Voltammetric study of the hydrolysis product of fenthion at the Nafion®-modified glassy carbon electrode

被引:0
|
作者
G. Erdoğdu
机构
[1] Inönü University,Department of Chemistry, Faculty of Arts & Sciences
来源
关键词
Glassy Carbon Electrode; Hydrolysis Product; Differential Pulse; Diazinon; VOLTAMMETRIC Study;
D O I
暂无
中图分类号
学科分类号
摘要
The differential pulse voltammetric (DPV) method is proposed for the determination of phosphorothioate insecticide (fenthion) based on the oxidation of its hydrolysis product. A single peak at +0.65 V (vs. Ag/AgCl) is observed at the Nafion®-modified glassy carbon electrode in 0.1 M Britton-Robinson buffer solution (pH 4.0) as a supporting electrolyte. The voltammetric behavior of fenthion was investigated over a wide range of pH (2.0–8.0). The effect of the solution and operational parameters on the sensitivity of the DPV peak was carefully examined in order to select the optimum conditions for the determination of fenthion. Under optimum conditions, the oxidation response gives a linear calibration plot over a concentration range of 8.41 × 10−7−5.98 × 10−6 M and the detection limit is found to be 7.6 × 10−7 M. The effects of some diverse metal ions, anions, and some other organic molecules on the determination of fenthion were studied. The applicability of DPV for the determination of fenthion insecticide in a commercial sample as well as in some water samples was demonstrated.
引用
收藏
页码:466 / 469
页数:3
相关论文
共 50 条
  • [41] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [42] Nafion-modified glassy carbon electrode for trace determination of indium
    Xiang, CL
    Zou, YJ
    Xie, JJ
    Fei, XM
    Li, JH
    ANALYTICAL LETTERS, 2005, 38 (13) : 2045 - 2055
  • [43] Poly (alizarin) Modified Glassy Carbon Electrode for the Electrochemical Investigation of Omeprazole: A Voltammetric Study
    Mahanthesha, Kurangalara R.
    Swamy, Bahaddurghatta E. Kumara
    Pai, Karkala Vasantakumar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (02): : 234 - 244
  • [44] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    Baranowska, I.
    Bijak, K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) : 891 - 895
  • [46] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [47] Comparative Study on Electroanalysis of Fenthion Using Silver Amalgam Film Electrode and Glassy Carbon Electrode Modified with Reduced Graphene Oxide
    Smarzewska, Sylwia
    Metelka, Radovan
    Festinger, Natalia
    Guziejewski, Dariusz
    Ciesielski, Witold
    ELECTROANALYSIS, 2017, 29 (04) : 1154 - 1160
  • [48] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [49] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519
  • [50] Voltammetric Determination of Epinephrine using a Thiourea Modified Glassy Carbon Electrode
    Yazdely, Malihe Ahmadian
    Taher, Mohammad Ali
    Tajik, Somayeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (04): : 517 - 527