An Experimental Determination of a Real Fire Performance of a Non-Load Bearing Glass Wall Assembly

被引:0
|
作者
Samuel L. Manzello
Richard G. Gann
Scott R. Kukuck
Kuldeep R. Prasad
Walter W. Jones
机构
[1] National Institute of Standards and Technology (NIST),Building and Fire Research Laboratory (BFRL)
[2] US Army Research Laboratory,Weapons and Materials Research Directorate
来源
Fire Technology | 2007年 / 43卷
关键词
glass partition; glass breakage;
D O I
暂无
中图分类号
学科分类号
摘要
A glass wall assembly was exposed to an intense real-scale compartment fire. The wall assembly consisted of four glass sections, two of which were fitted with tempered double-pane glass and the other two sections were fitted with tempered single-pane glass. At each glass section, temperatures were measured at the exposed face and the unexposed face. Total heat flux gauges were used to measure both the temporal variation of the energy incident on the glass wall and the transmitted energy rate detected through two of the glass sections. Visual and infrared cameras were used to image the unexposed face of each wall assembly during the fire exposure. Results of glass breakage and subsequent glass fall out were compared to studies in the literature for glass sections exposed to compartment fires. The behavior of the glass wall assembly under a fire load is presented.
引用
收藏
页码:77 / 89
页数:12
相关论文
共 50 条
  • [41] Design and production of sustainable lightweight concrete precast sandwich panels for non-load bearing partition walls
    Moutassem, Fayez
    Al Amara, Kadhim
    COGENT ENGINEERING, 2021, 8 (01):
  • [42] Experimental analysis of Interlocking Load Bearing Wall Brickool System
    Osman, S. A.
    Mohamed, Zawawi Samba
    Sulaiman, A. R.
    Ismail, M. Fikri
    ADVANCED MATERIALS ENGINEERING AND TECHNOLOGY II, 2014, 594-595 : 439 - +
  • [43] Determination of notch factors for transverse non-load carrying stiffeners based on numerical analysis and metamodeling
    Neuhaeusler, Josef
    Rother, Klemens
    WELDING IN THE WORLD, 2022, 66 (04) : 753 - 766
  • [44] Fire Resilience of Load-Bearing Wall Made of Hollow Timber Elements
    Perkovic, Nikola
    Rajcic, Vlatka
    Barbalic, Jure
    FIRE-SWITZERLAND, 2024, 7 (12):
  • [45] SIMULATION OF A COMPARTMENT FIRE EFFECT ON A LOAD- BEARING WALL MADE OF STRAW
    Terenova, Ludmila
    Spilak, Dominik
    Dubravska, Katarina
    Stefkova, Jaroslava
    ACTA FACULTATIS XYLOLOGIAE ZVOLEN, 2024, 66 (01):
  • [46] Improving Electrospun Fibre Stacking with Direct Writing for Developing Scaffolds for Tissue Engineering for Non-load Bearing Bone
    Blackwood, K. A.
    Ristovski, N.
    Liao, S.
    Bock, N.
    Ren, J.
    Kirby, G. T. S.
    Stevens, M. M.
    Steck, R.
    Woodruff, M. A.
    5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING IN VIETNAM, 2015, 46 : 125 - 128
  • [47] Fire performance of non-load-bearing light-gauge slotted steel stud walls
    Liu, Faqi
    Fu, Feng
    Wang, Yuyin
    Liu, Qiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 137 : 228 - 241
  • [48] OPTIMIZATION OF COMPRESSIVE STRENGTH OF WASTED SOFT DRINK CAN FIBER NON-LOAD BEARING CONCRETE HOLLOW BLOCKS
    Sambrano, Johnson P.
    Estores, Gilford B.
    INTERNATIONAL JOURNAL OF GEOMATE, 2022, 22 (94): : 135 - 142
  • [49] Load bearing performance of weathered laminated safety glass panes
    Ensslen, Frank
    STAHLBAU, 2007, 76 (08) : 582 - 590
  • [50] Experimental and numerical study on load-bearing performance in triple-glazed insulating glass units
    Wang, Zhiyuan
    Liu, Junjin
    Li, Dian
    Yang, Kexin
    Chen, Meihe
    Wang, Chao
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 418