Nafion-modified glassy carbon electrode for trace determination of indium

被引:8
|
作者
Xiang, CL
Zou, YJ
Xie, JJ
Fei, XM [1 ]
Li, JH
机构
[1] Cent China Normal Univ, Dept Chem, Wuhan 430079, Peoples R China
[2] Wuhan Univ Technol, Dept Mat, Wuhan 430070, Peoples R China
关键词
undium; Nafion-modified electrode; adsorption stripping voltammetry;
D O I
10.1080/00032710500259425
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for determination of trace indium is proposed by the adsorption stripping voltammetry (ASV) using a Nafion-modified glassy carbon electrode (NMGCE). This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed, and the anodic peak potential is ca. -0.548 V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of indium in water samples. There is a good linear relationship between the peak current (i(p)) and indium(III) concentration in the range of 1.0x10(-9) -1.0x10(-7) mol/l, and the limit of detection is 7.5x10(-10) mol/l.
引用
收藏
页码:2045 / 2055
页数:11
相关论文
共 50 条
  • [1] Voltammetric behavior and determination of estrogens at Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromide
    Hu, SS
    Wu, KB
    Yi, HC
    Cui, DF
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 209 - 216
  • [2] Determination of Patent Blue V (E131) at a Nafion-modified glassy carbon electrode
    Desimoni, E
    Brunetti, B
    Cosio, MS
    ELECTROANALYSIS, 2006, 18 (03) : 231 - 235
  • [3] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [4] Adsorption stripping voltammetry of phenol at Nafion-modified glassy carbon electrode in the presence of surfactants
    Yi, HC
    Wu, KB
    Hu, SS
    Cui, DF
    TALANTA, 2001, 55 (06) : 1205 - 1210
  • [5] TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide
    de Oliveira, Rafael Henrique
    Goncalves, Daniel A.
    dos Reis, Diogo Duarte
    SENSORS, 2023, 23 (18)
  • [6] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Vu Thi Huong
    Toshinori Shimanouchi
    Do Phuc Quan
    Hiroshi Umakoshi
    Pham Hung Viet
    Ryoichi Kuboi
    Journal of Applied Electrochemistry, 2009, 39 : 2035 - 2042
  • [7] Electrochemical sensor for formaldehyde based on Pt–Pd nanoparticles and a Nafion-modified glassy carbon electrode
    Zhong-Liang Zhou
    Tian-Fang Kang
    Yan Zhang
    Shui-Yuan Cheng
    Microchimica Acta, 2009, 164 : 133 - 138
  • [8] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Huong, Vu Thi
    Shimanouchi, Toshinori
    Quan, Do Phuc
    Umakoshi, Hiroshi
    Viet, Pham Hung
    Kuboi, Ryoichi
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (10) : 2035 - 2042
  • [9] DETERMINATION OF ADENINE BY CHRONOPOTENTIOMETRIC STRIPPING ANALYSIS WITH NAFION-MODIFIED ELECTRODE
    JIN, LT
    LIU, SH
    BAI, ZP
    FANG, YZ
    ELECTROANALYSIS, 1993, 5 (07) : 611 - 614
  • [10] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015