Nafion-modified glassy carbon electrode for trace determination of indium

被引:8
|
作者
Xiang, CL
Zou, YJ
Xie, JJ
Fei, XM [1 ]
Li, JH
机构
[1] Cent China Normal Univ, Dept Chem, Wuhan 430079, Peoples R China
[2] Wuhan Univ Technol, Dept Mat, Wuhan 430070, Peoples R China
关键词
undium; Nafion-modified electrode; adsorption stripping voltammetry;
D O I
10.1080/00032710500259425
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for determination of trace indium is proposed by the adsorption stripping voltammetry (ASV) using a Nafion-modified glassy carbon electrode (NMGCE). This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed, and the anodic peak potential is ca. -0.548 V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of indium in water samples. There is a good linear relationship between the peak current (i(p)) and indium(III) concentration in the range of 1.0x10(-9) -1.0x10(-7) mol/l, and the limit of detection is 7.5x10(-10) mol/l.
引用
收藏
页码:2045 / 2055
页数:11
相关论文
共 50 条
  • [21] Determination of Copper(II) ion with a nafion-ethylenediamine modified glassy carbon electrode
    Ko, Young Chun
    Kim, Hee Cheol
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2007, 20 (03): : 213 - 218
  • [22] Determination of diquat at a Nafion film modified glassy carbon electrode using electrocatalytic voltammetry
    Lu, TW
    Sun, IW
    ELECTROANALYSIS, 2000, 12 (08) : 605 - 609
  • [23] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [24] An amperometric immunosensor based on Nafion-modified electrode for the determination of Schistosoma japonicum antibody
    Zhou, YM
    Wu, ZY
    Shen, GL
    Yu, RQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03) : 292 - 298
  • [25] SELECTIVE DETERMINATION OF OXALATE WITH A RUTHENIUM(II) COMPLEX NAFION-MODIFIED ELECTRODE COMBINED WITH A CARBON-DIOXIDE SENSOR
    EGASHIRA, N
    KUMASAKO, H
    KURAUCHI, Y
    OHGA, K
    ANALYTICAL SCIENCES, 1994, 10 (03) : 405 - 408
  • [26] Differential-pulse voltammetric determination of clenbuterol in bovine urine using a nafion-modified carbon paste electrode
    Moane, S
    Smyth, MR
    OKeeffe, M
    ANALYST, 1996, 121 (06) : 779 - 784
  • [27] Use of a Nafion-modified electrode for the voltammetric determination and speciation of lead in human whole blood
    Ibanez, JCV
    Lorente, MMF
    Suarez, JRC
    QUIMICA ANALITICA, 1998, 17 (02): : 95 - 103
  • [28] Determination of caffeine at a Nafion-covered glassy carbon electrode
    Brunetti, Barbara
    Desimoni, Elio
    Casati, Paolo
    ELECTROANALYSIS, 2007, 19 (2-3) : 385 - 388
  • [29] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [30] Highly sensitive determination of epinephrine by a MnO2/Nafion modified glassy carbon electrode
    Liu, Xiaojuan
    Ye, Daixin
    Luo, Liqiang
    Ding, Yaping
    Wang, Yulong
    Chu, Yuliang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 665 : 1 - 5