The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm

被引:0
|
作者
Chul Hwan Park
Joohee Lee
Chisuk Oh
Kyung Hwa Han
Tae Hoon Kim
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital
[2] Yonsei University College of Medicine,Department of Radiology, Research Institute of Radiological Science, Severance Hospital
关键词
Multidetector computed tomography; Iterative model reconstruction; Low tube voltage; Prospective ECG gating; Coronary artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
We evaluated the feasibility of sub-millisievert (mSv) coronary CT angiography (CCTA) using low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm. Twenty-four non-obese healthy subjects (M:F 13:11; mean age 50.2 ± 7.8 years) were enrolled. Three sets of CT images were reconstructed using three different reconstruction methods: filtered back projection (FBP), iterative reconstruction (IR), and knowledge-based iterative model reconstruction (IMR). The scanning parameters were as follows: step-and-shoot axial scanning, 80 kVp, and 200 mAs. On the three sets of CT images, the attenuation and image noise values were measured at the aortic root. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated at the proximal right coronary artery and the left main coronary artery. The qualitative image quality of the CCTA with IMR was assessed using a 4-point grading scale (grade 1, poor; grade 4, excellent). The mean radiation dose of the CCTA was 0.89 ± 0.09 mSv. The attenuation values with IMR were not different from those of other reconstruction methods. The image noise with IMR was significantly lower than with IR and FBP. Compared to FBP, the noise reduction rate of IMR was 69 %. The SNR and CNR of CCTA with IMR were significantly higher than with FBP or IR. On the qualitative analysis with IMR, all included segments were diagnostic (grades 2, 3, and 4), and the mean image quality score was 3.6 ± 0.6. In conclusion, CCTA with low tube voltage, prospective ECG gating, and an IMR algorithm might be a feasible method that allows for sub-millisievert radiation doses and good image quality when used with non-obese subjects.
引用
收藏
页码:197 / 203
页数:6
相关论文
共 50 条
  • [1] The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm
    Park, Chul Hwan
    Lee, Joohee
    Oh, Chisuk
    Han, Kyung Hwa
    Kim, Tae Hoon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 197 - 203
  • [2] Sub-millisievert CT colonography: effect of knowledge-based iterative reconstruction on the detection of colonic polyps
    Kang, Hyo-Jin
    Kim, Se Hyung
    Shin, Cheong-Il
    Joo, Ijin
    Ryu, Hwaseong
    Kim, Sang Gyun
    Im, Jong Pil
    Han, Joon Koo
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5258 - 5266
  • [3] Sub-millisievert CT colonography: effect of knowledge-based iterative reconstruction on the detection of colonic polyps
    Hyo-Jin Kang
    Se Hyung Kim
    Cheong-Il Shin
    Ijin Joo
    Hwaseong Ryu
    Sang Gyun Kim
    Jong Pil Im
    Joon Koo Han
    European Radiology, 2018, 28 : 5258 - 5266
  • [4] A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn’s disease
    Siobhan B O’Neill
    Patrick D Mc Laughlin
    Lee Crush
    Owen J O’Connor
    Sebastian R Mc Williams
    Orla Craig
    Anne Marie Mc Garrigle
    Fiona O’Neill
    Jackie Bye
    Max F. Ryan
    Fergus Shanahan
    Michael M Maher
    European Radiology, 2013, 23 : 2503 - 2512
  • [5] A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn's disease
    O'Neill, Siobhan B.
    Mc Laughlin, Patrick D.
    Crush, Lee
    O'Connor, Owen J.
    Mc Williams, Sebastian R.
    Craig, Orla
    Mc Garrigle, Anne Marie
    O'Neill, Fiona
    Bye, Jackie
    Ryan, Max F.
    Shanahan, Fergus
    Maher, Michael M.
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2503 - 2512
  • [6] Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
    Wang, Xinrui
    Zhu, Chengcheng
    Li, Jing
    Degnan, Andrew J.
    Jiang, Tao
    Lu, Jianping
    MEDICINE, 2018, 97 (30)
  • [7] Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction
    Wei-Hua Yin
    Bin Lu
    Zhi-Hui Hou
    Nan Li
    Lei Han
    Yong-Jian Wu
    Hong-Xia Niu
    Justin R. Silverman
    Carlo Nicola De Cecco
    U. Joseph Schoepf
    European Radiology, 2013, 23 : 2927 - 2933
  • [8] Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction
    Yin, Wei-Hua
    Lu, Bin
    Hou, Zhi-Hui
    Li, Nan
    Han, Lei
    Wu, Yong-Jian
    Niu, Hong-Xia
    Silverman, Justin R.
    De Cecco, Carlo Nicola
    Schoepf, U. Joseph
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 2927 - 2933
  • [9] Usefulness of a Low Tube Voltage: Knowledge-Based Iterative Model Reconstruction Algorithm for Computed Tomography Venography
    Iyama, Yuji
    Nakaura, Takeshi
    Iyama, Ayumi
    Kidoh, Masafumi
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (05) : 811 - 816
  • [10] Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Muzaffer Saglam
    Ersin Ozturk
    Kemal Kara
    Japanese Journal of Radiology, 2015, 33 : 46 - 47