An Experimental Determination of a Real Fire Performance of a Non-Load Bearing Glass Wall Assembly

被引:0
|
作者
Samuel L. Manzello
Richard G. Gann
Scott R. Kukuck
Kuldeep R. Prasad
Walter W. Jones
机构
[1] National Institute of Standards and Technology (NIST),Building and Fire Research Laboratory (BFRL)
[2] US Army Research Laboratory,Weapons and Materials Research Directorate
来源
Fire Technology | 2007年 / 43卷
关键词
glass partition; glass breakage;
D O I
暂无
中图分类号
学科分类号
摘要
A glass wall assembly was exposed to an intense real-scale compartment fire. The wall assembly consisted of four glass sections, two of which were fitted with tempered double-pane glass and the other two sections were fitted with tempered single-pane glass. At each glass section, temperatures were measured at the exposed face and the unexposed face. Total heat flux gauges were used to measure both the temporal variation of the energy incident on the glass wall and the transmitted energy rate detected through two of the glass sections. Visual and infrared cameras were used to image the unexposed face of each wall assembly during the fire exposure. Results of glass breakage and subsequent glass fall out were compared to studies in the literature for glass sections exposed to compartment fires. The behavior of the glass wall assembly under a fire load is presented.
引用
收藏
页码:77 / 89
页数:12
相关论文
共 50 条
  • [1] An experimental determination of a real fire performance of a non-load bearing glass wall assembly
    Manzello, Samuel L.
    Gann, Richard G.
    Kukuck, Scott R.
    Prasad, Kuldeep R.
    Jones, Walter W.
    FIRE TECHNOLOGY, 2007, 43 (01) : 77 - 89
  • [2] Experimental studies of non-load bearing steel wall systems under fire conditions
    Kolarkar, Prakash
    Mahendran, Mahen
    FIRE SAFETY JOURNAL, 2012, 53 : 85 - 104
  • [3] Fire performance of steel and plasterboard sheathed non-load bearing LSF walls
    Dias, Yomal
    Keerthan, Poologanathan
    Mahendran, Mahen
    FIRE SAFETY JOURNAL, 2019, 103 : 1 - 18
  • [4] Experimental study of non-load bearing light gauge steel framed walls in fire
    Ariyanayagam, Anthony Deloge
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 145 : 529 - 551
  • [5] Experimental study on the performance of a load-bearing steel stud gypsum board wall assembly exposed to a real fire
    Park, Seul-Hyun
    Manzello, Samuel L.
    Bundy, Matthew F.
    Mizukami, Tensei
    FIRE SAFETY JOURNAL, 2011, 46 (08) : 497 - 505
  • [6] Experimental and Numerical Analysis for Non-Load Bearing Sandwich Wall Panels for Blast Mitigation
    El-Sisi, A. E.
    Saucier, A.
    Salim, H. A.
    Nawar, M.
    STRUCTURES CONGRESS 2017: BLAST, IMPACT LOADING, AND RESPONSE OF STRUCTURES, 2017, : 77 - 85
  • [7] NON-LOAD BEARING PARTITIONS
    GROVER, R
    RIBA JOURNAL-ROYAL INSTITUTE OF BRITISH ARCHITECTS, 1985, 92 (01): : 69 - 69
  • [8] Experimental study on non-load bearing multi-span sandwich wall panels for blast mitigation
    Elbelbisi, Ahmed
    El-Sisi, Alaa
    Elgholmy, Lamies
    Helal, Zinab
    Elemam, Hesham
    Saucier, Aaron
    Salim, Hani
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [9] Fire resistance of composite non-load bearing light steel framing walls
    Khetata, Seddik M.
    Piloto, Paulo A. G.
    Gavilan, Ana B. R.
    JOURNAL OF FIRE SCIENCES, 2020, 38 (02) : 136 - 155
  • [10] Fire resistance of non-load bearing LSF walls with varying cavity depth
    Magarabooshanam, Harikrishnan
    Ariyanayagam, Anthony
    Mahendran, Mahen