The choice of an autocorrelation length in dark-field lung imaging

被引:0
|
作者
Simon Spindler
Dominik Etter
Michał Rawlik
Maxim Polikarpov
Lucia Romano
Zhitian Shi
Konstantins Jefimovs
Zhentian Wang
Marco Stampanoni
机构
[1] Swiss Light Source,Department of Engineering Physics
[2] Paul Scherrer Institute,Key Laboratory of Particle & Radiation Imaging
[3] Institute for Biomedical Engineering,undefined
[4] ETH Zürich,undefined
[5] Tsinghua University,undefined
[6] (Tsinghua University) Ministry of Education,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Respiratory diseases are one of the most common causes of death, and their early detection is crucial for prompt treatment. X-ray dark-field radiography (XDFR) is a promising tool to image objects with unresolved micro-structures such as lungs. Using Talbot-Lau XDFR, we imaged inflated porcine lungs together with Polymethylmethacrylat (PMMA) microspheres (in air) of diameter sizes between 20 and 500 μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {m}$$\end{document} over an autocorrelation range of 0.8–5.2 μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {m}$$\end{document}. The results indicate that the dark-field extinction coefficient of porcine lungs is similar to that of densely-packed PMMA spheres with diameter of 200μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${200}\,\upmu \hbox {m}$$\end{document}, which is approximately the mean alveolar structure size. We evaluated that, in our case, the autocorrelation length would have to be limited to 0.57μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${0.57}\,\upmu \hbox {m}$$\end{document} in order to image 20cm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${20}\,\hbox {cm}$$\end{document}-thick lung tissue without critical visibility reduction (signal saturation). We identify the autocorrelation length to be the critical parameter of an interferometer that allows to avoid signal saturation in clinical lung dark-field imaging.
引用
收藏
相关论文
共 50 条
  • [21] Dark-field microscopy in imaging of plasmon resonant nanoparticles
    Liu, Mengmeng
    Chao, Jie
    Deng, Suhui
    Wang, Kun
    Li, Kun
    Fan, Chunhai
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 124 : 111 - 117
  • [22] COMPUTER EXPERIMENTS FOR TILTED BEAM DARK-FIELD IMAGING
    KRAKOW, W
    ULTRAMICROSCOPY, 1976, 1 (03) : 203 - 221
  • [23] Grating-Based Dark-field Breast Imaging
    Rieger, Jens
    Bayer, Florian
    Durst, Juergen
    Goedel, Karl
    Haas, Wilhelm
    Horn, Florian
    Michel, Thilo
    Pelzer, Georg
    Ritter, Andre
    Weber, Thomas
    Zang, Andrea
    Anton, Gisela
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [24] Dark-field Z-scan imaging technique
    Wang, Hongzhen
    Cassagne, Christophe
    Leblond, Herve
    Boudebs, Georges
    OPTICS COMMUNICATIONS, 2016, 366 : 148 - 153
  • [25] Computational and dark-field ghost imaging with ultraviolet light
    JIAQI SONG
    BAOLEI LIU
    YAO WANG
    CHAOHAO CHEN
    XUCHEN SHAN
    XIAOLAN ZHONG
    LING-AN WU
    FAN WANG
    Photonics Research, 2024, 12 (02) : 226 - 234
  • [26] X-ray dark-field imaging modeling
    Cong, W.
    Pfeiffer, F.
    Bech, M.
    Wang, G.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (06) : 908 - 912
  • [27] Optimization of x-ray dark-field CT for human-scale lung imaging
    Guo, Peiyuan
    Spindler, Simon
    Rawlik, Michal
    Lu, Jincheng
    Men, Longchao
    Hong, Mingzhi
    Stampanoni, Marco
    Yin, Hongxia
    Xu, Yan
    Wang, Zhenchang
    Zhang, Li
    Wang, Zhentian
    MEDICAL PHYSICS, 2025,
  • [28] EXPERIMENTAL INVESTIGATIONS OF BRIGHT-FIELD AND DARK-FIELD STEM IMAGING
    YAMADA, N
    HIRONO, K
    HIBINO, M
    MARUSE, S
    JOURNAL OF ELECTRON MICROSCOPY, 1984, 33 (03): : 285 - 285
  • [29] DARK-FIELD ILLUMINATION
    ABRAMOWITZ, MJ
    AMERICAN LABORATORY, 1991, 23 (17) : 60 - 61
  • [30] Dark-field competition
    Baumbach, Christoph
    PHYSICS WORLD, 2014, 27 (04) : 22 - 22