The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm

被引:0
|
作者
Chul Hwan Park
Joohee Lee
Chisuk Oh
Kyung Hwa Han
Tae Hoon Kim
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital
[2] Yonsei University College of Medicine,Department of Radiology, Research Institute of Radiological Science, Severance Hospital
关键词
Multidetector computed tomography; Iterative model reconstruction; Low tube voltage; Prospective ECG gating; Coronary artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
We evaluated the feasibility of sub-millisievert (mSv) coronary CT angiography (CCTA) using low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm. Twenty-four non-obese healthy subjects (M:F 13:11; mean age 50.2 ± 7.8 years) were enrolled. Three sets of CT images were reconstructed using three different reconstruction methods: filtered back projection (FBP), iterative reconstruction (IR), and knowledge-based iterative model reconstruction (IMR). The scanning parameters were as follows: step-and-shoot axial scanning, 80 kVp, and 200 mAs. On the three sets of CT images, the attenuation and image noise values were measured at the aortic root. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated at the proximal right coronary artery and the left main coronary artery. The qualitative image quality of the CCTA with IMR was assessed using a 4-point grading scale (grade 1, poor; grade 4, excellent). The mean radiation dose of the CCTA was 0.89 ± 0.09 mSv. The attenuation values with IMR were not different from those of other reconstruction methods. The image noise with IMR was significantly lower than with IR and FBP. Compared to FBP, the noise reduction rate of IMR was 69 %. The SNR and CNR of CCTA with IMR were significantly higher than with FBP or IR. On the qualitative analysis with IMR, all included segments were diagnostic (grades 2, 3, and 4), and the mean image quality score was 3.6 ± 0.6. In conclusion, CCTA with low tube voltage, prospective ECG gating, and an IMR algorithm might be a feasible method that allows for sub-millisievert radiation doses and good image quality when used with non-obese subjects.
引用
收藏
页码:197 / 203
页数:6
相关论文
共 50 条
  • [41] Contrast-Enhanced CT with Knowledge-Based Iterative Model Reconstruction for the Evaluation of Parotid Gland Tumors: A Feasibility Study
    Park, Chae Jung
    Kim, Ki Wook
    Lee, Ho-Joon
    Kim, Myeong-Jin
    Kim, Jinna
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (05) : 957 - 964
  • [42] Impact of Knowledge-Based Iterative Model Reconstruction on Image Quality and Hemodynamic Parameters in Dynamic Myocardial Computed Tomography Perfusion Using Low-Tube-Voltage Scan: A Feasibility Study
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Kouchi, Takanori
    Hosokawa, Takaaki
    Nishiyama, Hikaru
    Kawaguchi, Naoto
    Kido, Tomoyuki
    Uetani, Teruyoshi
    Mochizuki, Teruhito
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (05) : 811 - 816
  • [43] Non-inferior low-dose coronary computed tomography angiography image quality with knowledge-based iterative model reconstruction for overweight patients
    Park, In Kyung
    Park, Jeffrey
    Kim, Tae Hoon
    Lee, Joohee
    Han, Kyunghwa
    Oh, Chisuk
    Park, Chul Hwan
    PLOS ONE, 2018, 13 (12):
  • [44] CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction
    Joonho Hur
    Sung Bin Park
    Jong Beum Lee
    Hyun Jeong Park
    In Ho Chang
    Jong Kyou Kwon
    Yang Soo Kim
    Abdominal Imaging, 2015, 40 : 2432 - 2440
  • [45] CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction
    Hur, Joonho
    Park, Sung Bin
    Lee, Jong Beum
    Park, Hyun Jeong
    Chang, In Ho
    Kwon, Jong Kyou
    Kim, Yang Soo
    ABDOMINAL IMAGING, 2015, 40 (07): : 2432 - 2440
  • [46] CT FOR EVALUATION OF UROLITHIASIS: IMAGE QUALITY OF ULTRALOW-DOSE (SUB MSV) CT WITH KNOWLEDGE-BASED ITERATIVE RECONSTRUCTION AND DIAGNOSTIC PERFORMANCE OF LOW-DOSE CT WITH STATISTICAL ITERATIVE RECONSTRUCTION
    Kim, Jin Wook
    Moon, Young Tae
    Kim, Kyung Do
    Kim, Tae-Hyoung
    Myung, Soon Chul
    Ahn, Seung Hyun
    Choi, Jae Duck
    Kim, Jung Hoon
    Kim, Min Soo
    Lee, Shin Young
    Chi, Byung Hoon
    Chang, In Ho
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1079 - E1079
  • [47] The Feasibility of Deep Learning-Based Reconstruction for Low-Tube-Voltage CT Angiography for Transcatheter Aortic Valve Implantation
    Kojima, Tsukasa
    Yamasaki, Yuzo
    Matsuura, Yuko
    Mikayama, Ryoji
    Shirasaka, Takashi
    Kondo, Masatoshi
    Kamitani, Takeshi
    Kato, Toyoyuki
    Ishigami, Kousei
    Yabuuchi, Hidetake
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (01) : 77 - 84
  • [48] Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study
    Zheng, Minwen
    Liu, Ying
    Wei, Mengqi
    Wu, Yongjie
    Zhao, Hongliang
    Li, Jian
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : E92 - E99
  • [49] Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
    Yuan, Dian
    Wang, Luotong
    Lyu, Peijie
    Zhang, Yonggao
    Gao, Jianbo
    Liu, Jie
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (06): : 1377 - 1388
  • [50] Increasing iterative reconstruction strength at low tube voltage in coronary CT angiography protocols using 3D-printed and Catphan®500 phantoms
    Abdullah, Kamarul A.
    McEntee, Mark F.
    Reed, Warren M.
    Kench, Peter L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 209 - 214