An Experimental Determination of a Real Fire Performance of a Non-Load Bearing Glass Wall Assembly

被引:0
|
作者
Samuel L. Manzello
Richard G. Gann
Scott R. Kukuck
Kuldeep R. Prasad
Walter W. Jones
机构
[1] National Institute of Standards and Technology (NIST),Building and Fire Research Laboratory (BFRL)
[2] US Army Research Laboratory,Weapons and Materials Research Directorate
来源
Fire Technology | 2007年 / 43卷
关键词
glass partition; glass breakage;
D O I
暂无
中图分类号
学科分类号
摘要
A glass wall assembly was exposed to an intense real-scale compartment fire. The wall assembly consisted of four glass sections, two of which were fitted with tempered double-pane glass and the other two sections were fitted with tempered single-pane glass. At each glass section, temperatures were measured at the exposed face and the unexposed face. Total heat flux gauges were used to measure both the temporal variation of the energy incident on the glass wall and the transmitted energy rate detected through two of the glass sections. Visual and infrared cameras were used to image the unexposed face of each wall assembly during the fire exposure. Results of glass breakage and subsequent glass fall out were compared to studies in the literature for glass sections exposed to compartment fires. The behavior of the glass wall assembly under a fire load is presented.
引用
收藏
页码:77 / 89
页数:12
相关论文
共 50 条
  • [21] Flexural strength characteristics of non-load bearing masonry walls in Kuwait
    Moneera Al-Shaleh
    Emmanuel K. Attiogbe
    Materials and Structures, 1997, 30 : 277 - 283
  • [22] Flexural strength characteristics of non-load bearing masonry walls in Kuwait
    Kuwait Inst for Scientific Research, Kuwait
    Mater Struct, 199 (277-283):
  • [23] A determination of load and non-load shares of highway pavement routine maintenance expenditures
    Purdue University, School of Civil Engineering, 1284 Civil Engineering Building, West Lafayette, IN 47907-1284, United States
    Road and Transport Research, 2002, 11 (02): : 3 - 13
  • [24] Full-Scale Standard Fire Experiment and Numerical Modelling Behaviour of Non-Load Bearing Calcium Silicate Partition Drywall
    Lin, Ching-Yuan
    Wang Yinuo
    Chuang, Ying-Ji
    2018 3RD INTERNATIONAL CONFERENCE ON BUILDING MATERIALS AND CONSTRUCTION (ICBMC 2018), 2018, 371
  • [25] Fire tests of non-load bearing light gauge steel frame walls lined with calcium silicate boards and gypsum plasterboards
    Ariyanayagam, Anthony Deloge
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2017, 115 : 86 - 99
  • [26] Designing of porous PMMA/diopside bone cement for non-load bearing applications
    Choudhary, Rajan
    Venkatraman, Senthil Kumar
    Bulygina, Inna
    Senatov, Fedor
    Kaloshkin, Sergey
    Swamiappan, Sasikumar
    JOURNAL OF ASIAN CERAMIC SOCIETIES, 2020, 8 (03): : 862 - 872
  • [27] Non-load Bearing inner Partition Walls in solid Construction - References for Planning and Execution
    Schroeder, Olaf
    MAUERWERK, 2008, 12 (01) : 28 - +
  • [28] Fire performance of load bearing LSF wall systems made of low strength steel studs
    Ariyanayagam, Anthony Deloge
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2018, 130 : 487 - 504
  • [29] Fire resistance of hollow load-bearing wall tile
    Ingberg, SH
    Foster, HD
    BUREAU OF STANDARDS JOURNAL OF RESEARCH, 1929, 2 (01): : 1 - 334
  • [30] Application of Concepts of Fire Resistance of Load Bearing Structural Glass
    Sjostrom, Johan
    Lange, David
    Debuyser, Michael
    Honfi, Daniel
    Sonck, Delphine
    Belts, Jan
    STRUCTURES IN FIRE, 2016, : 869 - 876