An empirical expression for the full energy peak efficiency of an N-type high purity germanium detector

被引:0
|
作者
E. K. Osae
B. J. B. Nyarko
Y. Serfor-Armah
E. O. Darko
机构
[1] Ghana Atomic Energy Commission,Neutron Activation Analysis Laboratory, National Nuclear Research Institute
[2] Ghana Atomic Energy Commission,Radiation Protection Board
来源
Journal of Radioanalytical and Nuclear Chemistry | 1999年 / 242卷
关键词
Standard Deviation; Physical Chemistry; Inorganic Chemistry; Radionuclide; Energy Range;
D O I
暂无
中图分类号
学科分类号
摘要
An empirical expression for the full energy peak efficiency (ε) in terms of the gamma-ray energy (E) and the vertical distance from the detector surface (z) (i.e.,ε=ε(z,E)) has been obtained for an N-type high purity germanium (HPGE) detector using an extended mixed standard radionuclide solution. Comparison of the calculated efficiencies and the experimentally measured values for the energy range of 59.5–1332.5 keV and a source-to-detector distance of 1.2–7.2 cm showed that the theoretical values agree with that of the experiment within 1.5–3.7% standard deviations. This shows a good agreement between the theory and the experiment.
引用
收藏
页码:617 / 622
页数:5
相关论文
共 50 条
  • [31] High Thermoelectric Efficiency of n-type PbS
    Wang, Heng
    Schechtel, Eugen
    Pei, Yanzhong
    Snyder, G. Jeffrey
    ADVANCED ENERGY MATERIALS, 2013, 3 (04) : 488 - 495
  • [32] ANISOTROPY OF HIGH-FIELD CONDUCTIVITY IN N-TYPE GERMANIUM
    HAMMAR, C
    PHYSICAL REVIEW B-SOLID STATE, 1971, 4 (02): : 417 - &
  • [33] ANISOTROPY OF CONDUCTIVITY OF N-TYPE GERMANIUM AT HIGH ELECTRIC FIELDS
    DIENYS, V
    POZHELA, J
    PHYSICA STATUS SOLIDI, 1966, 17 (02): : 769 - &
  • [34] GALVANOMAGNETIC EFFECTS OF N-TYPE GERMANIUM IN HIGH ELECTRIC FIELDS
    KRIECHBA.M
    HEINRICH, H
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (03): : 303 - &
  • [36] ANISOTROPY OF CONDUCTIVITY OF N-TYPE GERMANIUM AT HIGH ELECTRIC FIELDS
    NATHAN, MI
    PHYSICAL REVIEW, 1963, 130 (06): : 2201 - &
  • [37] HIGH-FIELD SURFACE CONDUCTANCE OF N-TYPE GERMANIUM
    NAG, BR
    PARIA, H
    BRITISH JOURNAL OF APPLIED PHYSICS, 1966, 17 (01): : 71 - &
  • [38] High-precision efficiency calibration of a high-purity co-axial germanium detector
    Blank, B.
    Souin, J.
    Ascher, P.
    Audirac, L.
    Canchel, G.
    Gerbaux, M.
    Grevy, S.
    Giovinazzo, J.
    Guerin, H.
    Nieto, T. Kurtukian
    Matea, I.
    Bouzomita, H.
    Delahaye, P.
    Grinyer, G. F.
    Thomas, J. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 776 : 34 - 44
  • [39] Deep defects in n-type high-purity germanium: quantification of optical variants of deep level transient spectroscopy
    Blondeel, A
    Clauws, P
    PHYSICA B-CONDENSED MATTER, 1999, 273-4 : 584 - 588
  • [40] ANISOTROPY OF CONDUCTIVITY IN RANTE OF WARM ELECTRONS FOR HIGH-DOPED N-TYPE GERMANIUM AND N-TYPE SILICON
    TSCHULENA, GR