities for glucose oxidase detection
    Palestino, Gabriela
    Legros, Rene
    Agarwal, Vivechana
    Perez, Elias
    Gergely, Csilla
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) : 27 - 34
  • [50] Optical characterization of porous silicon microcavities for glucose oxidase biosensing
    Palestino, G.
    Agarwal, V.
    Garcia, D. B.
    Legros, R.
    Perez, E.
    Gergely, C.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE, 2008, 6991