The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm

被引:0
|
作者
Chul Hwan Park
Joohee Lee
Chisuk Oh
Kyung Hwa Han
Tae Hoon Kim
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital
[2] Yonsei University College of Medicine,Department of Radiology, Research Institute of Radiological Science, Severance Hospital
关键词
Multidetector computed tomography; Iterative model reconstruction; Low tube voltage; Prospective ECG gating; Coronary artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
We evaluated the feasibility of sub-millisievert (mSv) coronary CT angiography (CCTA) using low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm. Twenty-four non-obese healthy subjects (M:F 13:11; mean age 50.2 ± 7.8 years) were enrolled. Three sets of CT images were reconstructed using three different reconstruction methods: filtered back projection (FBP), iterative reconstruction (IR), and knowledge-based iterative model reconstruction (IMR). The scanning parameters were as follows: step-and-shoot axial scanning, 80 kVp, and 200 mAs. On the three sets of CT images, the attenuation and image noise values were measured at the aortic root. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated at the proximal right coronary artery and the left main coronary artery. The qualitative image quality of the CCTA with IMR was assessed using a 4-point grading scale (grade 1, poor; grade 4, excellent). The mean radiation dose of the CCTA was 0.89 ± 0.09 mSv. The attenuation values with IMR were not different from those of other reconstruction methods. The image noise with IMR was significantly lower than with IR and FBP. Compared to FBP, the noise reduction rate of IMR was 69 %. The SNR and CNR of CCTA with IMR were significantly higher than with FBP or IR. On the qualitative analysis with IMR, all included segments were diagnostic (grades 2, 3, and 4), and the mean image quality score was 3.6 ± 0.6. In conclusion, CCTA with low tube voltage, prospective ECG gating, and an IMR algorithm might be a feasible method that allows for sub-millisievert radiation doses and good image quality when used with non-obese subjects.
引用
收藏
页码:197 / 203
页数:6
相关论文
共 50 条
  • [21] Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction
    Iyama, Yuji
    Nakaura, Takeshi
    Kidoh, Masafumi
    Oda, Seitaro
    Utsunomiya, Daisuke
    Sakaino, Naritsugu
    Tokuyasu, Shinichi
    Osakabe, Hirokazu
    Harada, Kazunori
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2016, 23 (11) : 1393 - 1401
  • [22] Combining Coronary with Carotid and Cerebrovascular Angiography Using Prospective ECG Gating and Iterative Reconstruction with 256-slice CT
    Zhang, Jin-Ling
    Liu, Bai-Lu
    Zhao, Yan-Ming
    Liang, Hong-Wei
    Wang, Guo-Kun
    Wan, Yong
    Huang, Ya-Hua
    Shen, Bao-Zhong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (08): : 1291 - 1298
  • [23] Feasibility of a low-dose orbital CT protocol with a knowledge-based iterative model reconstruction algorithm for evaluating Graves' orbitopathy
    Lee, Ho-Joon
    Kim, Jinna
    Kim, Ki Wook
    Lee, Seung-Koo
    Yoon, Jin Sook
    CLINICAL IMAGING, 2018, 51 : 327 - 331
  • [24] Image quality evaluation of iterative model reconstruction on low tube voltage (80 kVp) coronary CT angiography in an animal study
    Hu, Mao-Qing
    Li, Meng
    Liu, Zai-Yi
    Huang, Mei-Ping
    Liu, Hui
    Liang, Chang-Hong
    ACTA RADIOLOGICA, 2016, 57 (02) : 170 - 177
  • [25] Coronary CT Angiography with Knowledge-Based Iterative Model. Reconstruction for Assessing Coronary Arteries and Non-Calcified Predominant Plaques
    Li, Tao
    Tang, Tian
    Yang, Li
    Zhang, Xinghua
    Li, Xueping
    Luo, Chuncai
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (05) : 729 - 738
  • [26] Sub-millisievert Radiation Dose with Retained Image Quality in Patients Undergoing Coronary Computed Tomographic Angiography using 80 kV Tube Voltage: A Prospective Multicenter Multivendor Randomized Trial
    LaBounty, Troy M.
    Leipsic, Jonathon
    Heilbron, Brett
    Mancini, G. B. John
    Gomez, Millie
    Wood, David
    Srichai, Monvadi B.
    Lin, Fay Y.
    Taylor, Carolyn
    Ariaratnam, Nikki
    Weinsaft, Jonathan W.
    Min, James K.
    CIRCULATION, 2010, 122 (21)
  • [27] Feasibility study of iterative model reconstruction combined with low tube voltage, low iodine load, and low iodine delivery rate in craniocervical CT angiography
    Cai, W.
    Hu, C.
    Hu, S.
    Wang, X.
    Gong, J.
    Zhang, W.
    Shi, D.
    Cheng, B.
    CLINICAL RADIOLOGY, 2018, 73 (02) : 217.e1 - 217.e6
  • [28] Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection
    Cha, Min Jae
    Seo, Jae Seung
    Yoo, Dong Soo
    Chong, Semin
    ACTA RADIOLOGICA, 2018, 59 (03) : 280 - 286
  • [29] Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
    Shen, Junlin
    Du, Xiangying
    Guo, Daode
    Cao, Lizhen
    Gao, Yan
    Yang, Qi
    Li, Pengyu
    Liu, Jiabin
    Li, Kuncheng
    PLOS ONE, 2013, 8 (05):
  • [30] Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 941 - 947