Voltammetric study of the hydrolysis product of fenthion at the Nafion®-modified glassy carbon electrode

被引:0
|
作者
G. Erdoğdu
机构
[1] Inönü University,Department of Chemistry, Faculty of Arts & Sciences
来源
关键词
Glassy Carbon Electrode; Hydrolysis Product; Differential Pulse; Diazinon; VOLTAMMETRIC Study;
D O I
暂无
中图分类号
学科分类号
摘要
The differential pulse voltammetric (DPV) method is proposed for the determination of phosphorothioate insecticide (fenthion) based on the oxidation of its hydrolysis product. A single peak at +0.65 V (vs. Ag/AgCl) is observed at the Nafion®-modified glassy carbon electrode in 0.1 M Britton-Robinson buffer solution (pH 4.0) as a supporting electrolyte. The voltammetric behavior of fenthion was investigated over a wide range of pH (2.0–8.0). The effect of the solution and operational parameters on the sensitivity of the DPV peak was carefully examined in order to select the optimum conditions for the determination of fenthion. Under optimum conditions, the oxidation response gives a linear calibration plot over a concentration range of 8.41 × 10−7−5.98 × 10−6 M and the detection limit is found to be 7.6 × 10−7 M. The effects of some diverse metal ions, anions, and some other organic molecules on the determination of fenthion were studied. The applicability of DPV for the determination of fenthion insecticide in a commercial sample as well as in some water samples was demonstrated.
引用
收藏
页码:466 / 469
页数:3
相关论文
共 50 条
  • [31] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Suling Yang
    Ran Yang
    Gang Li
    Jianjun Li
    Lingbo Qu
    Journal of Chemical Sciences, 2010, 122 : 919 - 926
  • [32] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Yang, Suling
    Yang, Ran
    Li, Gang
    Li, Jianjun
    Qu, Lingbo
    JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (06) : 919 - 926
  • [33] VOLTAMMETRIC DETERMINATION OF METHYLPARABAN IN COSMETICS USING A MULTI-WALL CARBON NANOTUBES/NAFION COMPOSITE MODIFIED GLASSY CARBON ELECTRODE
    Luo, Peili
    Liu, Jie
    Li, Yamin
    Miao, Yurui
    Ye, Baoxian
    ANALYTICAL LETTERS, 2012, 45 (16) : 2445 - 2454
  • [34] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [35] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [36] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [37] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [38] Simultaneous voltammetric determination of paracetamol and domperidone based on a graphene/platinum nanoparticles/nafion composite modified glassy carbon electrode
    Kalambate, Pramod K.
    Sanghavi, Bankim J.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 285 - 294
  • [39] Differential Pulse Voltammetric Determination of Fenobucarb at the Glassy Carbon Electrode, After Its Alkaline Hydrolysis to a Phenolic Product
    Department of Analytical Chemistry, University of Extremadura, E-06071, Badajoz, Spain
    不详
    Electroanalysis, 12 (952-955):
  • [40] Differential pulse voltammetric determination of fenobucarb at the glassy carbon electrode, after its alkaline hydrolysis to a phenolic product
    Cabanillas, AG
    Diaz, TG
    Salinas, F
    Ortiz, JM
    Kauffmann, JM
    ELECTROANALYSIS, 1997, 9 (12) : 952 - 955